Displaying all 6 publications

Abstract:
Sort:
  1. Al-Atabi M, Chin SB, Luo XY
    J Biomech Eng, 2010 Apr;132(4):041003.
    PMID: 20387966 DOI: 10.1115/1.4001043
    Three-dimensional scaled-up transparent models of three human cystic ducts were prepared on the basis of anatomical specimens. The measurement of pressure drop across the cystic duct models and visualization of the flow structures within these ducts were performed at conditions replicating the physiological state. The flow visualization study confirmed the laminar nature of the flow of bile inside the cystic duct and values of pressure drop coefficient (Cp) decreased as the Reynolds number (Re) increased. The three tested models showed comparable behavior for the curve of Reynolds number versus the pressure drop coefficient. The results show that the tested cystic ducts have both increased pressure drop and complicated flow structures when compared with straight conduits. High resistance in a cystic duct may indicate that the gallbladder has to exert large force in expelling bile to the cystic duct. For patients with diseased gallbladder, and even in healthy persons, gallbladder is known to stiffen with age and it may lose its compliance or flexibility. A high resistance cystic duct coupled with a stiffened gallbladder may result in prolonged stasis of bile in the gallbladder, which is assumed to encourage the formation of gallstones.
  2. Lee HW, Arunasalam P, Laratta WP, Seetharamu KN, Azid IA
    J Biomech Eng, 2007 Aug;129(4):540-7.
    PMID: 17655475
    In this study, a hybridized neuro-genetic optimization methodology realized by embedding finite element analysis (FEA) trained artificial neural networks (ANN) into genetic algorithms (GA), is used to optimize temperature control in a ceramic based continuous flow polymerase chain reaction (CPCR) device. The CPCR device requires three thermally isolated reaction zones of 94 degrees C, 65 degrees C, and 72 degrees C for the denaturing, annealing, and extension processes, respectively, to complete a cycle of polymerase chain reaction. The most important aspect of temperature control in the CPCR is to maintain temperature distribution at each reaction zone with a precision of +/-1 degree C or better, irrespective of changing ambient conditions. Results obtained from the FEA simulation shows good comparison with published experimental work for the temperature control in each reaction zone of the microfluidic channels. The simulation data are then used to train the ANN to predict the temperature distribution of the microfluidic channel for various heater input power and fluid flow rate. Once trained, the ANN analysis is able to predict the temperature distribution in the microchannel in less than 20 min, whereas the FEA simulation takes approximately 7 h to do so. The final optimization of temperature control in the CPCR device is achieved by embedding the trained ANN results as a fitness function into GA. Finally, the GA optimized results are used to build a new FEA model for numerical simulation analysis. The simulation results for the neuro-genetic optimized CPCR model and the initial CPCR model are then compared. The neuro-genetic optimized model shows a significant improvement from the initial model, establishing the optimization method's superiority.
  3. Dabirrahmani D, Bokor D, Tarento T, Ahmad S, Appleyard R
    J Biomech Eng, 2019 Oct 01;141(10).
    PMID: 31175841 DOI: 10.1115/1.4043969
    As the use of glenoid suture anchors in arthroscopic and open reconstruction, for instability after Bankart lesions of the shoulder, increases, an emerging problem has been the incidence of glenoid rim fractures through suture drill holes. Very little is known regarding the effect of the Hill-Sachs lesion on the glenoid's susceptibility to fracture and how drill hole location can further affect this. This study used finite element modeling techniques to investigate the risk of fracture of the glenoid rim in relation to variable sized Hill-Sachs defects impacting on the anterior glenoid edge with suture anchor holes placed in varying positions. The distribution of Von Mises (VM) stresses and the factor of safety (FOS) for each of the configurations were calculated. The greatest peak in VM stresses was generated when the glenoid was loaded with a small Hill-Sachs lesion. The VM stresses were lessened and the FOS increased (reducing likelihood of failure) with increasing size of the Hill-Sachs lesion. Placement of the suture drill holes at 2 mm from the glenoid rim showed the highest risk of failure; and when combined with a medium sized Hill-Sachs lesion, which matched the central line of the drill holes, a potentially clinically significant configuration was presented. The results of this study are useful in assisting the surgeon in understanding the interaction between the Hill-Sachs lesion size and the placement of suture anchors with the purpose of minimizing the risk of subsequent rim fracture with new injury.
  4. Yap YT, Gouwanda D, Gopalai AA, Chong YZ
    J Biomech Eng, 2023 Feb 01;145(2).
    PMID: 36082472 DOI: 10.1115/1.4055564
    Musculoskeletal modeling and simulation have been an emerging trend in human gait analysis. It allows the user to isolate certain biomechanical conditions and elucidate the dynamics of joints and muscles. This study used an open-source musculoskeletal modeling and simulation tool, opensim to investigate the biomechanical effect of knee brace. It collected gait data from thirty-eight participants and examined the gait spatio-temporal parameters, joint angles, and joint moments. Static optimization was performed to estimate the lower extremity muscle force. Statistical analysis was conducted to identify the difference between normal and braced gaits. The results demonstrated the feasibility of this method to investigate the interaction and coordination of lower extremity joints and muscles. The knee brace constrained the range of the motion of the knee during walking. It also changed the walking speed, step length, and stance-to-swing ratio. Several significant differences were found in the joint moments and muscle forces of the rectus femoris, gastrocnemius, soleus and tibialis anterior. Musculoskeletal modeling and simulation tool offers a less invasive and practical alternative to analyze human motion. It also provides a means to investigate the effect of medical devices such as knee brace, which can be potentially beneficial for the future design and development of such devices and for the derivation of future rehabilitation treatment to improve patient's gait.
  5. Talib I, Sundaraj K, Lam CK
    J Biomech Eng, 2021 Jan 01;143(1).
    PMID: 32691054 DOI: 10.1115/1.4047850
    This study analyzed the crosstalk in mechanomyographic (MMG) signals from elbow flexors during isometric muscle actions from 20% to 100% maximum voluntary isometric contraction (MVIC). Twenty-five young, healthy, male participants performed the isometric elbow flexion, forearm pronation, and supination tasks at an elbow joint angle of 90 deg. The MMG signals from the biceps brachii (BB), brachialis (BRA), and brachioradialis (BRD) muscles were recorded using accelerometers. The cross-correlation coefficient was used to quantify the crosstalk in MMG signals, recorded in a direction transverse to muscle fiber axis, among the muscle pairs (P1: BB and BRA, P2: BRA and BRD, and P3: BB and BRD). In addition, the MMG RMS and MPF were quantified. The mean normalized RMS and mean MPF exhibited increasing (r > 0.900) and decreasing (r 
  6. Tan WT, Liew YM, Mohamed Mokhtarudin MJ, Pirola S, Wan Ab Naim WN, Amry Hashim S, et al.
    J Biomech Eng, 2021 Aug 01;143(8).
    PMID: 33764388 DOI: 10.1115/1.4050642
    A computational approach is used to investigate potential risk factors for distal stent graft-induced new entry (dSINE) in aortic dissection (AD) patients. Patient-specific simulations were performed based on computed tomography images acquired from six AD patients (three dSINE and three non-dSINE) to analyze the correlation between anatomical characteristics and stress/strain distributions. Sensitivity analysis was carried out using idealized models to independently assess the effect of stent graft length, stent tortuosity and wedge apposition angle at the landing zone on key biomechanical variables. Mismatch of biomechanical properties between the stented and nonstented regions led to high stress at the distal stent graft-vessel interface in all patients, as well as shear strain in the neighboring region, which coincides with the location of tear formation. Stress was observed to increase with the increase of stent tortuosity (from 263 kPa at a tortuosity angle of 50 deg to 313 kPa at 30 deg). It was further amplified by stent graft landing at the inflection point of a curve. Malapposition of the stent graft led to an asymmetrical segment within the aorta, therefore changing the location and magnitude of the maximum von Mises stress substantially (up to +25.9% with a +25 deg change in the distal wedge apposition angle). In conclusion, stent tortuosity and wedge apposition angle serve as important risk predictors for dSINE formation in AD patients.