Displaying all 4 publications

Abstract:
Sort:
  1. Khan ESKBM, Thean CAP, Zakaria ZB, Awang MSB, Karupiah RK, Awang MB
    J Orthop Case Rep, 2020;10(2):101-105.
    PMID: 32953668 DOI: 10.13107/jocr.2020.v10.i02.1718
    Introduction: Spinal schwannoma can occur anywhere along the spinal cord but is predominantly seen in the cervical and thoracic region.It composes mainly of well-differentiated schwann cell and is benign in nature. It is typically seen in the peripheral nerves and is commonly associated with neurofibromatosis. Up to 80% of cases, spinal schwannoma is reported to be intradural in location and 15% of cases have both intradural and extradural components. Spinal schwannoma rarely causes conus medullaris syndrome.

    Case Report: In this case series, all three female patients in their 4th and 5th decades of life presented with conus medullaris syndrome. Lower back pain, radiculopathy, lower limb weakness, and urinary incontinence are their main clinical presentation. Magnetic resonance imaging shows a well-defined intradural, extramedullary mass compressing onto the conus medullary region. These patients undergone microscopic assisted excision of the tumor and had remarkably good early outcome despite the advanced presentation of neurological deficit.

    Conclusion: Despite the late presentation with significant neurological deficit, surgical excision of spinal schwannomas carries a good prognosis postoperatively due to their benign nature and extramedullary location.

  2. Charles APT, Shukrimi BA, Zamzuri BZ, Ardilla HBAR
    J Orthop Case Rep, 2021 5 7;10(3):108-113.
    PMID: 33954149 DOI: 10.13107/jocr.2020.v10.i03.1772
    Introduction: The prevalence of knee osteoarthritis is on the raise. This raise has been a huge financial burden to developed countries in treating the disease. Transcutaneous electrical nerve stimulation (TENS) is a cost-effective, easily available, and self-applicable mode of non-pharmacological pain relieve technique. Despite these advantages, the use, settings, and effectiveness of portable TENS are still poorly understood. The aim of this study is to determine the effectiveness of portable TENS at different frequencies in treating knee osteoarthritis.

    Materials and Methods: This is a single-center quasi-experimental study involving 100 patients seen in the outpatient department with knee osteoarthritis. They were randomly (computer generated) allocated into two arms (high frequency [H-F] or low frequency [L-F]). H-F is set at 100 Hz and L-F is set at 4 Hz. A baseline assessment is taken with the visual analog score (VAS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score, and Lequesne index. They were instructed to self-administer the TENS therapy as per protocol and followed up at the 4th and 12th week to be reevaluated on the above scores.

    Results: The final results show that both H-F and L-F groups showed improvement in all parameters of the VAS, WOMAC index, Oxford Knee Score, and Lequesne index (73%). Only the pain component of Lequesne index, activities of daily living component of Lequesne index, total Lequesne index, and pain component of WOMAC index shows a statistically significant difference, favoring the H-F group. The H-F group yields a faster result; however, with time the overall effect remains the same in both groups.

    Conclusion: Both H-F and L-F groups show improvement in all the component of Lequesne index, Oxford Knee Score, WOMAC index, and VAS with no statistical difference between the two groups. Although H-F yields a faster result, not everyone is able to tolerate the intensity. Therefore, the selection of H-F or L-F should be done on case basis depending on the severity of symptoms, patient's expectation, and patient's ability to withstand the treatment therapy. Based on this 12th week follow-up, both groups will continue to improve with time. A longer study should be conducted to see it this improvement will eventually plateau off or continue to improve until the patient is symptom free.

  3. Kow RY, Mustapha Zakaria Z, Khan ESKM, Low C
    J Orthop Case Rep, 2019 3 28;8(6):65-67.
    PMID: 30915298 DOI: 10.13107/jocr.2250-0685.1262
    Introduction: Fracture of the ulnar coronoid process is uncommon. It is commonly associated with posterior dislocation of the elbow, but it may also present as an isolated fracture. In general, all ulnar coronoid process fractures with elbow joint instability and large fracture fragments are fixed surgically. We report two cases of the rare isolated Regan-Morrey type III ulnar coronoid process fractures and their outcomes.

    Case Report: Case Report 1: Mrs P, a 27-year-old right-hand dominant female, was involved in a motor vehicle accident (MVA) and sustained an isolated Regan-Morrey type III ulnar coronoid process fracture. In view of the large coronoid process fragment causing elbow joint instability, she underwent an open reduction and internal fixation when the elbow swelling had subsided. An anterior approach was used to identify the fracture fragment and it was fixed with two half-threaded cancellous lag screws with washers to achieve an anatomical reduction. Postoperatively, she recovered with excellent outcome based on the Mayo elbow performance score (MEPS).Case Report 2: Mr M, a 23-year-old right-hand dominant gentleman, was involved in a MVA and sustained an isolated Regan-Morrey type III ulnar coronoid process fracture. During examination under general anesthesia, passive range of the movement of his right elbow was noted to be <90°due to the impaction of the fracture fragment. An open reduction through an anterior approach was performed and Kirschner wires were inserted to fix the coronoid process fracture. Kirschner wires were opted for the ease of post-operative removal as the patient was not keen to have a retained implant after recovery. He recovered with good outcome based on the MEPS.

    Conclusion: Isolated fracture of the ulnar coronoid process is rare. Open reduction and internal fixation is mandatory for patients with coronoid process fracture and unstable elbow joint to achieve good functional outcomes.

  4. Subramaniam KAL, Liang TS, Hao PZ, Senan NAF, Amin MZBHM, Jain M
    J Orthop Case Rep, 2024 Mar;14(3):141-145.
    PMID: 38560322 DOI: 10.13107/jocr.2024.v14.i03.4320
    INTRODUCTION: Distal junctional failure (DJF) is underreported when compared to proximal junctional failure. DJF arising due to spondylodiscitis has never been reported in the literature.

    CASE REPORT: A 45-year-old lady with a body mass index of 33 presented with a long-standing inability to walk due to myelopathy secondary to continuous ossified posterior longitudinal ligament and ossified ligamentum flavum. Posterior fusion and laminectomy were done from D2 to L2. She had an initial wound breakdown with a surgical site infection, but after 6 weeks, she developed spondylodiscitis at the distal instrumented vertebra, leading to DJF. She was started on appropriate antibiotics and an extension of fusion.

    CONCLUSION: This report demonstrates and discusses the management of a rare case of DJF arising due to spondylodiscitis of the last instrumented vertebra.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links