  1. Zainal Abidin I, Syed Tamin S, Huat Tan L, Chong WP, Azman W
    Pacing Clin Electrophysiol, 2007 Nov;30(11):1420-2.
    PMID: 17976112
    Infection is a relatively rare but devastating complication of intracardiac device implantation. Burkholderia pseudomallei is the organism which causes melioidosis, an endemic and lethal infection in the tropics. We describe a case of pacemaker infection secondary to Burkholderia pseudomallei, which was treated by explantation of the device and appropriate antimicrobial therapy.
  2. Tamin SS, Hussin A, Za I, Halmey N, Azman W
    Pacing Clin Electrophysiol, 2007 Feb;30(2):276-9.
    PMID: 17338728
    Coronary sinus perforation is a relatively uncommon but much feared complication that may occur during the placement of left ventricular pacing lead. Coronary sinus perforation, especially in the presence of an obstructive flap, usually indicates the need to abandon the implantation attempt, as there are difficulties in crossing the obstructive flap as well as uncertainty of whether the lead is in the true lumen or into the pericardial space. We describe our experience in successfully placing the left ventricular lead safely despite the problems arising from these circumstances.
  3. Singh B, Zhang S, Ching CK, Huang D, Liu YB, Rodriguez DA, et al.
    Pacing Clin Electrophysiol, 2018 12;41(12):1619-1626.
    PMID: 30320410 DOI: 10.1111/pace.13526
    BACKGROUND: Despite available evidence that implantable cardioverter defibrillators (ICDs) reduce all-cause mortality among patients at risk for sudden cardiac death, utilization of ICDs is low especially in developing countries.

    OBJECTIVE: To summarize reasons for ICD or cardiac resynchronization therapy defibrillator implant refusal by patients at risk for sudden cardiac arrest (Improve SCA) in developing countries.

    METHODS: Primary prevention (PP) and secondary prevention (SP) patients from countries where ICD use is low were enrolled. PP patients with additional risk factors (syncope, ejection fraction 

  4. Lin AC, Biffi M, Exner DV, Johnson WB, Gras D, Hussin A, et al.
    PMID: 29808920 DOI: 10.1111/pace.13389
    BACKGROUND: Steroid-eluting (SE) electrodes suppress local inflammation and lower pacing capture thresholds (PCT); however, their effectiveness on quadripolar left ventricular (LV) leads in the cardiac vein is not fully studied. We evaluated the effectiveness of SE on all four LV pacing electrodes in human subjects enrolled in the Medtronic Attain® Performa™ quadripolar LV lead study.

    METHODS: A total of 1,097 subjects were included in this evaluation. At each follow-up visit (1, 3, 6, and 12 months), LV PCT and pacing impedance were measured using either manual or automated testing methods. Summary statistics for PCT and impedance values were obtained for implant and each scheduled follow-up visit for all lead models.

    RESULTS: Average extended bipolar (LV electrode to right ventricular Coil) PCTs for the four LV SE pacing electrodes (LV1, LV2, LV3, and LV4) on the three shapes of the quadripolar LV leads were 1.06 ± 0.97 V, 1.38 ± 1.26 V, 1.51 ± 1.33 V, and 2.25 ± 1.63 V, respectively, at 0.5-ms pulse width. PCTs remained low and stable throughout the 12-month follow-up period.

    CONCLUSION: This clinical trial demonstrated that SE on all LV pacing electrodes is associated with low and stable PCTs for all quadripolar LV lead electrodes, resulting in multiple viable vectors for LV pacing. The large number of available vectors facilitates basal pacing, avoidance of PNS, and potentially prolongs generator longevity due to lower PCTs.