Displaying publications 1 - 20 of 454 in total

Abstract:
Sort:
  1. Chan LL, Mak JW, Low YT, Koh TT, Ithoi I, Mohamed SM
    Acta Trop, 2011 Jan;117(1):23-30.
    PMID: 20858455 DOI: 10.1016/j.actatropica.2010.09.004
    During a study on the quality of the indoor environment, Acanthamoeba spp. were detected in 20 out of 87 dust samples collected from air-conditioners installed in a four-story campus building located in Kuala Lumpur, Malaysia. Twenty-one cloned Acanthamoeba isolates designated as IMU1 to IMU21 were established from the positive primary cultures. Five species were identified from the 16 isolates according to the morphological criteria of Pussard and Pons; i.e. A. castellanii, A. culbertsoni, A. griffini, A. hatchetti and A. polyphaga. Species identities for the remaining five isolates (IMU4, IMU5, IMU15, IMU20 and IMU21), however, could not be determined morphologically. At genotypic characterization, these isolates were placed into T3 (IMU14); T5 (IMU16 and IMU17) and T4 (all the remaining isolates). To predict the potential pathogenicity of these Acanthamoeba isolates, thermo- and osmotolerance tests were employed; many isolates were predicted as potential human pathogens based on the outcome of these tests. This is the first time potentially pathogenic Acanthamoeba have been isolated from air-conditioners in Malaysia.
    Matched MeSH terms: Air Conditioning*
  2. Hashim SM, Mohamed AR, Bhatia S
    Adv Colloid Interface Sci, 2010 Oct 15;160(1-2):88-100.
    PMID: 20813344 DOI: 10.1016/j.cis.2010.07.007
    There has been tremendous progress in membrane technology for gas separation, in particular oxygen separation from air in the last 20 years. It provides an alternative route to the existing conventional separation processes such as cryogenic distillation and pressure swing adsorption as well as cheaper production of oxygen with high purity. This review presents the recent advances of ceramic membranes for the separation of oxygen from air at high temperature. It covers the issues and problems with respect to the selectivity and separation performance. The paper also presents different approaches applied to overcome these challenges. The future directions of ceramic-based membranes for oxygen separation from air are also presented.
    Matched MeSH terms: Air/analysis*
  3. Azmi SZ, Latif MT, Ismail AS, Juneng L, Jemain AA
    Air Qual Atmos Health, 2010 Mar;3(1):53-64.
    PMID: 20376168
    Over the last decades, the development of the Klang Valley (Malaysia), as an urban commercial and industrial area, has elevated the risk of atmospheric pollutions. There are several significant sources of air pollutants which vary depending on the background of the location they originate from. The aim of this study is to determine the trend and status of air quality and their correlation with the meteorological factors at different air quality monitoring stations in the Klang Valley. The data of five major air pollutants (PM(10), CO, SO(2), O(3), NO(2)) were recorded at the Alam Sekitar Sdn Bhd (ASMA) monitoring stations in the Klang Valley, namely Petaling Jaya (S1), Shah Alam (S2) and Gombak (S3). The data from these three stations were compared with the data recorded at Jerantut, Pahang (B), a background station established by the Malaysian Department of Environment. Results show that the concentrations of CO, NO(2) and SO(2) are higher at Petaling Jaya (S1) which is due to influence of heavy traffic. The concentrations of PM(10) and O(3,) however, are predominantly related to regional tropical factors, such as the influence of biomass burning and of ultra violet radiation from sunlight. They can, though, also be influenced by local sources. There are relatively stronger inter-pollutant correlations at the stations of Gombak and Shah Alam, and the results also suggest that heavy traffic flow induces high concentrations of PM(10), CO, NO(2) and SO(2) at the three sampling stations. Additionally, meteorological factors, particularly the ambient temperature and wind speed, may influence the concentration of PM(10) in the atmosphere.
    Matched MeSH terms: Air Pollutants; Air Pollution
  4. Ahmad NL, Norsidah AM
    Anaesth Intensive Care, 2001 Oct;29(5):510-4.
    PMID: 11669433
    In this prospective, randomized controlled trial, changes in endotracheal tube cuff pressure were studied in 60 patients undergoing elective surgery under general anaesthesia with nitrous oxide and oxygen. The cuffs were inflated with either air or distilled water. The mean pressure in the air-filled cuffs increased steadily throughout the procedure, reaching 47.5 +/- 7.3 cmH2O at one hour compared with 31.6 +/- 2.4 cmH2O mean pressure in the water-filled cuffs. The pressure and the rate of rise in cuff pressure were significantly lower (P<0.05) in the water-filled cuffs throughout the hour of study. When an endotracheal tube cuff is distended with water, the rise in cuff pressure during nitrous oxide anaesthesia is lower than that of an air-filled cuff.
    Matched MeSH terms: Air
  5. Idris IB, Ghazi HF, Zhie KH, Khairuman KA, Yahya SK, Abd Zaim FA, et al.
    Ann Glob Health, 2016 6 22;82(1):202-8.
    PMID: 27325078 DOI: 10.1016/j.aogh.2016.01.021
    The prevalence of asthma is increasing, especially among children in Malaysia, with environmental factors as one of the main preventable contributors. The aim of this study was to determine the association between environmental air pollutants and the occurrence of asthma among children seen in pediatric clinics in Universiti Kebangsaan Malaysia Medical Center (UKMMC), Kuala Lumpur. An unmatched case control study among children who attended the pediatric clinic was carried out from May to August 2015. A total of 223 children who were diagnosed with asthma (105 cases) and who did not have asthma (118 controls) were included in this study. Their parents or caregivers were interviewed using questionnaires modified from the International Study of Asthma and Allergies in Childhood. Data obtained were analyzed using SPSS software version 20. There was a higher risk of asthma in those who had carpet at home (OR = 2.15 CI [1.25-3.68]), those who lived within 200 m of heavy traffic (OR = 1.72 CI [1.01-2.93]), and those who were exposed to lorry fumes (OR = 2.61. CI [1.38-4.93]). Environmental air pollutants increased the risk of asthma among children in Malaysia. Exposure to congested roads, lorry fumes, and indoor carpet were associated with asthma among children in this study. Parents or caretakers of children with asthma should be given adequate education on the prevention of asthmatic attack among these children.
    Study site: Paediatric clinic, Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM), Kuala Lumpur, Malaysia
    Matched MeSH terms: Air Pollutants/adverse effects*
  6. Ab Manan N, Noor Aizuddin A, Hod R
    Ann Glob Health, 2018 11 05;84(4):670-678.
    PMID: 30779516 DOI: 10.29024/aogh.2376
    IntroductionMany epidemiological studies have demonstrated associations between air pollution levels and human health in terms of hospital admissions. The aim of this paper is to gather evidence concerning air pollution effects on the risk of hospital admission. We hypothesised that increase in: particulate matter (PM), ozone (O3), carbon monoxide (CO), nitrogen dioxide (NO2), and sulphur dioxide (SO2) levels would be associated with the increasing trend of hospital admission.MethodsA systematic review of literature was carried out. Literature search was done in Sage, Ovid Medline, Science Direct, Wiley and ProQuest from 2010 to 2016 using keywords "hospital admission and air pollution". Studies of any relevant design were included if they presented original data, included at least one analysis where hospital admission was the specific outcome, and one or more of the following exposures were investigated: PM, O3, CO, NO2 and SO2.ResultsA total of 175 potential studies were identified by the search. Twenty two studies qualified for the review. Air pollution was noted to have an excessive risk of 3.46 (95%CI, 1.67, 5.27) of total hospital admissions. Cardiovascular admission was noted to have an increased risk of hospitalization for PM2.5 of 1.5 to 2.0; PM10 (1.007 to 2.7); NO2 (1.04 to 1.17) and SO2 (1.007). For respiratory admission, PM2.5 can caused an increased risk of hospitalization by 1.1 to 1.8; PM10 (1.007 to 1.13); NO2 (1.08 to 1.94) and SO2 (1.02). While O3 have minimal effect on COPD and stroke, CO does not influence in the effect of these hospitalization.ConclusionThe exposure to air pollutants confers an increased risk of admission of several disease. Our findings call for greater awareness of environmental protection and the implementation of effective measures to improve the quality of air, which may reduce the risks of adverse effects on the population's health.
    Matched MeSH terms: Air Pollution/adverse effects*
  7. Jamil PASM, Karuppiah K, Rasdi I, How V, Tamrin SBM, Mani KKC, et al.
    Ann Glob Health, 2020 07 28;86(1):84.
    PMID: 32775216 DOI: 10.5334/aogh.2895
    Background: Apart from being exposed to various hazards, there are several other factors that contribute to the deterioration of traffic police health.

    Objectives: A cross-sectional study was carried out to explore the association of occupational, socio-demographic, and lifestyle factors with lung functions in traffic policemen in Kuala Lumpur (KL) and Johor Bahru (JB).

    Methods: A spirometer was used to measure lung function of subjects, whereas a self-administered questionnaire was used to obtain their information on background data, lifestyle, and occupational factors. The statistical test used was Spearman rho's test and chi-square test; then, the factors were further tested using Logistic regressions.

    Findings: 134 male subjects were selected as respondents in this study with 83% response rate. Among all the factors tested, age (FVC: χ = 8.42(3), p = 0.04), (FEV: χ = 8.26(3), p = 0.04), rank (FVC: χ = 8.52(3), p = 0.04), (FEV: χ = 8.05(3), p = 0.04), duration of services (FVC: χ = 11.0(1), p = 0.04), (FEV: χ = 6.53(1), p = 0.01), and average working hours (with the Measured FVC (litre), r = -3.97, p < 0.001; Measured FEV1 (litre), r = -3.70, p < 0.001; Predicted FVC, r = -0.49, p < 0.001; Predicted FEV1, r = -0.47, p < 0.001; and %Ratio FEV1/FV, r = -0.47, p < 0.001) were significantly related to lung function among traffic police.

    Conclusions: Occupational factors play a crucial role, and hence, the authorities should take action in generating flexible working hours and the duration of services accordingly. The data from this study can help by serving as a reference to the top management of traffic police officers to develop occupational safety and health guideline for police officers to comply with the Occupational Safety and Health Act (OSHA, Act 514 1994).

    Matched MeSH terms: Air Pollution
  8. Khamal R, Isa ZM, Sutan R, Noraini NMR, Ghazi HF
    Ann Glob Health, 2019 01 22;85(1).
    PMID: 30741516 DOI: 10.5334/aogh.2425
    INTRODUCTION: Indoor air quality in day care centers (DCCs) is an emerging research topic nowadays. Indoor air pollutants such as particulate matter (PM) and microbes have been linked to respiratory health effects in children, particularly asthma-related symptoms such as night coughs and wheezing due to early exposure to indoor air contaminants.

    OBJECTIVE: The aim of this study was to determine the association between wheezing symptoms among toddlers attending DCCs and indoor particulate matter, PM10, PM2.5, and microbial count level in urban DCCs in the District of Seremban, Malaysia.

    METHODS: Data collection was carried out at 10 DCCs located in the urban area of Seremban. Modified validated questionnaires were distributed to parents to obtain their children's health symptoms. The parameters measured were indoor PM2.5, PM10, carbon monoxide, total bacteria count, total fungus count, temperature, air velocity, and relative humidity using the National Institute for Occupational Safety and Health analytical method.

    RESULTS: All 10 DCCs investigated had at least one indoor air quality parameter exceeding the acceptable level of standard guidelines. The prevalence of toddlers having wheezing symptoms was 18.9%. There was a significant different in mean concentration of PM2.5 and total bacteria count between those with and those without wheezing symptoms (P = 0.02, P = 0.006).

    CONCLUSIONS: Urban DCCs are exposed to many air pollutants that may enter their buildings from various adjacent sources. The particle concentrations and presence of microbes in DCCs might increase the risk of exposed children for respiratory diseases, particularly asthma, in their later life.

    Matched MeSH terms: Air Microbiology/standards; Air Pollution, Indoor/analysis; Air Pollution, Indoor/prevention & control
  9. Vilcins D, Christofferson RC, Yoon JH, Nazli SN, Sly PD, Cormier SA, et al.
    Ann Glob Health, 2024;90(1):9.
    PMID: 38312715 DOI: 10.5334/aogh.4363
    BACKGROUND: The United Nations has declared that humans have a right to clean air. Despite this, many deaths and disability-adjusted life years are attributed to air pollution exposure each year. We face both challenges to air quality and opportunities to improve, but several areas need to be addressed with urgency.

    OBJECTIVE: This paper summarises the recent research presented at the Pacific Basin Consortium for Environment and Health Symposium and focuses on three key areas of air pollution that are important to human health and require more research.

    FINDINGS AND CONCLUSION: Indoor spaces are commonly places of exposure to poor air quality and are difficult to monitor and regulate. Global climate change risks worsening air quality in a bi-directional fashion. The rising use of electric vehicles may offer opportunities to improve air quality, but it also presents new challenges. Government policies and initiatives could lead to improved air and environmental justice. Several populations, such as older people and children, face increased harm from air pollution and should become priority groups for action.

    Matched MeSH terms: Air Pollution, Indoor*
  10. Chia SE, Chia KS, Ong CN
    Ann Acad Med Singap, 1991 Nov;20(6):758-61.
    PMID: 1803964
    Blood lead levels of two ethnic groups (11 Chinese and 25 Malays) of workers in a factory manufacturing lead accumulator battery were studied. The mean adjusted (for environmental lead levels, age, exposure duration and stick-years of smoking by analysis of covariance) blood lead level of the Malays was 34.8 micrograms/dl as compared to 22.4 micrograms/dl for the Chinese. This difference was significant (p less than 0.02). Oral ingestion of lead, through eating of food with hands contaminated by lead compound, among the Malay workers was suggested as a possible cause for the difference in the mean blood lead levels. Preventive measures and recommendations to overcome the problem among this particular group of workers were discussed.
    Matched MeSH terms: Air Pollutants, Occupational/analysis
  11. Wong YP, Saw HY, Janaun J, Krishnaiah K, Prabhakar A
    Appl Biochem Biotechnol, 2011 May;164(2):170-82.
    PMID: 21080102 DOI: 10.1007/s12010-010-9124-8
    Solid-state fermentation (SSF) was employed to enhance the nutritive values of palm kernel cake (PKC) for poultry feeding. Aspergillus flavus was isolated from local PKC and utilized to increase the mannose content of PKC via the degradation of β-mannan in PKC; evaluation was done for batch SSF in Erlenmeyer flasks and in a novel laterally aerated moving bed (LAMB) bioreactor. The optimum condition for batch SSF in flasks was 110% initial moisture content, initial pH 6.0, 30 °C, 855 μm particle size, and 120 h of fermentation, yielding 90.91 mg mannose g⁻¹ dry PKC (5.9-fold increase). Batch SSF in the LAMB at the optimum condition yielded 79.61 mg mannose g⁻¹ dry PKC (5.5-fold increase) within just 96 h due to better heat and mass transfer when humidified air flowed radially across the PKC bed. In spite of a compromise of 12% reduction in mannose content when compared with the flasks, the LAMB facilitated good heat and mass transfer, and improved the mannose content of PKC in a shorter fermentation period. These attributes are useful for batch production of fermented PKC feed in an industrial scale.
    Matched MeSH terms: Air
  12. Dahlan ND, Gital YY
    Appl Ergon, 2016 May;54:169-76.
    PMID: 26851476 DOI: 10.1016/j.apergo.2015.12.008
    The study was done to identify affective and sensory responses observed as a result of hysteresis effects in transient thermal conditions consisting of warm-neutral and neutral - warm performed in a quasi-experiment setting. Air-conditioned building interiors in hot-humid areas have resulted in thermal discomfort and health risks for people moving into and out of buildings. Reports have shown that the instantaneous change in air temperature can cause abrupt thermoregulation responses. Thermal sensation vote (TSV) and thermal comfort vote (TCV) assessments as a consequence of moving through spaces with distinct thermal conditions were conducted in an existing single-story office in a hot-humid microclimate, maintained at an air temperature 24 °C (± 0.5), relative humidity 51% (± 7), air velocity 0.5 m/s (± 0.5), and mean radiant temperature (MRT) 26.6 °C (± 1.2). The measured office is connected to a veranda that showed the following semi-outdoor temperatures: air temperature 35 °C (± 2.1), relative humidity 43% (± 7), air velocity 0.4 m/s (± 0.4), and MRT 36.4 °C (± 2.9). Subjective assessments from 36 college-aged participants consisting of thermal sensations, preferences and comfort votes were correlated against a steady state predicted mean vote (PMV) model. Local skin temperatures on the forehead and dorsal left hand were included to observe physiological responses due to thermal transition. TSV for veranda-office transition showed that no significant means difference with TSV office-veranda transition were found. However, TCV collected from warm-neutral (-0.24, ± 1.2) and neutral-warm (-0.72, ± 1.3) conditions revealed statistically significant mean differences (p < 0.05). Sensory and affective responses as a consequence of thermal transition after travel from warm-neutral-warm conditions did not replicate the hysteresis effects of brief, slightly cool, thermal sensations found in previous laboratory experiments. These findings also indicate that PMV is an acceptable alternative to predict thermal sensation immediately after a down-step thermal transition (≤ 1 min exposure duration) for people living in a hot-humid climate country.
    Matched MeSH terms: Air Conditioning/adverse effects*; Air Conditioning/methods; Air Movements
  13. Loo HS, Yeow PH
    Appl Ergon, 2015 Nov;51:383-91.
    PMID: 26154237 DOI: 10.1016/j.apergo.2015.06.007
    The research aims to address the physically loading task and quality and productivity problems in the brazing of coils of air-handler units. Eight operators participated in two intervention studies conducted in a factory in Malaysia to compare the status quo brazing with (1) the use of a new twin-brazing torch that replaced the single-brazing gun and (2) brazing in a sitting position. The outcome measures are related to quality, productivity, monetary costs, body postures and symptoms. After baseline, Interventions I and II were applied for 3 months respectively. The results show a 58.9% quality improvement, 140% productivity increase and 113 times ROI. There was also a reduction in poor work postures e.g. in the raising of the arms and shoulders; bending, twisting and extending of the neck; and bending of left and right wrists, and the back. This research can be replicated in other factories that share similar processes.
    Matched MeSH terms: Air Conditioning
  14. Ismail B, Redzuwan Y, Chua RS, Shafiee W
    Appl Radiat Isot, 2001 Mar;54(3):393-7.
    PMID: 11214872
    The processing of amang (one of a number of tin-tailing products) for its valuable minerals has associated with the radiological and environmental problems. The processing and stockpiling of amang and ilmenite in open-air spaces, subject as it is to environmental influences, gives rise to a potential for affecting residents in adjacent area. A case study was carried out in a residential area neighbouring a typical amang plant to investigate the radiological impact to the residents. The average Effective Dose rates, calculated based on the contributions of Effective Dose rates from inhaled suspended radioactive dust, radon-thoron and their progeny, and external gamma radiation, were determined for selected houses. Results show that the occupants of those houses received Effective Dose rate, which cannot be differentiated from background. The major contributor to the average Effective Dose rate came from external radiation sources. Inhaled radon and its progeny was the second major contributor.
    Matched MeSH terms: Air Pollutants, Radioactive/adverse effects*; Air Pollutants, Radioactive/analysis; Air Pollution, Indoor/adverse effects; Air Pollution, Indoor/analysis
  15. Hashim SA, Samsudin FN, Wong CS, Abu Bakar K, Yap SL, Mohd Zin MF
    Arch Biochem Biophys, 2016 09 01;605:34-40.
    PMID: 27056469 DOI: 10.1016/j.abb.2016.03.032
    A modular typed dielectric barrier discharge (DBD) device is designed and tested for air and water remediation. The module is made of a number of DBD tubes that can be arranged in series or parallel. Each of the DBD tubes comprises inner electrode enclosed with dielectric barrier and arranged as such to provide a gap for the passage of gases. Non-thermal plasma generated in the gap effectively creates gaseous chemical reactions. Its efficacy in the remediation of gas stream containing high NOx, similar to diesel emission and wastewater containing latex, are presented. A six tubes DBD module has successfully removed more than 80% of nitric oxide from the gas stream. In another arrangement, oxygen was fed into a two tubes DBD to generate ozone for treatment of wastewater. Samples of wastewater were collected from a treatment pond of a rubber vulcanization pilot plant. The water pollution load was evaluated by the chemical oxygen demand (COD) and biological oxygen demand (BOD5) values. Preliminary results showed some improvement (about 13%) on the COD after treatment and at the same time had increased the BOD5 by 42%. This results in higher BOD5/COD ratio after ozonation which indicate better biodegradability of the wastewater.
    Matched MeSH terms: Air*
  16. Razak HA, Wahid NBA, Latif MT
    Arch Environ Contam Toxicol, 2019 Nov;77(4):587-593.
    PMID: 31359072 DOI: 10.1007/s00244-019-00656-3
    Anionic surfactants are one of the pollutants derived from particulate matter (PM) and adversely affect the health of living organisms. In this study, the compositions of surfactants extracted from PM and vehicle soot collected in an urban area were investigated. A high-volume air sampler was used to collect PM sample at urban area based on coarse (> 1.5 µm) and fine (
    Matched MeSH terms: Air Pollutants/analysis*
  17. Eshkoor SA, Ismail P, Rahman SA, Moin S
    Arh Hig Rada Toksikol, 2011 Dec;62(4):291-8.
    PMID: 22202462 DOI: 10.2478/10004-1254-62-2011-2088
    The aim of our study was to see the effects of GSTP1 polymorphism on biomarkers of ageing, including micronuclei (MN), comet tail length, and relative telomere length in automobile repair workers, who are exposed to a broad spectrum of potential mutagens. The analysis was performed on buccal cells collected from occupationally exposed and non-exposed (control) subjects. Samples were analysed using cytogenetic and molecular methods, including restriction fragment length polymorphism (RFLP), MN test, comet assay, and real-time PCR. The results confirmed the DNA damaging effects of substances used in the mechanical workshops, but did not confirm the influence of GSTP1 gene polymorphism on DNA damage. However, further studies on both occupationally exposed and control populations are needed to understand the relationship between GSTP1 polymorphism and genome damage.
    Matched MeSH terms: Air Pollutants, Occupational/adverse effects*
  18. Alnawaiseh NA, Hashim JH, Isa ZM
    Asia Pac J Public Health, 2015 Mar;27(2):NP1742-51.
    PMID: 22899706 DOI: 10.1177/1010539512455046
    The main objective of this cross-sectional comparative study is to observe the relationship between traffic-related air pollutants, particularly particulate matter (PM) of total suspended particulate (TSP) and PM of size 10 µm (PM10), and vehicle traffic in Amman, Jordan. Two study areas were chosen randomly as a high-polluted area (HPA) and low-polluted area (LPA). The findings indicate that TSP and PM10 were still significantly correlated with traffic count even after controlling for confounding factors (temperature, relative humidity, and wind speed): TSP, r = 0.726, P < .001; PM10, r = 0.719, P < .001). There was a significant positive relationship between traffic count and PM level: TSP, P < .001; PM10, P < .001. Moreover, there was a significant negative relationship between temperature and PM10 level (P = .018). Traffic volume contributed greatly to high concentrations of TSP and PM10 in areas with high traffic count, in addition to the effect of temperature.
    Matched MeSH terms: Air Pollutants/analysis*; Air Pollution/analysis*
  19. Yong HH, Foong K, Borland R, Omar M, Hamann S, Sirirassamee B, et al.
    Asia Pac J Public Health, 2010 Jan;22(1):98-109.
    PMID: 20032039 DOI: 10.1177/1010539509351303
    This study examined support for and reported compliance with smoke-free policy in air-conditioned restaurants and other similar places among adult smokers in Malaysia and Thailand. Baseline data (early 2005) from the International Tobacco Control Southeast Asia Survey (ITC-SEA), conducted face-to-face in Malaysia and Thailand (n = 4005), were used. Among those attending venues, reported total smoking bans in indoor air-conditioned places such as restaurants, coffee shops, and karaoke lounges were 40% and 57% in Malaysia and Thailand, respectively. Support for a total ban in air-conditioned venues was high and similar for both countries (82% Malaysian and 90% Thai smokers who believed there was a total ban), but self-reported compliance with bans in such venues was significantly higher in Thailand than in Malaysia (95% vs 51%, P < .001). As expected, reporting a ban in air-conditioned venues was associated with a greater support for a ban in such venues in both countries.
    Matched MeSH terms: Air Conditioning
  20. Hassan NA, Hashim Z, Hashim JH
    Asia Pac J Public Health, 2016 Mar;28(2 Suppl):38S-48S.
    PMID: 26141092 DOI: 10.1177/1010539515592951
    This review discusses how climate undergo changes and the effect of climate change on air quality as well as public health. It also covers the inter relationship between climate and air quality. The air quality discussed here are in relation to the 5 criteria pollutants; ozone (O3), carbon dioxide (CO2), nitrogen dioxide (NO2), sulfur dioxide (SO2), and particulate matter (PM). Urban air pollution is the main concern due to higher anthropogenic activities in urban areas. The implications on health are also discussed. Mitigating measures are presented with the final conclusion.
    Matched MeSH terms: Air Pollutants/analysis*; Air Pollution/adverse effects*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links