Displaying all 5 publications

Abstract:
Sort:
  1. Ang SP, Chia JE, Jaiswal V, Hanif M, Vadhera A, Gautam S, et al.
    Int J Surg, 2024 Apr 01;110(4):2421-2429.
    PMID: 38320107 DOI: 10.1097/JS9.0000000000001132
    BACKGROUND: Chronic steroid (CS) therapy was reportedly linked to increased vascular complications following percutaneous coronary intervention. However, its association with vascular complications after transcatheter aortic valve replacement (TAVR) remained uncertain, with conflicting results being reported.

    OBJECTIVE: The authors aimed to compare the rate of vascular complications and outcomes between patients with and without CS use after TAVR.

    METHODS: The authors conducted a comprehensive literature search in PubMed, Embase, and Cochrane databases from their inception until 18th April 2022 for relevant studies. Endpoints were described according to Valve Academic Research Consortium-2 definitions. Effect sizes were pooled using DerSimonian and Laird random-effects model as risk ratio (RR) with 95% CI.

    RESULTS: Five studies with 6136 patients undergoing TAVR were included in the analysis. The included studies were published between 2015 and 2022. The mean ages of patients in both study groups were similar, with the CS group averaging 80 years and the nonsteroid group averaging 82 years. Notably, a higher proportion of patients in the CS group were female (56%) compared to the nonsteroid group (54%). CS use was associated with a significantly higher risk of major vascular complications (12.5 vs. 6.7%, RR 2.32, 95% CI: 1.73-3.11, P <0.001), major bleeding (16.8 vs. 13.1%, RR 1.61, 95% CI: 1.27-2.05, P <0.001), and aortic annulus rupture (2.3 vs. 0.6%, RR 4.66, 95% CI: 1.67-13.01, P <0.001). There was no significant difference in terms of minor vascular complications (RR 1.43, 95% CI: 1.00-2.04, P =0.05), in-hospital mortality (2.3 vs. 1.4%, RR 1.86, 95% CI: 0.74-4.70, P =0.19), and 30-day mortality (2.9 vs. 3.1%, RR 1.14, 95% CI: 0.53-2.46, P =0.74) between both groups.

    CONCLUSION: Our study showed that CS therapy is associated with increased major vascular complications, major bleeding, and annulus rupture following TAVR. Further large multicenter studies or randomized controlled trials are warranted to validate these findings.

    Matched MeSH terms: Aortic Valve Stenosis/surgery
  2. Tay EL, Hayashida K, Chen M, Yin WH, Park DW, Seth A, et al.
    J Card Surg, 2020 Sep;35(9):2142-2146.
    PMID: 32720374 DOI: 10.1111/jocs.14722
    OBJECTIVES: The impact of the COVID-19 pandemic on the treatment of patient with aortic valve stenosis is unknown and there is uncertainty on the optimal strategies in managing these patients.

    METHODS: This study is supported and endorsed by the Asia Pacific Society of Interventional Cardiology. Due to the inability to have face to face discussions during the pandemic, an online survey was performed by inviting key opinion leaders (cardiac surgeon/interventional cardiologist/echocardiologist) in the field of transcatheter aortic valve implantation (TAVI) in Asia to participate. The answers to a series of questions pertaining to the impact of COVID-19 on TAVI were collected and analyzed. These led subsequently to an expert consensus recommendation on the conduct of TAVI during the pandemic.

    RESULTS: The COVID-19 pandemic had resulted in a 25% (10-80) reduction of case volume and 53% of operators required triaging to manage their patients with severe aortic stenosis. The two most important parameters used to triage were symptoms and valve area. Periprocedural changes included the introduction of teleconsultation, preprocedure COVID-19 testing, optimization of protests, and catheterization laboratory set up. In addition, length of stay was reduced from a mean of 4.4 to 4 days.

    CONCLUSION: The COVID-19 pandemic has impacted on the delivery of TAVI services to patients in Asia. This expert recommendation on best practices may be a useful guide to help TAVI teams during this period until a COVID-19 vaccine becomes widely available.

    Matched MeSH terms: Aortic Valve Stenosis/surgery
  3. Chiam PTL, Hayashida K, Watanabe Y, Yin WH, Kao HL, Lee MKY, et al.
    Open Heart, 2021 01;8(1).
    PMID: 33419935 DOI: 10.1136/openhrt-2020-001541
    OBJECTIVES: Transcatheter aortic valve replacement (TAVR) is increasingly performed. Physically small Asians have smaller aortic root and peripheral vessel anatomy. The influence of gender of Asian patients undergoing TAVR is unknown and may affect outcomes. The aim of this study was to assess sex differences in Asian patients undergoing TAVR.

    METHODS: Patients undergoing TAVR from eight countries were enrolled. In this retrospective analysis, we examined differences in characteristics, 30-day clinical outcomes and 1-year survival between female and male Asian patients.

    RESULTS: Eight hundred and seventy-three patients (54.4% women) were included. Women were older, smaller and had less coronary artery and lung disease but tended to have higher logistic EuroSCOREs. Smaller prostheses were used more often in women. Major vascular complications occurred more frequently in women (5.5% vs 1.8%, p<0.01); however, 30-day stroke and mortality (women vs men: 1.5% vs 1.6%, p=0.95% and 4.3% vs 3.4%, p=0.48) were similar. Functional status improvement was significant and comparable between the sexes. Conduction disturbance and permanent pacemaker requirements (11.2% vs 9.0%, p=0.52) were also similar as was 1-year survival (women vs men: 85.6% vs 88.2%, p=0.25). The only predictors of 30-day mortality were major vascular injury in women and age in men.

    CONCLUSIONS: Asian women had significantly smaller stature and anatomy with some differences in clinical profiles. Despite more frequent major vascular complications, women had similar 30-day stroke or mortality rates. Functional status improvement was significant and comparable between the sexes. Conduction disturbance and permanent pacemaker requirements were similar as was 1-year survival.

    Matched MeSH terms: Aortic Valve Stenosis/surgery*
  4. Ling PK
    Singapore Med J, 2009 Oct;50(10):e350-2.
    PMID: 19907873
    We report a pulmonary artery (PA) aneurysm associated with severe aortic stenosis and an aortic root dilatation occurring in a 59-year-old woman who presented with dyspnoea and chest pain. PA aneurysms are rare, and there are no definitive guidelines on its management. There are contentious opinions on whether such aneurysms should be managed conservatively or surgically. Our patient had associated aortic stenosis and underwent a successful aortic valve replacement and PA aneurysm repair. This case illustrates that concomitant PA repair with other cardiothoracic surgery can be performed safely, even in patients with moderate surgical risks. We also discuss the natural history, prognosis and management of PA aneurysms.
    Matched MeSH terms: Aortic Valve Stenosis/surgery
  5. Basri AA, Zuber M, Basri EI, Zakaria MS, Aziz AFA, Tamagawa M, et al.
    Comput Math Methods Med, 2020;2020:9163085.
    PMID: 32454886 DOI: 10.1155/2020/9163085
    This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA.
    Matched MeSH terms: Aortic Valve Stenosis/surgery*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links