Displaying all 3 publications

Abstract:
Sort:
  1. Low KS, Lee CK, Lee TS
    Environ Technol, 2003 Feb;24(2):197-204.
    PMID: 12675017
    Spent bleaching earth, an industrial waste produced after the bleaching of crude palm oil, was investigated for its potential in removing Cr(VI) from aqueous solution. The earth was treated with different amounts of sulfuric acid and under different activation temperatures. Results show that the optimum treatment process involved 10% sulfuric acid at 350 degrees C. The effects of contact time, pH, initial concentration, sorbent dosage, temperature, sorption isotherms and the presence of other anions on its sorption capacity were studied. Isotherm data could be fitted into a modified Langmuir isotherm model implying monolayer coverage of Cr(VI) on acid activated spent bleaching earth. The maximum sorption capacity derived from the Langmuir isotherm was 21.2 mg g(-1). This value was compared with those of some other low cost sorbents. Studies of anion effect on the uptake of Cr(VI) on acid activated spent bleaching earth provided the following order of suppression: EDTA >PO4(3-)>SO4(2-)>NO3(-)>Cl(-).
    Matched MeSH terms: Carcinogens, Environmental/chemistry*
  2. Tang PL, Lee CK, Low KS, Zainal Z
    Environ Technol, 2003 Oct;24(10):1243-51.
    PMID: 14669804
    The sorption characteristics of Cr(VI) and Cu(II) by ethylenediamine modified rice hull from single and binary metal ion solutions were evaluated under various experimental conditions. Optimal Cr(VI) and Cu(II) removal from single metal ion solutions occurred at pH 2.0 and 5.5, respectively. Simultaneous removal of Cr(VI) and Cu(II) occurred at pH greater than 3.0. The sorption kinetics of Cr(VI) and Cu(II) from single and binary metal ion solutions were studied with reference to metal concentration, agitation rate and particle size. Sorption of Cr(VI) was more rapid than Cu(II). The kinetics of metal ion sorption fitted a pseudo-second order expression. The variation in the initial uptake rates was very small at an agitation rate beyond 150 rpm and sorption was generally independent of particle size. Equilibrium sorption data could be fitted into the Langmuir isotherm equation. Maximum sorption capacities of ethylenediamine modified rice hull for Cr(VI) at pH 2 and Cu(II) at pH 4 in single metal solutions were 0.45 and 0.06 mmol g(-1), respectively. This corresponds to an enhancement factor of 2.6 and 3 fold for Cr(VI) and Cu(II), respectively, compared to natural rice hull. A synergistic effect was observed for sorption of these ions in binary metal solutions.
    Matched MeSH terms: Carcinogens, Environmental/chemistry*
  3. Yibadatihan S, Jinap S, Mahyudin NA
    PMID: 25396715 DOI: 10.1080/19440049.2014.978396
    Palm kernel cake (PKC) is a useful source of protein and energy for livestock. Recently, it has been used as an ingredient in poultry feed. Mycotoxin contamination of PKC due to inappropriate handling during production and storage has increased public concern about economic losses and health risks for poultry and humans. This concern has accentuated the need for the evaluation of mycotoxins in PKC. Furthermore, a method for quantifying mycotoxins in PKC has so far not been established. The aims of this study were therefore (1) to develop a method for the simultaneous determination of mycotoxins in PKC and (2) to validate and verify the method. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using an electrospray ionisation interface (ESI) in both positive- and negative-ion modes was developed for the simultaneous determination of aflatoxins (AFB₁, AFB₂, AFG₁ and AFG₂), ochratoxin A (OTA), zearalenone (ZEA), deoxynivalenol (DON), fumonisins (FB₁ and FB₂), T-2 and HT-2 toxin in PKC. An optimum method using a 0.2 ml min⁻¹ flow rate, 0.2% formic acid in aqueous phase, 10% organic phase at the beginning and 90% organic phase at the end of the gradient was achieved. The extraction of mycotoxins was performed using a solvent mixture of acetonitrile-water-formic acid (79:20:1, v/v) without further clean-up. The mean recoveries of mycotoxins in spiked PKC samples ranged from 81% to 112%. Limits of detection (LODs) and limits of quantification (LOQs) for mycotoxin standards and PKC samples ranged from 0.02 to 17.5 μg kg⁻¹ and from 0.06 to 58.0 μg kg⁻¹, respectively. Finally, the newly developed method was successfully applied to PKC samples. The results illustrated the fact that the method is efficient and accurate for the simultaneous multi-mycotoxin determination in PKC, which can be ideal for routine analysis.
    Matched MeSH terms: Carcinogens, Environmental/chemistry
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links