Displaying all 2 publications

Abstract:
Sort:
  1. Qureshi A, Ismail S, Azmi A, Murugan P, Husin M
    Med J Malaysia, 2000 Jun;55(2):246-8.
    PMID: 19839154
    A prospective analysis of 500 consecutive patients undergoing colonoscopy at the endoscopy unit of Hospital UKM under the care of the surgical unit was analysed. All colonoscopies were supervised by one of two consultant surgeons. The bowel preparation was graded from grade 1 to 4 according to established criteria. All patients had 3 litres of colonic lavage solution as bowel preparation. One hundred and two patients (20.4%) were considered to have poor bowel preparation, while 398 patients (79.6%) had good bowel preparation. Statistically significant factors that resulted in poor bowel preparation included age <20 years and >60 years (p<0.0001), and inpatients (p<0.0193). There was no significant difference in respect to sex, ethnic groups and the indication for colonoscopy. We conclude that young adults and the elderly as well as inpatients are more likely to have a poor bowel preparation using the standard regime.
    Matched MeSH terms: Cathartics/therapeutic use
  2. Tee HP, Corte C, Al-Ghamdi H, Prakoso E, Darke J, Chettiar R, et al.
    World J Gastroenterol, 2010 Aug 21;16(31):3905-10.
    PMID: 20712051
    AIM: To study the significance of cap-fitted colonoscopy in improving cecal intubation time and polyp detection rate.

    METHODS: This study was a prospective randomized controlled trial conducted from March 2008 to February 2009 in a tertiary referral hospital at Sydney. The primary end point was cecal intubation time and the secondary endpoint was polyp detection rate. Consecutive cases of total colonoscopy over a 1-year period were recruited. Randomization into either standard colonoscopy (SC) or cap-assisted colonoscopy (CAC) was performed after consent was obtained. For cases randomized to CAC, one of the three sizes of cap was used: D-201-15004 (with a diameter of 15.3 mm), D-201-14304 (14.6 mm) and D-201-12704 (13.0 mm). All of these caps were produced by Olympus Medical Systems, Japan. Independent predictors for faster cecal time and better polyp detection rate were also determined from this study.

    RESULTS: There were 200 cases in each group. There was no significant difference in terms of demographic characteristics between the two groups. CAC, when compared to the SC group, had no significant difference in terms of cecal intubation rate (96.0% vs 97.0%, P = 0.40) and time (9.94 +/- 7.05 min vs 10.34 +/- 6.82 min, P = 0.21), or polyp detection rate (32.8% vs 31.3%, P = 0.75). On the subgroup analysis, there was no significant difference in terms of cecal intubation time by trainees (88.1% vs 84.8%, P = 0.40), ileal intubation rate (82.5% vs 79.0%, P = 0.38) or total colonoscopy time (23.24 +/- 13.95 min vs 22.56 +/- 9.94 min, P = 0.88). On multivariate analysis, the independent determinants of faster cecal time were consultant-performed procedures (P < 0.001), male patients (P < 0.001), non-usage of hyoscine (P < 0.001) and better bowel preparation (P = 0.01). The determinants of better polyp detection rate were older age (P < 0.001), no history of previous abdominal surgery (P = 0.04), patients not having esophagogastroduodenoscopy in the same setting (P = 0.003), trainee-performed procedures (P = 0.01), usage of hyoscine (P = 0.01) and procedures performed for polyp follow-up (P = 0.01). The limitations of the study were that it was a single-center experience, no blinding was possible, and there were a large number of endoscopists.

    CONCLUSION: CAC did not significantly different from SC in term of cecal intubation time and polyp detection rate.

    Matched MeSH terms: Cathartics/therapeutic use
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links