Displaying 1 publication

Abstract:
Sort:
  1. Nik Muhamad NA, Safferi RS, Robertson CE
    Med J Malaysia, 2015 Apr;70(2):63-6.
    PMID: 26162379 MyJurnal
    OBJECTIVE: To determine the correlation between central venous pressure (CVP) measured by conventional central venous access and ultrasonographic measurement of internal jugular vein (IJV) height and inferior vena cava (IVC) diameter.
    METHODS: A prospective, cross-sectional, convenience sampling observational study.
    RESULTS: 25 patients from the Emergency Department (ED) Universiti Kebangsaan Malaysia Medical Centre (UKMMC) were studied between 1st March and 30th April 2013. The median age was 63 years (95% CI 54-67). There was a significant correlation between IJV height and CVP using central venous access (r=0.64 p<0.001). Correlation between IVC diameter in end expiration and CVP was 0.74 (p<0.001). An IJV height measurement >8cm predicted a CVP >8cm H2O (sensitivity 71.4%, specificity of 83.3%).
    CONCLUSION: Measurement of IJV height and IVC diameter by ultrasonography correlates well with invasive CVP and is useful for the assessment of volume status in critically ill patients in the ED.
    Study site: Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur
    Matched MeSH terms: Central Venous Pressure*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links