Displaying all 6 publications

Abstract:
Sort:
  1. Alwi M, Kang LM, Samion H, Latiff HA, Kandavel G, Zambahari R
    Am J Cardiol, 1997 May 15;79(10):1430-2.
    PMID: 9165178 DOI: 10.1016/s0002-9149(97)00160-4
    Two hundred eleven patients with small- to moderate-sized native patent ductus arteriosus underwent closure using Gianturco coils, employing the transvenous multiple catheter approach. Short-term results showed a high rate of complete occlusion and a potential long-term complication of mild left pulmonary artery stenosis in a small number of patients.
    Matched MeSH terms: Ductus Arteriosus, Patent/therapy*
  2. Bilkis AA, Alwi M, Hasri S, Haifa AL, Geetha K, Rehman MA, et al.
    J Am Coll Cardiol, 2001 Jan;37(1):258-61.
    PMID: 11153748 DOI: 10.1016/s0735-1097(00)01094-9
    Objectives: The aim of the study was to assess the safety and efficacy of the Amplatzer ductal occluder (ADO) in transcatheter occlusion of patent ductus arteriosus (PDA).
    Background: Transcatheter closure of small to moderate sized PDAs is an established procedure. The ADO is a self-expandable device with a number of salutary features, notably its retrievability, ease of delivery via small 5F to 7F catheters and a range of sizes suitable even for the larger PDAs.
    Methods: Between November 1997 and August 1999, the ADO was successfully implanted in 205 of 209 patients with PDA. The inclusion criteria for this device occlusion method were patients with clinical and echocardiographic features of moderate to large PDA, weighing > or =3.5 kg as well as asymptomatic adolescents and adults with PDA measuring > or =5.0 mm on two-dimensional (2D) echocardiogram. Occlusion was achieved via the antegrade venous approach. Follow-up evaluations were performed with 2D echocardiogram, color-flow mapping and Doppler measurement of the descending aorta and left pulmonary artery velocity at 24 h and 1, 3, 6 and 12 months after implantation.
    Results: Two hundred and five patients had successful PDA occlusion using this device. The patients were between two months and 50 years (median 1.9) and weighed between 3.4 kg and 63.2 (median 8.4). Infants made up 26% of the total patients. The PDA measured from 1.8 to 12.5 mm (mean 4.9) at the narrowest diameter. Forty-four percent of patients achieved immediate complete occlusion. On color Doppler the closure rates at 24 h and 1 month after implant were 66% and 97%, respectively. At 6 and 12 months all except one patient attained complete occlusion. Device embolization occurred in three patients; in two this was spontaneous, and in the other it was due to catheter manipulation during postimplant hemodynamic measurement. Mild aortic narrowing was seen in an infant.
    Conclusions: Patent ductus arteriosus occlusion using ADO is safe and efficacious. It is particularly useful in symptomatic infants and small children with relatively large PDA. Embolization can be minimized by selection of appropriate sized devices, and caution should be exercised in infants <5 kg.
    Matched MeSH terms: Ductus Arteriosus, Patent/therapy*
  3. Alwi M, Choo KK, Latiff HA, Kandavello G, Samion H, Mulyadi MD
    J Am Coll Cardiol, 2004 Jul 21;44(2):438-45.
    PMID: 15261945 DOI: 10.1016/j.jacc.2004.03.066
    Objectives: This study was designed to assess the safety, efficacy, medium-term outcome, and complications of patent ductus arteriosus (PDA) stenting in duct-dependent pulmonary circulation.
    Background: Patent ductus arteriosus stenting has been proposed as an alternative to surgical shunt on account of postoperative morbidity and complications of surgical shunting.
    Methods: Between April 2000 and February 2003, 69 patients with duct-dependent pulmonary circulation underwent cardiac catheterization with the intent of PDA stenting as first palliative procedure. Patients with critical pulmonary stenosis and pulmonary atresia with intact ventricular septum post-radiofrequency valvotomy who had PDA stenting were excluded. Thirteen more patients were excluded because of branch pulmonary artery (PA) stenosis. The follow-up was by clinical examination, echocardiography, and repeat cardiac catheterization at six to nine months following the procedure.
    Results: Patent ductus arteriosus stenting was successful in 51 patients (91.1%) and failed in 5 patients (8.9%). The mean narrowest PDA diameter was 1.9 +/- 0.6 mm. The mean procedure and fluoroscopy time were 95.7 min and 29.4 min, respectively. In one patient the stent dislodged and migrated to the left femoral artery and another patient developed transient intravascular hemolysis. There was no procedure-related mortality. Three patients (5.9%) died one day to two months after the procedure. At follow-up (3.2 months to 2.4 years), 8 patients developed significant stent stenosis requiring reintervention. Seven patients developed worsening of preexisting branch PA stenosis. The freedom from reintervention was 89% and 55% at 6 months and 1 year, respectively.
    Conclusions: Patent ductus arteriosus stenting is an attractive alternative to surgical shunt in a majority of patients with duct-dependent circulation. An absolute contraindication to this technique is the presence of branch pulmonary stenosis.
    Matched MeSH terms: Ductus Arteriosus, Patent/therapy*
  4. Alwi M
    Future Cardiol, 2012 Mar;8(2):237-50.
    PMID: 22413983 DOI: 10.2217/fca.12.4
    Maintaining ductal patency in duct-dependent congenital heart lesions by implantation of coronary stents is an alternative to systemic pulmonary shunt in selected cases and lesions with suitable anatomy. This article focuses on the procedure as the initial palliation in duct-dependent pulmonary circulation, its associated pitfalls and complications. A good understanding of the diverse duct morphology is paramount prior to stenting of the ductus. Long tortuous duct, insufficiently constricted ductus at the pulmonary end and ductus with associated branch pulmonary artery stenosis at the site of insertion are not suitable for stenting. Durability of palliation is generally inferior to a surgical shunt and this may dictate earlier definitive surgical repair. Acceleration of branch pulmonary artery stenosis in certain ductal morphology limits its general applicability. Bioabsorbable and biodegradable stents may offer some solution to this problem.
    Matched MeSH terms: Ductus Arteriosus, Patent/therapy*
  5. Zanjani KS, Wong AR, Sadiq M, Weber HS, Cutler NG
    Congenit Heart Dis, 2010 Sep-Oct;5(5):439-43.
    PMID: 21087429 DOI: 10.1111/j.1747-0803.2010.00448.x
    Objectives: There is little evidence in the medical literature about safety of PDA device closure and its effects on aortic root diameter in Marfan patients. We reported on nine Marfan patients whose ducts were occluded by coil or Amplatzer Duct Occluder.
    Patients and interventions: Two patients had aneurismal type E ducts which were closed by a single coil, respectively. The others had conical ducts for which even Amplatzer occluder, stiff, or double coils were used.
    Results: No untoward consequence was found during a median follow up period of 18.5 months (range 3 months to 6.33 years). Two patients had small residual shunts. The observed change in the mean ratio of aortic root diameter to its estimated value was statistically insignificant in seven patients who had complete data on their aortic root diameter before PDA closure and during the follow up.
    Conclusions: We concluded that PDA device closure in Marfan patients is safe. Risk of residual shunt is higher even after closure of small ducts.
    Matched MeSH terms: Ductus Arteriosus, Patent/therapy*
  6. Alwi M, Choo KK, Radzi NA, Samion H, Pau KK, Hew CC
    J. Thorac. Cardiovasc. Surg., 2011 Jun;141(6):1355-61.
    PMID: 21227471 DOI: 10.1016/j.jtcvs.2010.08.085
    Objectives: Our objective was to determine the feasibility and early to medium-term outcome of stenting the patent ductus arteriosus at the time of radiofrequency valvotomy in the subgroup of patients with pulmonary atresia with intact ventricular septum and intermediate right ventricle.
    Background: Stenting of the patent ductus arteriosus and radiofrequency valvotomy have been proposed as the initial intervention for patients with intermediate right ventricle inasmuch as the sustainability for biventricular circulation or 1½-ventricle repair is unclear in the early period.
    Methods: Between January 2001 and April 2009, of 143 patients with pulmonary atresia and intact ventricular septum, 37 who had bipartite right ventricle underwent radiofrequency valvotomy and stenting of the patent ductus arteriosus as the initial procedure. The mean tricuspid valve z-score was -3.8 ± 2.2 and the mean tricuspid valve/mitral valve ratio was 0.62 ± 0.16.
    Results: Median age was 10 days (3-65 days) and median weight 3.1 kg (2.4-4.9 kg). There was no procedural mortality. Acute stent thrombosis developed in 1 patient and necessitated emergency systemic-pulmonary shunt. There were 2 early in-hospital deaths owing to low cardiac output syndrome. One late death occurred owing to right ventricular failure after the operation. Survival after the initial procedure was 94% at 6 months and 91% at 5 years. At a median follow-up of 4 years (6 months to 8 years), 17 (48%) attained biventricular circulation with or without other interventions and 9 (26%) achieved 1½-ventricle repair. The freedom from reintervention was 80%, 68%, 58%, and 40% at 1, 2, 3, and 4 years, respectively.
    Conclusions: Concomitant stenting of the patent ductus arteriosus at the time of radiofrequency valvotomy in patients with pulmonary atresia with intact ventricular septum and intermediate right ventricle is feasible and safe with encouraging medium-term outcome.
    Matched MeSH terms: Ductus Arteriosus, Patent/therapy*