Displaying all 4 publications

Abstract:
Sort:
  1. Latif BM, Jakubek EB
    Trop Biomed, 2008 Dec;25(3):225-31.
    PMID: 19287361
    Flourescent antibody test (FAT) was applied to determine the cross-reactivities of monoclonal (mAb), polyclonal (pAb) antibodies to Neospora, Toxoplasma and Cryptosporidium and antisera from cattle naturally infected with Neospora canium against antigens from a number of sources. Both mAb and pAb to Neospora reacted strongly (FAT titre up to 2560) with the homologous antigens and demonstrated weak titre (80) or no reaction with both Toxoplasma and Cryptosporidium antigens. Also mAb and pAb to Toxoplasma gondii reacted at titres of 80 - 640 with homologous antigens and at titres of 10-40 with N. caninum. No cross-reactions with either mAb or pAb antibodies to N. caninum and T. gondii were observed with Cryptosporidium parvum. The same results were observed with C. parvum mAb when tested with both N. caninum and T. gondii antigens. Sera from cattle naturally infected with N. caninum had titres ranging from 80- 640 with N. caninum antigens, and 10- 40 with T. gondii and C. parvum antigens. At low dilutions, the complete surfaces of Neospora and Toxoplasma parasites were fluorescent, while in higher dilutions only dotted fluorescence appeared on the apical complex. These results indicated the presence of cross-reactivity between Neospora and Toxoplasma but not with Cryptosporidium. Accordingly the recommended cut-off antibody titre for diagnosis of neosporosis is 80.
    Matched MeSH terms: Fluorescent Antibody Technique/methods*
  2. Al-Mekhlafi MA, Fatmah MS, Anisah N, Azlin M, Al-Mekhlafi HM, Norhayati M
    PMID: 21323160
    Abstract. The species identification of Enterocytozoon bieneusi and Encephalitozoon intestinalis is only possible using transmission electron microscopy (TEM), mo lecular techniques and immunofluorescence antibody assays (IFA). In this study, 50 positive and 50 negative fecal specimens for microsporidial spores using the Weber modified trichrome (WMT) staining technique were examined using IFA-MAbs. Of the 100 specimens examined, the microsporidial spores identified by IFA-MAbs were Enterocytozoon Bieneusi 42 (75%) Encephalitozoon intestinalis 7 (12.5%) and mixed infections 7 (12.5%). The sensitivity and specificity of IFA-MAbs in detecting microsporidial spores were 98% and 86%, respectively. The agreement between the WMT staining technique and IFA-MAbs was statistically significant by Kappa statistics (K = 0.840; p < 0.001). E. bieneusi was the commonest Microsporidia species isolated from the studied population; the presence of microsporidial spores detected by IFA-MAbs should be confirmed by other methods.
    Matched MeSH terms: Fluorescent Antibody Technique/methods
  3. Huxsoll DL, Shirai A, Robinson DM, Yap LF, Lim BL
    PMID: 411180
    Dog sera, collected from different communities throughout Selangor, Peninsular Malaysia, were investigated for the presence of antibodies to R. tsutsugamushi and R. typhi. Scrub typhus antibodies were present in animals from the rural areas only, whereas murine typhus antibodies were observed in equal numbers of dogs from both rural and metropolitan areas. Greater percentage of dogs from suburban areas had demonstrable antibody titers to murine typhus than from the urban area.
    Matched MeSH terms: Fluorescent Antibody Technique/methods
  4. Darwish NT, Sekaran SD, Alias Y, Khor SM
    J Pharm Biomed Anal, 2018 Feb 05;149:591-602.
    PMID: 29197806 DOI: 10.1016/j.jpba.2017.11.064
    The sharp increase in incidence of dengue infection has necessitated the development of methods for the rapid diagnosis of this deadly disease. Here we report the design and development of a reliable, sensitive, and specific optical immunosensor for the detection of the dengue nonstructural protein 1 (NS1) biomarker in clinical samples obtained during early stages of infection. The present optical NS1 immunosensor comprises a biosensing surface consisting of specific monoclonal NS1 antibody for immunofluorescence-based NS1 antigen determination using fluorescein isothiocyanate (FITC) conjugated to IgG antibody. The linear range of the optical immunosensor was from 15-500ngmL-1, with coefficient of determination (R2) of 0.92, high reproducibility (the relative standard deviation obtained was 2%), good stability for 21days at 4°C, and low detection limit (LOD) at 15ngmL-1. Furthermore, the optical immunosensor was capable of detecting NS1 analytes in plasma specimens from patients infected with the dengue virus, with low cross-reaction with plasma specimens containing the Japanese encephalitis virus (JEV) and Zika virus. No studies have been performed on the reproducibility and cross-reactivity regarding NS1 specificity, which is thus a limitation for optical NS1 immunosensors. In contrast, the present study addressed these limitations carefully where these two important experiments were conducted to showcase the robustness of our newly developed optical-based fluorescence immunosensor, which can be practically used for direct NS1 determination in any untreated clinical sample.
    Matched MeSH terms: Fluorescent Antibody Technique/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links