Displaying all 3 publications

Abstract:
Sort:
  1. Ng ES, Ting JR, Foo SL, Akram SA, Fadzlina AA, Alywiah JS, et al.
    Med J Malaysia, 2006 Dec;61 Suppl B:23-6.
    PMID: 17600989
    The conventional upper arm tourniquet used for hand and wrist operations may cause significant discomfort to patient when the procedure is performed under local anaesthesia. Forearm tourniquet causes less muscle ischeamia and pain. The discomfort experienced while using a forearm and upper arm tourniquet was assessed in 96 healthy subjects. Tourniquet placed on both sides was inflated sequentially to 250mmhg for five minutes on different hand. The discomfort level was assessed using a small visual analogue scale and complications were recorded. In the upper arm tourniquet, 24.9% had mild, 60.5% had moderate and 14.6% had severe pain whereas with forearm tourniquet, 99% had mild pain and only 1% had moderate pain. Seventy-nine percent of the subjects tested with forearm tourniquet had no discomfort at all. The average discomfort level for upper arm and forearm tourniquet was 4.72 and 0.39 respectively, which is statistically significant. Complications that were observed only in upper arm tourniquet included prolonged tingling, burning sensation and discomfort and stiffness of the upper limb. We concluded that forearm tourniquet was safe and well tolerated and should be used more often when indicated.
    Matched MeSH terms: Forearm/surgery*
  2. Abdelzaher E, Elwany A, Amr SA
    Malays J Pathol, 2018 Dec;40(3):355-358.
    PMID: 30580369
    Malignant peripheral nerve sheath tumour (MPNST) with perineurial differentiation is a rare variant of MPNST. The pathological features and clinical significance of this variant remain to be characterised. We reported the clinicoradiological and pathological features of a case of recurrent right arm mass related to the ulnar nerve in a 42-year-old female patient. On pathological examination, the tumour showed dual features of conventional and perineurial MPNST which was proven by positive immunostaining for S-100 and EMA. The pathological diagnosis was MPNST with perineurial differentiation. In addition, a peculiar and rare finding of intracytoplasmic eosinophilic hyaline globules (thanatosomes) within tumour cells is reported. We document a rare tumour with hybrid features between conventional and perineurial MPNSTs. Further studies are needed to establish its biological behaviour.
    Matched MeSH terms: Forearm/surgery
  3. Yammine K, Erić M
    Surg Radiol Anat, 2020 Mar;42(3):259-267.
    PMID: 31741040 DOI: 10.1007/s00276-019-02381-x
    INTRODUCTION: The tendon of the palmaris longus is commonly used as a tendon graft in many reconstructive surgeries. Easy to access and at proximity to the hand, the palmaris longus tendon is considered as the optimal tendon source for hand reconstructive surgery. However, and besides its inconsistency, the size of the palmaris longus tendon is reported to show variability. The aim of this study is to look for the surgical adequacy of the palmaris longus tendon by conducting a quantitative synthesis on its length and width in human populations and its correlation with the forearm length.

    METHODS: Twenty-four studies met the inclusion criteria including 1761 cadaveric limbs.

    RESULTS: The results were as following: (a) the mean palmaris longus tendon length was of 13.9 ± 2.6 cm, (b) the mean ratio palmaris longus tendon length/forearm length was of 0.545 ± 0.06, (c) the weighted correlation value was of 0.686, and (d) the mean palmaris longus tendon width was of 4.0 ± 1.7 mm. Only five studies reported a palmaris longus tendon length of more than 15 cm. The palmaris longus tendon length was shown to vary between ancestries; the Japanese had the shortest while Malaysian the longest palmaris longus tendons. All studies but one reported a palmaris longus tendon mean width of more than 3 mm where the minimal mean palmaris longus tendon width was of 2.5 mm.

    CONCLUSION: While the requested length depends on the recipient site and/or type of reconstructive surgery, the palmaris longus tendon often met the required diameter for grafting. Our review demonstrated that while palmaris longus length varies between ancestries, its width is often adequate for grafting. In addition, the forearm length could be a good predictor of palmaris longus tendon length; such correlation could assist surgeons when planning to use palmaris longus tendon as a graft source.

    Matched MeSH terms: Forearm/surgery