Displaying all 9 publications

Abstract:
Sort:
  1. Izham IN, Zamrin DM, Joanna OS, Ramzisham AR, Hairolfaizi H, Ishamuddin IM, et al.
    Clin Ter, 2011;162(6):521-5.
    PMID: 22262321
    The effect of the duration of ischaemic myocardial time to left ventricular ejection fraction (LVEF) after valve replacement surgery has been attributed. This study aims to look at the correlation between myocardial ischaemic time and changes LVEF post valve replacement surgery up to 6 months period.
    Matched MeSH terms: Heart Valve Prosthesis Implantation*
  2. Le Ho Y, Ahmad Zaidi NA, Salleh A, Abdul Kareem BA
    J Cardiothorac Surg, 2021 Apr 17;16(1):92.
    PMID: 33865405 DOI: 10.1186/s13019-021-01458-2
    BACKGROUND: Antiphospholipid syndrome is an antibody mediated pro-thrombotic state leading to various arterial and venous thromboses. The syndrome can be either primary or secondary to other autoimmune diseases, commonly systemic lupus erythematosus. Cardiac involvement, in particular valvular disease is common in patients with antiphospholipid syndrome, occurring in about a third of these patients. Valvular diseases associated with antiphospholipid syndrome often occur as valve thickening and non-bacterial vegetation or Libman-Sacks endocarditis. Deposits of antiphospholipid immunoglobulin and complement components are commonly observed in the affected valves, suggesting an inflammatory process resulting in valvular vegetation and thickening. Libman-Sacks endocarditis has a high propensity towards mitral valve, although haemodynamically significant valvular dysfunction is rare.

    CASE PRESENTATION: We present a successful aortic valve replacement with cardiopulmonary bypass in a 48 years old lady with antiphospholipid syndrome, who has severe aortic regurgitation as a result of Libman-sacks endocarditis. Antiphospholipid antibodies were positive and the clinical data showed both negative cultures and infective parameters. Surgically resected vegetations revealed sterile fibrinous and verrucous vegetations on aortic valve. Valve replacement and the course of cardiopulmonary bypass was uneventful, and the patient was discharged well.

    CONCLUSIONS: Classically Libman-Sacks endocarditis is often and more commonly associated with autoimmune diseases such as systemic lupus erythematosus, although it can occur in both primary and secondary antiphospholipid syndrome. It is not a common entity, and it is a frequent underestimated disease as most clinicians do not routinely screen for valvular lesion in patients with antiphospholipid syndrome unless they are symptomatic. However, due to its high prevalence of cardiac involvement, clinicians should have a high index of suspicion in the attempt to minimize cardiovascular and haemodynamic complications. Valve surgery in patients with antiphospholipid syndrome carries considerable early and late morbidity and mortality, usually caused by thromboembolic and bleeding events. The perioperative anticoagulation management and haemostatic aspect of antiphospholipid syndrome present an exceptional challenges to clinicians, surgeons, anaesthetists and laboratory personnel.

    Matched MeSH terms: Heart Valve Prosthesis Implantation*
  3. Yakub MA, Dillon J, Krishna Moorthy PS, Pau KK, Nordin MN
    Eur J Cardiothorac Surg, 2013 Oct;44(4):673-81.
    PMID: 23447474 DOI: 10.1093/ejcts/ezt093
    Contemporary experience with mitral valve (MV) repair in the rheumatic population is limited. We aimed to examine the long-term outcomes of rheumatic MV repair, to identify the predictors of durability and to compare the repair for rheumatic and degenerative MVs.
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/methods*
  4. Abbas SS, Nasif MS, Al-Waked R, Meor Said MA
    Artif Organs, 2020 Feb;44(2):E20-E39.
    PMID: 31378963 DOI: 10.1111/aor.13536
    Platelet activation induced by shear stresses and non-physiological flow field generated by bileaflet mechanical heart valves (BMHVs) leads to thromboembolism, which can cause fatal consequences. One of the causes of platelet activation could be intermittent regurgitation, which arises due to asynchronous movement and rebound of BMHV leaflets during the valve closing phase. In this numerical study, the effect of intermittent regurgitation on the platelet activation potential of BMHVs was quantified by modeling a BMHV in the straight and anatomic aorta at implantation tilt angles 0°, 5°, 10°, and 20°. A fully implicit Arbitrary Lagrangian-Eulerian-based Fluid-Structure Interaction formulation was adopted with blood modeled as a multiphase, non-Newtonian fluid. Results showed that the intermittent regurgitation and consequently the platelet activation level increases with the increasing implantation tilt of BMHV. For the straight aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 20° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 8.5°, 3°, and 0°, respectively. For the anatomic aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 24° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 14°, 10°, and 7°, respectively. For all the implantation orientations of BMHVs, intermittent regurgitation and platelet activation were always higher in the anatomic aorta than in the straight aorta. The study concludes that the pivot axis of BMHV must be implanted parallel to the aortic root's curvature to minimize intermittent regurgitation and platelet activation.
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/instrumentation*
  5. Riahi M, Ang HL, Jones M, Prachasilchai P, Baruteau AE, Promphan W, et al.
    Circ Cardiovasc Interv, 2018 04;11(4):e005923.
    PMID: 29618579 DOI: 10.1161/CIRCINTERVENTIONS.117.005923
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/instrumentation*; Heart Valve Prosthesis Implantation/methods
  6. Krishna Moorthy PS, Sivalingam S, Dillon J, Kong PK, Yakub MA
    Interact Cardiovasc Thorac Surg, 2019 02 01;28(2):191-198.
    PMID: 30085022 DOI: 10.1093/icvts/ivy234
    OBJECTIVES: Contemporary experience in mitral valve (MV) repair for children with rheumatic heart disease (RHD) is limited, despite the potential advantages of repair over replacement. We reviewed our long-term outcomes of rheumatic MV repair and compared them with the outcomes of MV replacement in children with RHD.

    METHODS: This study is a review of 419 children (≤18 years) with RHD who underwent primary isolated MV surgery between 1992 and 2015, which comprised MV repair (336 patients; 80.2%) and MV replacement (83 patients; 19.8%). The replacement group included mechanical MV replacements (MMVRs) (n = 69 patients; 16.5%) and bioprosthetic MV replacements (n = 14 patients; 3.3%). The mean age with standard deviation at the time of operation was 12.5 ± 3.5 (2-18) years. Mitral regurgitation (MR) was predominant in 390 (93.1%) patients, and 341 (81.4%) patients showed ≥3+ MR. The modified Carpentier reconstructive techniques were used for MV repair.

    RESULTS: Overall early mortality was 1.7% (7 patients). The mean follow-up was 5.6 years (range 0-22.3 years; 94.7% complete). Survival of patients who underwent repair was 93.9% both at 10 and 20 years, which was superior than that of replacement (P 

    Matched MeSH terms: Heart Valve Prosthesis Implantation/methods*
  7. Qureshi AU, Abbaker AE, Sivalingam S, Latiff HA
    PMID: 24668992 DOI: 10.1177/2150135113509819
    Valved bovine jugular vein (Contegra) conduit is considered a suitable choice for pediatric population with congenital heart defect requiring right ventricle to main pulmonary artery connection. Intermediate follow-up studies have shown the propensity of developing distal conduit stenosis and valve thrombosis. We present a rare case of aneurysmal dilatation of the conduit leading to valve failure requiring conduit explantation.
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects*
  8. Gan GG, Phipps ME, Lee MM, Lu LS, Subramaniam RY, Bee PC, et al.
    Ann Hematol, 2011 Jun;90(6):635-41.
    PMID: 21110192 DOI: 10.1007/s00277-010-1119-6
    Within the Asian populations, Indian patients had been reported to require higher warfarin dose compared with the Chinese and Malay patients, and this could not entirely be explained by cytochrome P450 (CYP)2C9 gene variants. Genetic variants of vitamin K epoxide oxidase reductase complex subunit 1 (VKORC1) has been well established as one of key determinants in the different responses of warfarin amongst patients. Adult patients who attended an anticoagulation clinic with stable INR were recruited. VKORC1 and CYP2C9 genotype were sequenced, and clinical characteristics were assessed. A total of 91 Malays, 96 Chinese, and 46 Indian patients were recruited. The mean age was 55 years and 51.5% were males. The mean dose of warfarin for all patients was 3.7 mg, and the mean daily dose of warfarin was significantly higher in Indians compared with the Chinese and Malay patients, 4.9 versus 3.5 and 3.3 mg, respectively (p 
    Matched MeSH terms: Heart Valve Prosthesis Implantation/statistics & numerical data
  9. Haron H, Yusof MR, Maskon O, Ooi J, Rahman MR
    Heart Surg Forum, 2012 Feb;15(1):E59-60.
    PMID: 22360910 DOI: 10.1532/HSF98.20111000
    Papillary fibroelastoma is a rare primary tumor of the heart valves. This lesion can occur on any of the valves or endothelial surface of the heart and has been detected by echocardiography, by cardiac catheterization, during open heart operations for other conditions, and at autopsy. Because of the potential for comorbidities, this tumor should be removed. We present the case of an elderly man with a diagnosis of severe mitral valve regurgitation and moderate tricuspid valve regurgitation who was suspected to have a tricuspid valve vegetation. Mitral valve replacement, tricuspid valve repair, and excision of the lesion were performed successfully. A histologic examination of the vegetation confirmed it to be a papillary fibroelastoma. We present this case to emphasize the rarity of this tumor and the importance of a correct diagnosis to avoid delaying its prompt and definitive management.
    Matched MeSH terms: Heart Valve Prosthesis Implantation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links