METHODS: Seventeen patients undergoing elective cardiac surgery using CPB and isoflurane with BIS monitoring were recruited in a single-centre university hospital. Isoflurane gas was delivered via a calibrated vaporiser at the beginning of anaesthetic induction. Radial arterial blood samples were collected after the initiation of CPB and before aortic cross-clamping, which were analysed for isoflurane by gas chromatography and mass spectrometry. The BIS score and the concentration of exhausted isoflurane from the oxygenator membrane, as measured by an anaesthetic gas analyser, were recorded at the time of blood sampling.
RESULTS: The mean duration of anaesthetic induction to arterial blood sampling was 90 min (95%CI: 80,100). On CPB, the median BIS was 39 (range, 7-43) and the mean oxygenator exhaust isoflurane concentration was 1.24 ± 0.21%. No significant correlation was demonstrated between BIS with arterial isoflurane concentration (r=-0.19, p=0.47) or oxygenator exhaust isoflurane concentration (r=0.07, p=0.80). Mixed-venous blood temperature was moderately correlated to BIS (r=0.50, p=0.04). Oxygenator exhaust isoflurane concentration was moderately, positively correlated with its arterial concentration (r=0.64, p<0.01).
DISCUSSION: In conclusion, in patients undergoing heart surgery with CPB, the findings of this study indicate that, whilst oxygenator exhaust concentrations were significantly associated with arterial concentrations of isoflurane, neither had any association with the BIS scores, whereas body temperature has moderate positive correlation.
METHODS: During isoflurane-supplemented remifentanil-based anesthesia for patients undergoing cardiac surgery with preoperative LV ejection fraction greater than 50% (n = 20), we analyzed the changes of S' at each isoflurane dose increment (1.0, 1.5, and 2.0 minimum alveolar concentration [MAC]: T1, T2, and T3, respectively) with a fixed remifentanil dosage (1.0 μg/min/kg) by using transesophageal echocardiography.
RESULTS: Mean S' values (95% confidence interval [CI]) at T1, T2, and T3 were 10.5 (8.8-12.2), 9.5 (8.3-10.8), and 8.4 (7.3-9.5) cm/s, respectively (P < 0.001 in multivariate analysis of variance test). Their mean differences at T1 vs. T2, T2 vs. T3, and T1 vs. T3 were -1.0 (-1.6, -0.3), -1.1 (-1.7, -0.6), and -2.1 (-3.1, -1.1) cm/s, respectively. Phenylephrine infusion rates were significantly increased (0.26, 0.22, and 0.47 μg/kg/min at T1, T2, and T3, respectively, P < 0.001).
CONCLUSION: Isoflurane increments (1.0-2.0 MAC) dose-dependently reduced LV systolic long-axis performance during cardiac surgeries with a preserved preoperative systolic function.