Abstract:
Sort:
  1. Chan SW, Liew LH, Wong GR, Kallarakkal TG, Abraham MT, Ramanathan A, et al.
    Int. J. Surg. Pathol., 2016 Aug;24(5):401-9.
    PMID: 27006298 DOI: 10.1177/1066896916639372
    BACKGROUND: Turnaround time (TAT) is the benchmark to assess the performance of a laboratory, pathologists, and pathology services, but there are few articles on TAT of surgical pathology, particularly in relation to oral or head and neck specimens. This study investigates the TAT for oral histopathology reporting in an academic institution's training laboratory and offers recommendations to achieve better overall quality of diagnostic services.

    METHODS: This study examined data obtained from biopsy request forms for specimens received from the Oro-Maxillofacial Surgery Department of Hospital Tengku Ampuan Rahimah Klang in the Oral Pathology Diagnostic Laboratory of the Faculty of Dentistry, University of Malaya, over a period of 3 years between January 2012 and October 2014.

    RESULTS: TAT for surgical and decalcified specimens were increased significantly compared to biopsies. Additional special handling did not influence TAT, but increased specimen volume resulted in greater TAT. Slide interpretation was the most time-consuming stage during histopathology reporting. Overall, mean TAT was acceptable for most specimens, but the TAT goals were less than satisfactory.

    CONCLUSION: A TAT goal appropriate for this laboratory may hence be established based on this study. Collective efforts to improve the TAT for various specimens are essential for better laboratory performance in the future.
    Matched MeSH terms: Pathology, Surgical/standards*
  2. Khoo JJ
    Med J Malaysia, 2004 Mar;59(1):50-5.
    PMID: 15535336 MyJurnal
    A 4-year-review was carried out on intraoperative frozen section consultations in Sultanah Aminah Hospital, Johor Bahru. Two hundred and fifteen specimens were received from 79 patients in the period between January 1999 and December 2002. An average of 2.72 specimens per patient was received. The overall diagnostic accuracy was high, 97.56%. The diagnoses were deferred in 4.65% of the specimens. False positive diagnoses were made in 3 specimens (1.46%) and false negative diagnoses in 2 specimens (0.98%). This gave an error rate of 2.44%. The main cause of error was incorrect interpretation of the pathologic findings. In the present study, frozen sections showed good sensitivity (97.98%) and specificity (97.16%). Despite its limitations, frozen section is still generally considered to be an accurate mode of intraoperative consultation to assist the surgeon in deciding the best therapeutic approach for his patient at the operating table. The use of frozen section with proper indications was cost-effective as it helped lower the number of reoperations. An audit of intraoperative frozen section from time to time serves as part of an ongoing quality assurance program and should be recommended where the service is available.
    Matched MeSH terms: Pathology, Surgical/standards*