Displaying all 11 publications

Abstract:
Sort:
  1. Ismail MD, Han CK, Loch A
    Cardiovasc Intervent Radiol, 2016 May;39(5):785-787.
    PMID: 26757911 DOI: 10.1007/s00270-015-1290-1
    Matched MeSH terms: Percutaneous Coronary Intervention/instrumentation*
  2. Leschke M, Waliszewski M, Pons M, Champin S, Nait Saidi L, Mok Heang T, et al.
    Catheter Cardiovasc Interv, 2016 Sep;88(3):358-66.
    PMID: 26650913 DOI: 10.1002/ccd.26261
    OBJECTIVES: This observational study assessed the 9-month clinical outcomes in an « all comers » population with a focus on patients with atrial fibrillation (AF) after thin strut bare metal stenting.

    BACKGROUND: Drug eluting stent (DES) implantation is the treatment of choice for coronary artery disease (CAD) leaving only marginal indications for the use of bare metal stents (BMS). However, selected treatment populations with DES contraindications such as patients who cannot sustain 6-12 months of dual antiplatelet therapy (DAPT) remain candidates for BMS implantations.

    METHODS: Thin strut bare metal stenting in a priori defined subgroups were investigated in a non-randomized, international, multicenter «all comers» observational study. Primary endpoint was the 9-month TLR rate whereas secondary endpoints included the 9-month MACE and procedural success rates.

    RESULTS: A total of 783 patients of whom 98 patients had AF underwent BMS implantation. Patient age was 70.4 ± 12.8 years. Cardiovascular risk factors in the overall population were male gender (78.2%, 612/783), diabetes (25.2%, 197/783), hypertension (64.1%, 502/783), cardiogenic shock (4.9%, 38/783) and end stage renal disease (4.9%, 38/783). In-hospital MACE was 4.1% (30/783) in the overall population. The 9-month TLR rate was 4.5% (29/645) in the non-AF group and 3.3% (3/90) in the AF group (P = 0.613). At 9 months, the MACE rate in the AF-group and non-AF group was not significantly different either (10.7%, 69/645 vs. 6.7%, 6/90; P = 0.237). Accumulated stroke rates were 0.3% (2/645) in the non-AF subgroup at baseline and 1.1% (1/90) in the AF subgroup (P = 0.264).

    CONCLUSION: Bare metal stenting in AF patients delivered acceptably low TLR and MACE rates while having the benefit of a significantly shorter DAPT duration in a DES dominated clinical practice. © 2015 Wiley Periodicals, Inc.

    Matched MeSH terms: Percutaneous Coronary Intervention/instrumentation*
  3. Haude M, Lee SWL, Worthley SG, Silber S, Verheye S, Rosli MA, et al.
    Catheter Cardiovasc Interv, 2020 05 01;95(6):1076-1084.
    PMID: 31489742 DOI: 10.1002/ccd.28483
    OBJECTIVES: To evaluate the long-term safety and efficacy of the novel combined sirolimus-eluting endothelial progenitor cell capture Combo stent (OrbusNeich, Fort Lauderdale, FL) at 5 years in the REMEDEE (Randomized study to Evaluate the safety and effectiveness of an abluMinal sirolimus coated bio-Engineered stEnt) trial.

    BACKGROUND: Drug-eluting stents have limited restenosis and reintervention but are complicated by late and very late thrombosis and accelerated neoatherosclerosis. Alternative or adjunctive technologies are needed to address these limitations.

    METHODS: A total of 183 patients with de novo lesions in native coronary arteries were randomized 2:1 to Combo (n = 124) or Taxus Liberté (n = 59). Primary endpoint was 9 month angiographic in-stent late lumen loss and the secondary endpoint was the occurrence of major adverse events (MACE) through 5-year follow-up.

    RESULTS: Compared with Taxus, after 5 years the Combo stent was associated with similar rates of MACE (18.3% vs. 16.9%, p = .89), cardiac death (0.8% vs. 5.1%, p = .07), myocardial infarction (4.1% vs. 3.4%, p = .81), target lesion (9.4% vs. 10.2%, p = .78), and target vessel revascularization (14.4% vs. 11.9%, p = .73). No cases of definite stent thrombosis were reported in the Combo group. The follow-up rate at 5 years was 97.7%.

    CONCLUSION: At 5-year follow-up, the Combo stent remained clinically safe and effective with an overall low rate of MACE comparable to Taxus.

    Matched MeSH terms: Percutaneous Coronary Intervention/instrumentation*
  4. Tenekecioglu E, Serruys PW, Onuma Y, Costa R, Chamié D, Sotomi Y, et al.
    JACC Cardiovasc Interv, 2017 06 12;10(11):1115-1130.
    PMID: 28527768 DOI: 10.1016/j.jcin.2017.03.015
    OBJECTIVES: The primary objective of this study was to evaluate the safety and effectiveness of the Mirage (Manli Cardiology, Singapore) bioresorbable microfiber sirolimus-eluting scaffold compared with the Absorb (Abbott Vascular, Santa Clara, California) bioresorbable vascular scaffold in the treatment of stenotic target lesions located in native coronary arteries, ranging from ≥2.25 to ≤4.0 mm in diameter. Secondary objectives were to establish the medium-term safety, effectiveness, and performance of the Mirage device.

    BACKGROUND: The current generation of bioresorbable scaffolds has several limitations, such as thick square struts with large footprints that preclude their deep embedment into the vessel wall, resulting in protrusion into the lumen with microdisturbance of flow. The Mirage sirolimus-eluting bioresorbable microfiber scaffold is designed to address these concerns.

    METHODS: In this prospective, single-blind trial, 60 patients were randomly allocated in a 1:1 ratio to treatment with a Mirage sirolimus-eluting bioresorbable microfiber scaffold or an Absorb bioresorbable vascular scaffold. The clinical endpoints were assessed at 30 days and at 6 and 12 months. In-device angiographic late loss at 12 months was quantified. Secondary optical coherence tomographic endpoints were assessed post-scaffold implantation at 6 and 12 months.

    RESULTS: Median angiographic post-procedural in-scaffold minimal luminal diameters of the Mirage and Absorb devices were 2.38 mm (interquartile range [IQR]: 2.06 to 2.62 mm) and 2.55 mm (IQR: 2.26 to 2.71 mm), respectively; the effect size (d) was -0.29. At 12 months, median angiographic in-scaffold minimal luminal diameters of the Mirage and Absorb devices were not statistically different (1.90 mm [IQR: 1.57 to 2.31 mm] vs. 2.29 mm [IQR: 1.74 to 2.51 mm], d = -0.36). At 12-month follow-up, median in-scaffold late luminal loss with the Mirage and Absorb devices was 0.37 mm (IQR: 0.08 to 0.72 mm) and 0.23 mm (IQR: 0.15 to 0.37 mm), respectively (d = 0.20). On optical coherence tomography, post-procedural diameter stenosis with the Mirage was 11.2 ± 7.1%, which increased to 27.4 ± 12.4% at 6 months and remained stable (31.8 ± 12.9%) at 1 year, whereas the post-procedural optical coherence tomographic diameter stenosis with the Absorb was 8.4 ± 6.6%, which increased to 16.6 ± 8.9% and remained stable (21.2 ± 9.9%) at 1-year follow-up (Mirage vs. Absorb: dpost-procedure = 0.41, d6 months = 1.00, d12 months = 0.92). Angiographic median in-scaffold diameter stenosis was significantly different between study groups at 12 months (28.6% [IQR: 21.0% to 40.7%] for the Mirage, 18.2% [IQR: 13.1% to 31.6%] for the Absorb, d = 0.39). Device- and patient-oriented composite endpoints were comparable between the 2 study groups.

    CONCLUSIONS: At 12 months, angiographic in-scaffold late loss was not statistically different between the Mirage and Absorb devices, although diameter stenosis on angiography and on optical coherence tomography was significantly higher with the Mirage than with the Absorb. The technique of implantation was suboptimal for both devices, and future trials should incorporate optical coherence tomographic guidance to allow optimal implantation and appropriate assessment of the new technology, considering the novel mechanical properties of the Mirage.

    Matched MeSH terms: Percutaneous Coronary Intervention/instrumentation*
  5. Montefusco A, D'Ascenzo F, Gili S, Smolka G, Chieffo A, Baumbach A, et al.
    Catheter Cardiovasc Interv, 2019 02 01;93(2):208-215.
    PMID: 30298593 DOI: 10.1002/ccd.27809
    OBJECTIVES: To compare the effectiveness and safety of self-expandable, sirolimus-eluting Stentys stents (SES) and second-generation drug-eluting stents (DES-II) for the treatment of the unprotected left main (ULM).

    BACKGROUND: SES may provide a valuable option to treat distal ULM, particularly when significant caliber gaps with side branches are observed.

    METHODS: Patients from the multicenter SPARTA (clinicaltrials.gov: NCT02784405) and FAILS2 registries were included. Propensity-score with matching was performed to account for the lack of randomization. Primary end-point was the rate of major adverse cardiovascular events (MACE, a composite of all cause death, myocardial infarction, target lesion revascularization [TLR], unstable angina and definite stent thrombosis [ST]). Single components of MACE were the secondary end-points.

    RESULTS: Overall, 151 patients treated with SES and 1270 with DES-II were included; no differences in MACE rate at 250 days were observed (9.8% vs. 11.5%, P = 0.54). After propensity score with matching, 129 patients treated with SES and 258 with DES-II, of which about a third of female gender, were compared. After a follow-up of 250 days, MACE rate did not differ between the two groups (9.9% vs. 8.5%, P = 0.66), as well as the rate of ULM TLR (1.6% vs. 3.1%, P = 0.36) and definite ST (0.8% vs. 1.2%, P = 0.78). These results were consistent also when controlling for the treatment with provisional vs. 2-stents strategies for the ULM bifurcation.

    CONCLUSION: SES use for ULM treatment was associated with a similar MACE rate compared to DES-II at an intermediate-term follow-up. SES might represent a potential option in this setting.

    Matched MeSH terms: Percutaneous Coronary Intervention/instrumentation*
  6. Ali RM, Abdul Kader MASK, Wan Ahmad WA, Ong TK, Liew HB, Omar AF, et al.
    JACC Cardiovasc Interv, 2019 Mar 25;12(6):558-566.
    PMID: 30898253 DOI: 10.1016/j.jcin.2018.11.040
    OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB).

    BACKGROUND: Treatment of coronary in-stent restenosis (ISR) remains challenging. PCBs are an established treatment option outside the United States with a Class I, Level of Evidence: A recommendation in the European guidelines. However, their efficacy is better in bare-metal stent (BMS) ISR compared with drug-eluting stent (DES) ISR.

    METHODS: Fifty patients with DES ISR were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, 4 μg/mm2) with a clinically proven PCB (SeQuent Please Neo, 3 μg/mm2) in coronary DES ISR. The primary endpoint was angiographic late lumen loss at 6 months. Secondary endpoints included procedural success, major adverse cardiovascular events, and individual clinical endpoints such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis.

    RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.21 ± 0.54 mm in the PCB group versus 0.17 ± 0.55 mm in the SCB group (p = NS; per-protocol analysis). Clinical events up to 12 months also did not differ between the groups.

    CONCLUSIONS: This first-in-man comparison of a novel SCB with a crystalline coating shows similar angiographic outcomes in the treatment of coronary DES ISR compared with a clinically proven PCB. (Treatment of Coronary In-Stent Restenosis by a Sirolimus [Rapamycin] Coated Balloon or a Paclitaxel Coated Balloon [FIM LIMUS DCB]; NCT02996318).

    Matched MeSH terms: Percutaneous Coronary Intervention/instrumentation*
  7. Krackhardt F, Waliszewski M, Kočka V, Toušek P, Janek B, Hudec M, et al.
    Cardiovasc Drugs Ther, 2020 06;34(3):335-344.
    PMID: 32212061 DOI: 10.1007/s10557-020-06963-5
    OBJECTIVES: The objective of this post hoc analysis was to analyze real-world dual antiplatelet therapy (DAPT) regimens following polymer-free sirolimus-eluting stent (PF-SES) implantations in an unselected patient population.

    METHODS: Patient-level data from two all-comers observational studies (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled and analyzed in terms of their primary endpoint. During the data verification process, we observed substantial deviations from DAPT guideline recommendations. To illuminate this gap between clinical practice and guideline recommendations, we conducted a post hoc analysis of DAPT regimens and clinical event rates for which we defined the net adverse event rate (NACE) consisting of target lesion revascularization (TLR, primary endpoint of all-comers observational studies) all-cause death, myocardial infarction (MI), stent thrombosis (ST), and bleeding events. A logistic regression was utilized to determine predictors why ticagrelor was used in stable coronary artery disease (CAD) patients instead of the guideline-recommended clopidogrel.

    RESULTS: For stable CAD, the composite endpoint of clinical, bleeding, and stent thrombosis, i.e., NACE, between the clopidogrel and ticagrelor treatment groups was not different (5.4% vs. 5.1%, p = 0.745). Likewise, in the acute coronary syndrome (ACS) cohort, the NACE rates were not different between both DAPT strategies (9.2% vs. 9.3%, p = 0.927). There were also no differences in the accumulated rates for TLR, myocardial infarction ([MI], mortality, bleeding events, and stent thrombosis in elective and ACS patients. The main predictors for ticagrelor use in stable CAD patients were age

    Matched MeSH terms: Percutaneous Coronary Intervention/instrumentation*
  8. Krackhardt F, Rosli MA, Leschke M, Schneider A, Sperling C, Heang TM, et al.
    Catheter Cardiovasc Interv, 2018 06;91(7):1221-1228.
    PMID: 28944613 DOI: 10.1002/ccd.27306
    OBJECTIVE: The objective of this study was to compare the safety and efficacy of a polymer-free sirolimus coated, ultrathin strut drug eluting stent (PF-SES) to its uncoated bare-metal stent (BMS) platform of identical stent architecture.

    BACKGROUND: Recently published randomized trials comparing BMS to DES with a focus on shortened dual-antiplatelet therapy reported incidences of stent thrombosis (ST) and bleeding complications (LEADERS FREE) in favor of drug eluting stents (DES).

    METHODS: Data of previously published large-sale, international, single-armed, multicenter, observational studies of ultra-thin PF-SES, and BMS were propensity score (PS) matched for selected lesion morphological and cardiovascular risk factors to compare target lesion revascularization (TLR), myocardial infarction, cardiac death, major adverse cardiac events (MACE), bleeding complications and ST rates. Primary endpoint in both studies was TLR at 9 months.

    RESULTS: At 9 months the rates of TLR was significantly lower in the PF-SES group as compared with patients treated with the BMS analogue of identical stent design (1.4% vs. 4.6%, P = 0.005). Likewise the 9-month MACE rates were lower in the PF-SES group (3.2% vs. 8.7%, P = 0.001) whereas there were no differences in the accumulated ST rates (0.5% vs. 1.5%, P = 0.109). Overall accumulated bleeding incidences (BARC 1-5) were not significantly different between PF-SES and BMS patients (1.8% vs. 2.7%, p = 0.388).

    CONCLUSIONS: PF-SES are superior over analogue BMS of identical stent architecture in daily clinical routine with lower rates of TLR and MACE in a PS-matched, unselected patient population without differences in accumulated ST rates and bleeding frequencies given the currently favored postprocedural comedication (ClinicalTrials.gov Identifier NCT02629575).

    Matched MeSH terms: Percutaneous Coronary Intervention/instrumentation*
  9. Krackhardt F, Kočka V, Waliszewski M, Toušek P, Janek B, Trenčan M, et al.
    Medicine (Baltimore), 2020 Feb;99(8):e19119.
    PMID: 32080086 DOI: 10.1097/MD.0000000000019119
    Stent designs with ultrathin struts may further increase the procedural success of challenging lesion subsets. The objective of this study was to assess the safety and efficacy of ultrathin strut, polymer-free sirolimus eluting stent (PF-SES) implantations in a large scale, unselected patient population.Adult patients underwent percutaneous coronary interventions (PCI) with a thin-strut PF-SES. Data from two all-comers observational studies having the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled. The accumulated target lesion revascularization (TLR) rate at 9-12 months was the primary endpoint. All dual antiplatelet therapy strategies according to the applicable guidelines were permissible.In total, 7243 patients were prospectively enrolled for PCI with PF-SES in stable coronary artery disease or acute coronary syndrome (ACS). Major risk factors in the overall cohort were diabetes (37.3%), ST elevation myocardial infarction (18.1%) and non-ST myocardial infarction (24.6%). The follow-up rate was 88.6% in the overall population. The TLR rate in the overall cohort was 2.2% whereas definite/probable stent thrombosis (ST) occurred in 0.7%. In patients with in-stent restenosis lesions, the major adverse cardiac events rate was 6.4% whereas the corresponding rate for isolated left main coronary artery (LMCA) disease was highest with 6.7% followed by patients with culprit lesions in vein bypasses (VB, 7.1%). The mortality rate in patients treated in VB lesions was highest with 5.4%, followed by the isolated LMCA subgroup (3.4%) and ACS (2.6%).PCI with PF-SES in an unselected patient population, is associated with low clinical event and ST rates. Furthermore, PF-SES angioplasty in niche indications demonstrated favorable safety and efficacy outcomes with high procedural success rates.
    Matched MeSH terms: Percutaneous Coronary Intervention/instrumentation*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links