Displaying all 2 publications

Abstract:
Sort:
  1. Shanmuganathan G, Ritz MA, Holloway RH, Di Matteo AC, Omari TI
    J Gastroenterol Hepatol, 2000 Dec;15(12):1362-9.
    PMID: 11197044
    BACKGROUND AND AIMS: Perfused miniature manometric assemblies with lumina of 0.4-0.5 mm i.d. have been developed. Reduced luminal size offers the advantages of reduced assembly bulk and increased assembly complexity with greater numbers of lumina and lower manometric infusion volumes because of a slower perfusion rate. This study investigated the recording fidelity of miniature manometric assemblies in the measurement of esophageal peristalsis.

    METHODS: Four miniature manometric assemblies, each containing manometric lumina of either 0.4 or 0.5 mm i.d., were evaluated at 100 and 180 cm lengths. The fidelity of miniature manometric luminal recordings were evaluated in vivo during esophageal peristalsis by using a simultaneous comparison with the standard lumina and an intraluminal strain gauge.

    RESULTS: During esophageal peristalsis, miniature manometric lumina recorded the peak amplitude of pressure waves, with an accuracy at perfusion rates of 0.04 mL/min (0.4 mm, i.d.) and 0.15 mL/min (0.5 mm, i.d.).

    CONCLUSION: Miniature manometric assemblies of lengths that are practical for use in humans are suitable for recording esophageal peristalsis.

    Matched MeSH terms: Peristalsis/physiology*
  2. Mohd Said MR, Wong Z, Abdul Rani R, Ngiu CS, Raja Ali RA, Lee YY
    J Gastroenterol Hepatol, 2021 May;36(5):1244-1252.
    PMID: 33002243 DOI: 10.1111/jgh.15284
    BACKGROUND AND AIM: Variations in the Chicago 3.0 normative metrics may exist with different postures and with different provocative swallow materials in a healthy Asian population.

    METHOD: Eligible healthy Malay volunteers were invited to undergo the high-resolution esophageal manometry (inSIGHT Ultima, Diversatek Healthcare, Milwaukee, WI, USA). In recumbent and standing positions, test swallows were performed using liquid, viscous, and solid materials. Metrics including integrated relaxation pressure 4 s (IRP-4 s, mmHg), distal contractile integral (DCI, mmHg s cm), distal latency (DL, s), and peristaltic break (PB, cm) were reported in median and 95th percentile.

    RESULTS: Fifty of 57 screened participants were recruited, and 586 saline, 265 viscous, and 261 solid swallows were analyzed. Per-patient wise, in the recumbent position, 95th percentile for IRP-4 s, DCI, DL, and PB were 16.5 mmHg, 2431 mmHg s cm, 8.5 s, and 7.2 cm, respectively. We observed that with each posture, the use of viscous swallows led to changes in DL, but the use of solid swallows led to more changes in the metrics including DCI and length of PB. Compared with a recumbent posture, anupright posture led to lower IRP-4 s and DCI values. Both per-patient analysis and per-swallow analyses yielded almost similar results when comparing the different postures and types of swallows. No major motility disorders were observed in this cohort of asymptomatic population. However, more motility disorders were reported in the upright position.

    CONCLUSIONS: Variations in metrics can be observed in different postures and with different provocative swallow materials in a healthy population. The normative Chicago 3.0 metrics are also determined for the Malay population.

    Matched MeSH terms: Peristalsis/physiology
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links