Displaying all 2 publications

Abstract:
Sort:
  1. Cheah PY, Yuen KH, Liong ML
    J Chromatogr B Biomed Sci Appl, 2000 Aug 18;745(2):439-43.
    PMID: 11043762
    A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25-100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25-100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.
    Matched MeSH terms: Prazosin/pharmacokinetics
  2. Loh GOK, Wong EYL, Tan YTF, Ong LM, Ng RS, Wee HC, et al.
    PMID: 33429127 DOI: 10.1016/j.jchromb.2020.122517
    A simple, fast and sensitive LC-MS/MS method was developed to quantify terazosin in human plasma. The mobile phase consisted of acetonitrile-0.1% (v/v) formic acid (70:30, v/v). Prazosin was used as internal standard (IS). As deproteinization agent, acetonitrile produced a clean sample. A higher response intensity with more symmetrical peak was obtained using Agilent Poroshell 120 EC-C18 - Fast LC column (100 × 2.1mmID, 2.7 μm) compared with Kinetex XB-C18 (100 × 2.1 mm, 2.6 µm) column. The response of terazosin and IS were approximately two times in citrate phosphate dextrose (CPD) plasma compared with dipotassium ethylenediaminetetraacetic acid (K2EDTA) plasma. Plasma calibration curve was linear from 1.0 to 100.0 ng/mL, with coefficient of determination r2 ≥ 0.99. The within-run and between-run precision values (CV, %) were <5.2% and <7.8%, while accuracy values were 102.8-112.7% and 103.4-112.2%. The extended run accuracy was 98.6-102.8% and precision (CV, %) 4.3-10.4%. The recovery of analyte was >98% and IS >94%. Terazosin in plasma kept at benchtop was stable for 24 h, in autosampler tray for 48 h, in instrumentation room for 48 h, for 7 freeze-thaw cycles and in freezer for 140 days. Terazosin and IS stock standard solutions were stable for 140 days at room temperature and in the chiller. The high throughput method was successfully utilized to measure 935 samples in a bioequivalence study of terazosin.
    Matched MeSH terms: Prazosin/pharmacokinetics
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links