Displaying all 3 publications

Abstract:
Sort:
  1. Mahyuddin NM, Russell G
    ScientificWorldJournal, 2014;2014:876435.
    PMID: 24782671 DOI: 10.1155/2014/876435
    Technology scaling relies on reduced nodal capacitances and lower voltages in order to improve performance and power consumption, resulting in significant increase in layout density, thus making these submicron technologies more susceptible to soft errors. Previous analysis indicates a significant improvement in SEU tolerance of the driver when the bias current is injected into the circuit but results in increase of power dissipation. Subsequently, other alternatives are considered. The impact of transistor sizes and temperature on SEU tolerance is tested. Results indicate no significant changes in Q(crit) when the effective transistor length is increased by 10%, but there is an improvement when high temperature and high bias currents are applied. However, this is due to other process parameters that are temperature dependent, which contribute to the sharp increase in Q(crit). It is found that, with temperature, there is no clear factor that can justify the direct impact of temperature on the SEU tolerance. Thus, in order to improve the SEU tolerance, high bias currents are still considered to be the most effective method in improving the SEU sensitivity. However, good trade-off is required for the low-swing driver in order to meet the reliability target with minimal power overhead.
    Matched MeSH terms: Radiation Monitoring/instrumentation
  2. Alashrah S, Kandaiya S, Maalej N, El-Taher A
    Radiat Prot Dosimetry, 2014 Dec;162(3):338-44.
    PMID: 24300340 DOI: 10.1093/rpd/nct315
    Estimation of the surface dose is very important for patients undergoing radiation therapy. The purpose of this study is to investigate the dose at the surface of a water phantom at a depth of 0.007 cm as recommended by the International Commission on Radiological Protection and International Commission on Radiation Units and Measurement with radiochromic films (RFs), thermoluminescent dosemeters and an ionisation chamber in a 6-MV photon beam. The results were compared with the theoretical calculation using Monte Carlo (MC) simulation software (MCNP5, BEAMnrc and DOSXYZnrc). The RF was calibrated by placing the films at a depth of maximum dose (d(max)) in a solid water phantom and exposing it to doses from 0 to 500 cGy. The films were scanned using a transmission high-resolution HP scanner. The optical density of the film was obtained from the red component of the RGB images using ImageJ software. The per cent surface dose (PSD) and percentage depth dose (PDD) curve were obtained by placing film pieces at the surface and at different depths in the solid water phantom. TLDs were placed at a depth of 10 cm in a solid water phantom for calibration. Then the TLDs were placed at different depths in the water phantom and were exposed to obtain the PDD. The obtained PSD and PDD values were compared with those obtained using a cylindrical ionisation chamber. The PSD was also determined using Monte Carlo simulation of a LINAC 6-MV photon beam. The extrapolation method was used to determine the PSD for all measurements. The PSD was 15.0±3.6% for RF. The TLD measurement of the PSD was 16.0±5.0%. The (0.6 cm(3)) cylindrical ionisation chamber measurement of the PSD was 50.0±3.0%. The theoretical calculation using MCNP5 and DOSXYZnrc yielded a PSD of 15.0±2.0% and 15.7±2.2%. In this study, good agreement between PSD measurements was observed using RF and TLDs with the Monte Carlo calculation. However, the cylindrical chamber measurement yielded an overestimate of the PSD. This is probably due to the ionisation chamber calibration factor that is only valid in charged particle equilibrium condition, which is not achieved at the surface in the build-up region.
    Matched MeSH terms: Radiation Monitoring/instrumentation*
  3. Aziz Saleh M, Termizi Ramli A, Alajerami Y, Damoom M, Sadiq Aliyu A
    Isotopes Environ Health Stud, 2014;50(1):103-13.
    PMID: 24279290 DOI: 10.1080/10256016.2013.821469
    The radiation survey of the ambient environment was conducted using two gamma detectors, and the measurement results were used in the computation of the mean external radiation dose rate, mean-weighted dose rate and annual effective dose, which are 144 nGy h(-1), 0.891 mSv y(-1) and 178 μSv, respectively. A high-purity germanium detector was used to determine the activity concentrations of (232)Th, (226)Ra and (40)K in soil samples. The results of the gamma spectrometry of the soil samples show radioactivity concentration ranges from 19±1 to 405±13 Bq kg(-1) with a mean value of 137±5 Bq kg(-1) for (232)Th, from 21±2 to 268±9 Bq kg(-1)with a mean value of 78±3 Bq kg(-1) for (226)Ra and from 23±9 to 1268±58 Bq kg(-1) with a mean value of 207±13 Bq kg(-1) for (40)K. Radium equivalent activity (Raeq) and external hazard index (Hex) were 290 Bq kg(-1) and 0.784, respectively, which were safe for the population. The mean lifetime dose and lifetime cancer risk for each person living in the area with average lifetime (70 y) were 12.46 mSv and 7.25×10(-4) Sv year, respectively. The results were compared with values given in United Nations Scientific Committee on the Effects of Atomic Radiation 2000.
    Matched MeSH terms: Radiation Monitoring/instrumentation
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links