Improvements in delivery of radiation dose to target tissues in radiotherapy have increased the need for better image quality and led to a higher frequency of imaging patients. Imaging for treatment planning extends to function and motion assessment and devices are incorporated into medical linear accelerators (linacs) so that regions of tissue can be imaged at time of treatment delivery to ensure dose distributions are delivered as accurately as possible. A survey of imaging in 97 radiotherapy centres in nine countries on six continents has been undertaken with an on-line questionnaire administered through the International Commission on Radiological Protection mentorship programme to provide a snapshot of imaging practices. Responses show that all centres use CT for planning treatments and many utilise additional information from magnetic resonance imaging and positron emission tomography scans. Most centres have kV cone beam CT attached to at least some linacs and use this for the majority of treatment fractions. The imaging options available declined with the human development index (HDI) of the country, and the frequency of imaging during treatment depended more on country than treatment site with countries having lower HDIs imaging less frequently. The country with the lowest HDI had few kV imaging facilities and relied on MV planar imaging intermittently during treatment. Imaging protocols supplied by vendors are used in most centres and under half adapt exposure conditions to individual patients. Recording of patient doses, a knowledge of which is important in optimisation of imaging protocols, was limited primarily to European countries.
This work evaluated and compared the absorbed doses to selected organs in the head and neck region from the three image guided radiotherapy systems: cone-beam computed tomography (CBCT) and kilovoltage (kV) planar imaging using the On-board Imager® (OBI) as well as the ExacTrac® X-ray system, all available on the Varian Novalis TX linear accelerator. The head and neck region of an anthropomorphic phantom was used to simulate patients' head within the imaging field. Nanodots optically stimulated luminescent dosemeters were positioned at selected sites to measure the absorbed doses. CBCT was found to be delivering the highest dose to internal organs while OBI-2D gave the highest doses to the eye lenses. The setting of half-rotation in CBCT effectively reduces the dose to the eye lenses. Daily high-quality CBCT verification was found to increase the secondary cancer risk by 0.79%.