Displaying all 2 publications

Abstract:
Sort:
  1. Park KS, Seon JK, Lee KB, Kim SK, Chan CK, Yoon TR
    J Arthroplasty, 2017 02;32(2):503-509.
    PMID: 27546473 DOI: 10.1016/j.arth.2016.07.010
    BACKGROUND: This study aims at determining the average long-term result of revision total hip arthroplasty (THA) using the acetabular reinforcement ring with a hook (ARRH) and bone grafting in severe acetabular bony defect. Expected 15-year survival of ARRH in revision THA is included in the study.

    METHODS: Retrospective review of 48 patients (48 hips) with follow-up duration of average 11.4 years (range, 6.1-21.4 years) was conducted. At each follow-up, Harris hip score was used to assess functional outcome, and radiographic acetabular component osteolysis was measured by DeLee and Charnley classification. Bone defects were assessed preoperatively and intraoperatively using American academy of orthopedic surgeons and Paprosky classification. The common modes of ARRH failures were evaluated. Bone consolidation, presence of heterotopic ossification, and complications such as infection and dislocation were recorded.

    RESULTS: The bone defects were varied and included cavitary, segmental, and combined defects without any pelvic discontinuity. Mean Harris hip score improved from 52.6 points preoperatively to 82.0 points postoperatively. Nine acetabular revisions and 3 stem revisions (2 concurrent with acetabular revisions and 1 isolated stem revision) were performed. There were 5 infected cases and 1 patient with recurrent dislocation. The 11.4-year survival of revision THA with ARRH was 71% as the end point for acetabular revision surgery for any reason. The expected 15-year survival of revision THA with ARRH was 60%. The most common failure mode of ARRH was superomedial migration followed by lateral migration.

    CONCLUSION: ARRH combined with bone grafting produces relatively good average long-term clinical results.

    Matched MeSH terms: Reoperation/instrumentation*
  2. Park KS, Chan CK, Kim SK, Li QS, Im CJ, Yoon TR
    J Orthop Sci, 2019 May;24(3):452-457.
    PMID: 30415823 DOI: 10.1016/j.jos.2018.10.016
    BACKGROUND: Due to concern of potential metallosis caused by residual microscopic ceramic particles, metal-on-metal (MoM) bearing is deemed undesirable in revision total hip arthroplasty (THA) for ceramic bearing fracture. We determined whether MoM bearing is suitable to be used in revision THA for ceramic fractures and also evaluated whether this treatment increases serum iron levels compared with MoM bearing revision THA for polyethylene failure.

    METHODS: Between 2006 and 2012, 22 patients underwent revision surgery using MoM bearing (28 mm femoral head in 18 hips and 32 mm in 4 hips) for ceramic bearing fracture and followed average 52.1 months. We assessed radiological parameter and functional outcome using Harris hip score (HHS) and WOMAC score. Also, serum cobalt (Co) and chromium (Cr) blood tests were performed and compared with the result obtained from age, sex- and follow-up duration-matched patients with MoM revision THA for failed polyethylene bearing.

    RESULTS: The mean HHS improved from 60.6 preoperatively to 90.3 at final follow-up. There were no changes in cup position, progression of osteolytic lesions, and measurable wear of MoM bearing articulation at final follow-up radiographs. There was one case of recurrent dislocation after surgery, which was treated with greater trochanter distal advancement and one case of deep infection, which underwent two-stage revision. Mean serum Co level (1.7 vs. 1.4 μg/dl; p = 0.211) and Cr level (0.70 vs. 1.01 μg/dl; p = 0.327) showed no significant difference.

    CONCLUSIONS: MoM articulation with liner cementation into the acetabular cup along with total synovectomy can be chosen in revision surgery for ceramic fracture with good midterm follow-up. However, the use of MoM bearing is indicated when the stem and metal shell can be retained and ceramic on ceramic or ceramic on polyethylene bearing cannot be selected. Also long-term outcome needs to be further evaluated.

    Matched MeSH terms: Reoperation/instrumentation
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links