  1. Harvinder S, Hassan S, Sidek DS, Hamzah M, Samsudin AR, Philip R
    Med J Malaysia, 2005 Dec;60(5):585-9.
    PMID: 16515109
    Human amniotic membrane as a homograft material was compared to temporalis fascia to close tympanic membrane perforations in 50 patients with chronic otitis media. Human amniotic membrane was used in 20 patients while temporalis fascia was used in the remaining 30. Anatomical closure of the perforation and reduction of the air-bone gap was measured. The graft uptake showed a 65% success rate for the amniotic membrane and 56.7% for the temporalis fascia at 3 months post-operatively. Significant closure of air-bone gap was observed in the human amniotic group. These results indicate comparable outcomes between human amniotic membrane and the temporalis fascia graft.
    Matched MeSH terms: Temporal Muscle/transplantation