Incomplete involution of valve of systemic venous sinus can present across a spectrum of anatomical lesions ranging from eustachian valve to division of right atrium (cor triatriatum dexter) with overlapping features. We present the case of a neonate presenting with cyanosis, having persistent valve of systemic venous sinus with anatomical details of the redundant tissue in right atrium suggesting an intermediate form between Chiari network and division of right atrium.
OBJECTIVES: The aim of this study was to evaluate if emergency medicine trainees with a short duration of training in echocardiography could perform and interpret bedside-focused echocardiography reliably on emergency department patients.
METHODS: Following a web-based learning module and 3 h of proctored practical training, emergency medicine trainees were evaluated in technical and interpretative skills in estimating left ventricular function, detection of pericardial effusion and inferior vena cava (IVC) diameter measurements using bedside-focused echocardiography on emergency department patients. An inter-rater agreement analysis was performed between the trainees and a board-certified cardiologist.
RESULTS: 100 focused echocardiography examinations were performed by nine emergency medicine trainees. Agreement between the trainees and the cardiologist was 93% (K=0.79, 95% CI 0.773 to 0.842) for visual estimation of left ventricular function, 92.9% (K=0.80, 95% CI 0.636 to 0.882) for quantitative left ventricular ejection fraction by M-mode measurements, 98% (K=0.74, 95% CI 0.396 to 1.000) for the detection of pericardial effusion, and 64.2% (K=0.45, 95% CI 0.383 to 0.467) for IVC diameter assessment. The Bland-Altman limits of agreement for left ventricular function was -9.5% to 13.7%, and a Pearson's correlation yielded a value of 0.82 (p<0.0001, 95% CI 0.734 to 0.881). The trainees detected pericardial effusion with a sensitivity of 60%, specificity of 100%, positive predictive value of 100% and negative predictive value of 97.9%.
CONCLUSIONS: Emergency medicine trainees were found to be able to perform and interpret focused echocardiography reliably after a short duration of training.
Study site: Trauma and emergency department, University of Malaya Medical Centre, Kuala Lumpur