A cross-sectional bacteriological survey of cattle in West Malaysia revealed 14.4% (32/222) had leptospiral infection. Isolates were obtained from all except one herd with prevalence of infection in herds ranging from 0-44.8%. A small number of buffalo urine samples were examined and all of them were found to be negative. A leptospiral isolate obtained from a bovine kidney proved to be a new serovar of Leptospira interrogans and the name unipertama was assigned to it. Six other leptospiral serovars were isolated, namely canicola, australis, javanica, ballum, pomona and hardjo. All six serovars were isolated for the first time in cattle in Malaysia. Cattle in Malaysia appear to be the maintenance host for serovar hardjo. The presence of the other serovars in cattle was probably due to contact with the maintenance hosts, pigs for serovar pomona and rodents for the other three serovars. It appears that the epidemiology of leptospiral infection in cattle in Malaysia is similar to that reported overseas.
The aim of the study was to look into the epidemiology of serodiagnosed cases of leptospirosis at the University Hospital and compare two commercial ELISA Assays to the Microscopic Agglutination Test (MAT). Demographic data for all serodiagnosed cases for the years 1991-1997 were collected. From this data, 104 sera (n = 104) were selected as samples for comparative evaluation of the commercial ELISAs (INDX Dip-S-Ticks and PanBio ELISA) to the MAT test. Thirty two (n = 32) negative control sera were selected from serodiagnosed cases of other differential diagnosis of leptospira infection. The MAT test is a standard test that detects agglutination antibodies to leptospira biflexa, while the INDX Dip-S-Ticks is an ELISA dot test assaying for total anti-leptospira antibodies. The PanBio ELISA is a colorometric assay in test well strips to detect anti-leptospira IgM. The sensitivity, specificity, and efficiency of tests were calculated at a MAT cut-off value of 1:320. Demographic data showed that leptospirosis peaks during March-May and Aug-Nov coinciding with the inter-monsoon period with more men being infected than women and more adults than children. The sensitivity, specificity, and efficiency of test for the INDX Dip-S-Ticks were 83.3%, 93.8% and 87.5% while the values for the PanBio ELISA were 54.2%, 96.9% and 71.3%. The suboptimal PanBio result could be related to the blocking effect of high IgG titres or could be related to the diagnostic MAT cut-off values used in this study. The data hence reflects a pattern of transmission that is related to "wet" occupational risk factors. The commercial assays evaluated, are easier to perform but interpretation of results should be based on level of endemicity. The INDX Dip-S-Ticks allows this flexibility and is a practical alternative to the MAT test.