Displaying all 5 publications

Abstract:
Sort:
  1. Bong YU, Kuppuswamy R
    Forensic Sci Int, 2010 Feb 25;195(1-3):86-92.
    PMID: 20022189 DOI: 10.1016/j.forsciint.2009.11.018
    Restoration of obliterated engraved marks on high strength Al-Zn-Mg-Cu alloy (AA7010) surfaces by etching technique was studied. The alloy surfaces were mechanically engraved with some identification marks using "Gravograph". The marks were then erased by removing the metal to different levels up to and below the depth of engraving. Five metallographic reagents were tested on the obliterated surfaces by etching. The following two methods (i) immersion in 10% aq. phosphoric acid and (ii) alternate swabbing of 60% HCl and 40% NaOH were found to be quite effective to reveal the obliterated marks. These two procedures were also able to show effectively the marks obliterated by over-engraving and centre punching. Of the two techniques immersion in phosphoric acid provided more contrast. Interestingly, alternate swabbing of 60% HCl and 40% NaOH presented itself to be the common reagent for restoration on pure aluminium as well as its alloy surfaces. This is evident from our own current experiments and those of earlier researchers [G. Peeler, S. Gutowski, H. Wrobel, G. Dower, The restoration of impressed characters on aluminium alloy motor cycle frames, J. Forensic Ident. 58 (1) (2008) 27-32; M. Izhar M. Baharum, R. Kuppuswamy, A.A. Rahman, Restoration of engraved marks on aluminium surfaces by etching technique, Forensic Sci. Int. 177 (2008) 221-227]. The findings have assumed importance as engines and chassis of cars and frames of firearms are currently made of high strength aluminium alloys and recovery on these surfaces by current methods is not satisfactory.
    Matched MeSH terms: Engraving and Engravings
  2. Baharum MI, Kuppuswamy R, Rahman AA
    Forensic Sci Int, 2008 May 20;177(2-3):221-7.
    PMID: 18313246 DOI: 10.1016/j.forsciint.2008.01.004
    A study has been made of the characteristics of restoration of obliterated engraved marks on aluminium surfaces by etching technique. By etching different reagents on 0.61mm thick sheets of aluminium (99wt%) on which some engraved marks had been erased to different depths it was found that the reagent 60% hydrochloric acid and 40% sodium hydroxide on alternate swabbing on the surfaces was found to be the most sensitive one for these metal surfaces. This reagent was able to restore marks in the above plates erased down to 0.04mm below the bottom of the engraving. The marks also presented excellent contrast with the background. This reagent was further experimented with similar aluminium surfaces, but of relatively greater thickness of 1.5mm. It was noticed that the recovery depth increased slightly to 0.06mm; this suggested the dependence of recovery depth on the thickness of the sheet metal. Further, the depth of restoration decreased in cases where the original number was erased and over which a new number was engraved; the latter results are similar to those of steel surfaces reported earlier [M.A.M. Zaili, R. Kuppuswamy, H. Harun, Restoration of engraved marks on steel surfaces by etching technique, Forensic Sci. Int. 171 (2007) 27-32].
    Matched MeSH terms: Engraving and Engravings
  3. Aeinehvand MM, Weber L, Jiménez M, Palermo A, Bauer M, Loeffler FF, et al.
    Lab Chip, 2019 Feb 20.
    PMID: 30785443 DOI: 10.1039/c8lc00849c
    Reversible valves on centrifugal microfluidic platforms facilitate the automation of bioanalytical assays, especially of those requiring a series of steps (such as incubation) in a single reaction chamber. In this study, we present fixed elastic reversible (FER) valves and tunable elastic reversible (TER) valves that are easy to fabricate, implement and control. In the FER valve the compression of an elastic barrier/patch against a microchamber's outlet prevents the release of liquid. The valve sealing pressure was determined by adjusting the engraving depth of the valve-seat at which the elastic patch was located, this allows to set the sealing pressure during disc fabrication. In the TER valve, the patch compression value and sealing pressure is controlled by the penetration depth of a plastic screw into the valve-seat. The ER valves prevent liquid flow until the centrifugal force overcomes their sealing pressure. Moreover, at a constant spin speed, turning the screw of a TER valve reduces its sealing pressure and opens the valve. Therefore, the TER valve allows for controlling of the liquid transfer volume at various spin speeds. The FER and TER valves' behavior is mathematically described and equations for the prediction of their operation under centrifugal forces are provided. As a point-of-care (POC) application of ER valves, we have developed a microfluidic disc with a series of TER valves and peptide microarrays for automated multiplexed detection of five different proteins from a single serum sample.
    Matched MeSH terms: Engraving and Engravings
  4. Yin SH, Kuppuswamy R
    Forensic Sci Int, 2009 Jan 10;183(1-3):50-3.
    PMID: 19041202 DOI: 10.1016/j.forsciint.2008.10.009
    Chemical etching, which is the most sensitive method to recover obliterated serial numbers on metal surfaces, has been practised quite successfully in forensic science laboratories all over the world. A large number of etchants suitable for particular metal surfaces based on empirical studies is available in the literature. This article reviews the sensitivity and efficacy of some popular etchants for recovering obliterated marks on medium carbon steel (0.31% C with ferrite-pearlite microstructure) used in automobile parts. The experiments involved engraving these carbon steel plates with some alphanumeric characters using a computer controlled machine "Gravograph" and erasing them to several depths below the bottom of their engraving depth. Seven metallographic reagents of which most of them were copper containing compounds were chosen for etching. The erased plates were etched with every one of these etchants using swabbing method. The results have revealed that Fry's reagent comprising cupric chloride 90 g, hydrochloric acid 120 mL and water 100mL provided the necessary contrast and was concluded to be the most sensitive. The same reagent was recommended by earlier workers for revealing strain lines in steel surfaces. Earlier, another reagent containing 5 g copper sulphate, 60 mL water, 30 mL (conc.) ammonium hydroxide, and 60 mL (conc.) hydrochloric acid was proved to be more sensitive to restore erased marks on low carbon steel (0.1% C with ferrite-pearlite structure) [M.A.M. Zaili, R. Kuppuswamy, H. Harun, Restoration of engraved marks on steel surfaces by etching technique, Forensic Sci. Int. 171 (2007) 27-32]. Thus the sensitivity of the etching reagent on steel surfaces appeared to be dependent on the content of carbon in the steel.
    Matched MeSH terms: Engraving and Engravings
  5. Zaili MA, Kuppuswamy R, Harun H
    Forensic Sci Int, 2007 Aug 24;171(1):27-32.
    PMID: 17088038
    It is known that restoration of erased engraved identification marks on the engine and the chassis of a car or on a firearm has low success rate. Unlike stamping, engraving on a metal surface leaves no pronounced, permanent subsurface deformation in the crystalline structure, also called dislocation that can be revealed by suitable methods. Hence, the current research work investigated whether metallographic reagents used in the restoration of stamp (compression) marks could be applied to recover engraved marks on steel surfaces and also to establish the sensitivity and effectiveness of some of these reagents for the restoration of the marks. Experiments were conducted by mechanically engraving alphanumeric characters on several steel plates using a computer controlled engraving machine called Gravograph. The markings were later erased from the above steel plates by removing the metal in stages of 0.01 mm through 0.04 mm below the bottom of the engraving. Several plates were thus prepared wherein each one had been abraded to a specific depth. Then eight metallographic reagents were tested on each one of the above erased plates using a swabbing technique. The results had shown that while most of the reagents were able to restore marks up to certain levels of erasure, the reagent 5 g copper sulphate, 60 ml water, 30 ml concentrated ammonium hydroxide and 60 ml concentrated hydrochloric acid restored marks erased to a depth of 0.04 mm below the engraving depth, thus presenting itself the most sensitive reagent. Quite significantly, the above reagent was also able to decipher successfully the original engraved marks that had been erased and engraved with a new number, or obliterated by centre punching. The results of this research work should benefit the forensic practitioners engaged in the serial number recovery on vehicles, firearms and other objects.
    Matched MeSH terms: Engraving and Engravings