Affiliations 

  • 1 Faculty of Science & Technology, Kolej Universiti Sains & Teknologi Malaysia, Kuala Terengganu
Water Sci Technol, 2002;46(9):127-35.
PMID: 12448461

Abstract

The removal of natural organic matter (NOM) using a continuous flow fixed bed granular activated carbon (GAC) column was studied and the results were then fitted with the Adams-Bohart, Bed-Depth-Service-Time and Clarks models. The GAC, KI-6070 and KI-8085 used in the study had external surface areas of 277 m2/g and 547 m2/g, respectively. Adsorption of NOM by the GAC was complex and involved more than one rate-limiting step. The critical bed depths for KI-6070 and KI-8085 were 0.24 m and 0.3 m, respectively. The Clark model was more effective in simulating the absorbent breakthrough process as compared to the Adams-Bohart model. The lower empty bed contact time (EBCT) i.e. 15 minutes gave a better fit to the Clark Model as compared to EBCT of 20 and 30 minutes.