Affiliations 

  • 1 Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia; Perdana University-Royal College of Surgeons in Ireland, Serdang, Malaysia
  • 2 University of South Australia, Adelaide, Australia
  • 3 Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
  • 4 Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia. Electronic address: aganesan@gmail.com
J Am Coll Cardiol, 2015 Jun 23;65(24):2591-2600.
PMID: 25983009 DOI: 10.1016/j.jacc.2015.04.029

Abstract

BACKGROUND: Remote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent randomized controlled trial (RCT) and several large device database studies have demonstrated a powerful survival advantage for ICD patients undergoing RM compared with those receiving conventional in-office (IO) follow-up.

OBJECTIVES: This study sought to conduct a systematic published data review and meta-analysis of RCTs comparing RM with IO follow-up.

METHODS: Electronic databases and reference lists were searched for RCTs reporting clinical outcomes in ICD patients who did or did not undergo RM. Data were extracted from 9 RCTs, including 6,469 patients, 3,496 of whom were randomized to RM and 2,973 to IO follow-up.

RESULTS: In the RCT setting, RM demonstrated clinical outcomes comparable with office follow-up in terms of all-cause mortality (odds ratio [OR]: 0.83; p = 0.285), cardiovascular mortality (OR: 0.66; p = 0.103), and hospitalization (OR: 0.83; p = 0.196). However, a reduction in all-cause mortality was noted in the 3 trials using home monitoring (OR: 0.65; p = 0.021) with daily verification of transmission. Although the odds of receiving any ICD shock were similar in RM and IO patients (OR: 1.05; p = 0.86), the odds of inappropriate shock were reduced in RM patients (OR: 0.55; p = 0.002).

CONCLUSIONS: Meta-analysis of RCTs demonstrates that RM and IO follow-up showed comparable overall outcomes related to patient safety and survival, with a potential survival benefit in RCTs using daily transmission verification. RM benefits include more rapid clinical event detection and a reduction in inappropriate shocks.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.

Similar publications