  1. Jamaiyah H, Geeta A, Safiza MN, Khor GL, Wong NF, Kee CC, et al.
    Med J Malaysia, 2010 Jun;65 Suppl A:131-7.
    PMID: 21488474
    The National Health and Morbidity Survey III 2006 wanted to perform anthropometric measurements (length and weight) for children in their survey. However there is limited literature on the reliability, technical error of measurement (TEM) and validity of these two measurements. This study assessed the above properties of length (LT) and weight (WT) measurements in 130 children age below two years, from the Hospital Universiti Kebangsaan Malaysia (HUKM) paediatric outpatient clinics, during the period of December 2005 to January 2006. Two trained nurses measured WT using Tanita digital infant scale model 1583, Japan (0.01kg) and Seca beam scale, Germany (0.01 kg) and LT using Seca measuring mat, Germany (0.1cm) and Sensormedics stadiometer model 2130 (0.1cm). Findings showed high inter and intra-examiner reliability using 'change in the mean' and 'intraclass correlation' (ICC) for WT and LT. However, LT was found to be less reliable using the 'Bland and Altman plot'. This was also true using Relative TEMs, where the TEM value of LT was slightly more than the acceptable limit. The test instruments were highly valid for WT using 'change in the mean' and 'ICC' but was less valid for LT measurement. In spite of this we concluded that, WT and LT measurements in children below two years old using the test instruments were reliable and valid for a community survey such as NHMS III within the limits of their error. We recommend that LT measurements be given special attention to improve its reliability and validity.
    Study site: Paediatric clinic, Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM), Kuala Lumpur, Malaysia
  2. Jamaiyah H, Geeta A, Safiza MN, Wong NF, Kee CC, Ahmad AZ, et al.
    Malays J Nutr, 2008 Sep;14(2):137-50.
    PMID: 22691771 MyJurnal
    This study sought to examine the reliability of two measurements; Calf Circumference (CC) and Mid-half Arm Span (MHAS). A sample of 130 elderly persons aged 60 years and above seen consecutively in the Kuala Lumpur Hospital outpatient clinic during the period of December 2005 to January 2006, upon consent, were recruited to the study. There was a high degree of reliability for both inter- and intra-examiner (r close to 1). For inter-examiner, on average the CC measurements taken by the first examiner were 0.3 cm lower than that of the second examiner. The upper and lower limit of the differences were +0.4 to -0.9 cm respectively. Inter-examiner MHAS measurements on average by the first examiner were 0.2 cm lower than that of the second examiner. The limits were +1.7 to -2.1 cm. By comparison, the inter-examiner CC measurements were more reliable than the MHAS measurements. For intra-examiner, on average the CC measurements at Time 1 were consistent with Time 2 (mean difference=0) with limits of the difference at + 0.5 cm. MHAS measurements at Time 1 were on average 0.1 cm less than at Time 2 with limits at +1.7 and -1.8 cm. The technical error of measurement (TEM) and coefficient of variation of CC and MHAS for both interexaminer and intra-examiner measurements were within acceptable limits with the exception of MHAS TEM. This study suggests that CC and MHAS measured in elderly persons 60 years and above, using Seca Circumference Tape ® 206, Germany (0.05 cm) are reliable and can be used in a community survey.

    Study site: Outpatient clinic, Hospital Kuala Lumpur