Displaying all 5 publications

Abstract:
Sort:
  1. Saleh S, Jamaluddin MH, Razzaz F, Saeed SM
    Micromachines (Basel), 2022 Nov 18;13(11).
    PMID: 36422442 DOI: 10.3390/mi13112013
    In this study, at two different fifth generation (5G) low-frequency bands (3.7-4.2 GHz and 5.975-7.125 GHz) and based on nonuniform transmission lines (NTLs) theory, a compact three-quarter-wave resonators interdigital bandpass filter (IBPF) is analyzed, designed, and fabricated. The compact proposed filter is considered as a good candidate for reconfigurable 5G low-frequency bands and ultrawide band (UWB) antenna, which will reduce the size of the final RF communication system. Firstly, a uniform transmission line (UTL) IBPF at these two bands is designed and tested; then the NTL concept is applied for compactness. For both UTL and NTL IBPFs, different parametric studies are performed for optimization. At the first frequency band, size reductions of 16.88% and 16.83% are achieved in the first (symmetrical to the third resonator) and second λ/4 resonator of UTL IBPF, respectively, with up to 36.6% reduction in the total area. However, 16.46% and 16.33% size reductions are obtained in the first (symmetrical to the third resonator) and second λ/4 resonator, respectively, at the second frequency band with a 40.53% reduction in the whole circuit area. The performance of the proposed NTL IBPF is compared with the UTL IBPF. The measured reflection coefficient of the proposed NTL IBPF, S11, appears to be less than -10.53 dB and -11.27 dB through 3.7-4.25 GHz and 5.94-7.67 GHz, respectively. However, the transmission coefficient, S12 is around -0.86 dB and-1.7 dB at the center frequencies, fc = 3.98 GHz and 6.81 GHz, respectively. In this study, simulations are carried out using high-frequency structure simulator (HFSS) software based on the finite element method (FEM). The validity of the proposed theoretical schematic of this filter is proved by design simulations and measured results of its prototype.
  2. Saleh S, Ahmad K, Mohd Yunus NZ, Hezmi MA
    Environ Sci Pollut Res Int, 2020 Jun;27(17):21252-21259.
    PMID: 32266626 DOI: 10.1007/s11356-020-08549-y
    In civil engineering, many geotechnical and forensic projects employ polyurethane (PU) for ground improvement, and the results have shown to be effective in terms of time and cost savings. However, similar to many other chemical stabilisers, the use of PU for soil stabilisation may have environmental repercussions. Therefore, this paper utilised a toxicity characteristic leaching procedure (TCLP) to investigate the potential for ground contamination resulting from the application of PU for the stabilisation of marine clay. Furthermore, the hazardousness of PU during the stabilisation of marine clay was investigated by testing its reactivity, ignitability, corrosivity and physical properties. The results reveal that the quantity of heavy metals present in PU is far below the regulatory limits. The results further confirm that PU is odourless and non-corrosive and that it is non-cyanide and non-sulphide-bearing. However, PU is capable of igniting. Overall, the potential application of PU for ground improvement is promising due to its environmental friendliness.
  3. Abbasi MS, Ahmed N, Irfan AB, Al-Saleh S, Abduljabbar T, Vohra F
    Case Rep Dent, 2022;2022:2686983.
    PMID: 35154831 DOI: 10.1155/2022/2686983
    Microstomia is an abnormally reduced oral aperture. In the literature, it is not classified by any particular size criteria, rather defined by its effects on function and esthetics. Prosthodontic management of edentulous patients with microstomia is a challenging task. Use of conventional methods for recording an impression and fabricating prosthesis is not effective in such patients. To fabricate well-fitting prosthesis, accuracy of impression recording important anatomic landmarks is essential. Formation of an exacting custom tray and diagnostic cast is critical for final impression accuracy. Provision of a well-fitting prosthesis in microstomia patient will restore esthetics, comfort, and function with oral and systemic patient wellbeing. This paper presents a case report of managing an edentulous microstomia patient with sectional removable prosthesis. Furthermore, it proposes a novel classification system for microstomia patients according to severity of the condition.
  4. Saeidi T, Saleh S, Mahmood SN, Timmons N, Al-Gburi AJA, Karamzadeh S, et al.
    Heliyon, 2024 Jun 30;10(12):e33024.
    PMID: 38994104 DOI: 10.1016/j.heliyon.2024.e33024
    A miniaturized, multi-band, four-port wearable Multiple Input Multiple Output (MIMO) antenna is proposed, which contains a leaky wave textile antenna (LWTA) on denim (εr = 1.6, tanδ = 0.006) as substrate and Shieldit Super Fabric as conductor textile. The concept in this work involves incorporating the metal and plastic zipper into the garment to function as an antenna worn on the body. Simulations and measurements have been conducted to explore this idea. The LWTA has dimensions of 40 × 30 × 1 mm³. Every two ports are separated by a zipper with two different kinds of materials: Acetal Polymer Plastic (APP) and 90 % brass to improve the isolation, gain, and Impedance bandwidth. The antenna operates in the frequency ranges covering the L, C, S, and X bands. Additionally, diversity performance is evaluated using the Envelope Correlation Coefficient (ECC) and diversity gain (DG). Simulation and measurement findings agree well, with a maximum gain of 12.15 dBi, low Specific Absorption Rate (SAR) based on the standards, DG greater than 9.65 dB, circular polarization (CP), and strong isolation (
  5. Ahmed N, Khalid S, Vohra F, Halim MS, Al-Saleh S, Tulbah HI, et al.
    J Prosthet Dent, 2024 Feb;131(2):187-196.
    PMID: 35277267 DOI: 10.1016/j.prosdent.2021.11.035
    STATEMENT OF PROBLEM: The recurrent esthetic dental (RED) proportion has been a benchmark for the rehabilitation of the maxillary anterior teeth of North American patients. While it has been evaluated in other populations, the global application of RED proportions in the rehabilitation of maxillary anterior teeth is unclear.

    PURPOSE: The purpose of this systematic review was to examine the existing evidence on dental proportion to evaluate the existence of RED proportions in the esthetic smile in different geographic regions.

    MATERIAL AND METHODS: A systematic search was conducted by reviewing different databases. The focused question was "Does RED proportion exist in esthetically pleasing smiles in different populations around the world?" The search included articles with a combination of MeSH keywords based on dental proportion from January 2000 to July 2020. The titles and abstracts were identified by using a search protocol. Full text of the articles was independently evaluated. The systematic review was modified to summarize the relevant data. The general characteristics, outcomes, and quality of studies were reviewed and analyzed systematically.

    RESULTS: Seventeen studies were selected from the reviewed articles. Three studies were conducted in Europe, 10 in South Asia, and 4 in Western Asia. Eleven studies found that the mean perceived ratio of anterior teeth was not constant when progressing distally. Five studies reported that the ratio was constant in a small percentage of their populations, and 1 suggested that the ratio was constant if it remains between 60% and 80%. The central-to-LI and Ca-to-LI proportion values were not constant. Overall, the Ca-to-LI proportion values were higher than the central-to-LI proportions.

    CONCLUSIONS: RED proportions were not found in the successive widths of maxillary anterior teeth among the reviewed data from different geographic regions. RED proportions are not the only standard for restoring esthetic smiles worldwide, and anterior tooth proportions differ among populations based on their race and ethnicity.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links