Displaying all 6 publications

Abstract:
Sort:
  1. Kumaraguru P, Mazri YM, Yaacob AF, Hanif H, Zainal AA, Lau JH
    Med J Malaysia, 2011 Oct;66(4):381-2.
    PMID: 22299568 MyJurnal
    Conventional open repair for Thoracoabdominal aortic aneurysm (TAA) is associated with high morbidity and mortality. Spinal cord ischemia (SCI), renal failure, bowel ischemia and mortality are established complications following this procedure. With the advent of endovascular stent technology, various novel approaches have been described to reduce these complications, namely fenestrated stent graft and hybrid procedure. We present a case of hybrid procedure in a pseudoaneurysm of descending thoracic aorta done in Kuala Lumpur Hospital.
    Matched MeSH terms: Aortic Aneurysm, Thoracic/surgery*
  2. Harunarashid H, Jasman WJ, Azim MM, Das S
    Clin Ter, 2012 Jul;163(4):311-2.
    PMID: 23007815
    Mycotic descending thoracic aneurysm with aortobronchial fistula is a rare condition which is associated with high mortality. Treatment in the era of minimally invasive procedure can often be controversial. The risk of graft infection should be considered as well as the unknown long term behavior of the endovascular stent. Here, we describe our initial experience of performing emergency thoracic endovascular aneurysm repair in an unstable patient presenting with haemoptysis.
    Matched MeSH terms: Aortic Aneurysm, Thoracic/surgery*
  3. Eng JB
    Med J Malaysia, 2007 Jun;62(2):177-8.
    PMID: 18705461 MyJurnal
    A 58 year-old man presented with a large aneurysm of the aortic arch and severe coronary artery disease. He underwent combined repair of the aortic arch aneurysm and coronary artery bypass grafting via a modified clamshell incision using deep hypothermic circulatory arrest and retrograde cerebral perfusion. He made an uncomplicated postoperative recovery. The operative techniques are discussed with a review of the relevant literature.
    Matched MeSH terms: Aortic Aneurysm, Thoracic/surgery*
  4. Wan Ab Naim WN, Ganesan PB, Sun Z, Lei J, Jansen S, Hashim SA, et al.
    Int J Numer Method Biomed Eng, 2018 05;34(5):e2961.
    PMID: 29331052 DOI: 10.1002/cnm.2961
    Endovascular stent graft repair has become a common treatment for complicated Stanford type B aortic dissection to restore true lumen flow and induce false lumen thrombosis. Using computational fluid dynamics, this study reports the differences in flow patterns and wall shear stress distribution in complicated Stanford type B aortic dissection patients after endovascular stent graft repair. Five patients were included in this study: 2 have more than 80% false lumen thrombosis (group 1), while 3 others had less than 80% false lumen thrombosis (group 2) within 1 year following endovascular repair. Group 1 patients had concentrated re-entry tears around the abdominal branches only, while group 2 patients had re-entry tears that spread along the dissection line. Blood flow inside the false lumen which affected thrombus formation increased with the number of re-entry tears and when only small amounts of blood that entered the false lumen exited through the branches. In those cases where dissection extended below the abdominal branches (group 2), patients with fewer re-entry tears and longer distance between the tears had low wall shear stress contributing to thrombosis. This work provides an insight into predicting the development of complete or incomplete false lumen thrombosis and has implications for patient selection for treatment.
    Matched MeSH terms: Aortic Aneurysm, Thoracic/surgery*
  5. Sia KJ, Ashok GD, Ahmad FM, Kong CK
    Hong Kong Med J, 2013 Dec;19(6):542-4.
    PMID: 24310662 DOI: 10.12809/hkmj133668
    We describe a rare case of aorto-oesophageal fistula and aortic pseudoaneurysm in a middle-aged man, who presented with chest pain and haematemesis 1 week after swallowing a fish bone. Oesophagogastroduodenoscopy and computed tomographic angiography findings were consistent with oesophageal perforation, proximal descending aortic pseudoaneurysm, and aorto-oesophageal fistula. Thoracic endovascular aortic repair was performed. The patient died from severe mediastinal sepsis. Early surgical intervention and broad-spectrum antibiotic therapy are crucial in preventing life-threatening mediastinal infection.
    Matched MeSH terms: Aortic Aneurysm, Thoracic/surgery
  6. Zubaidah NH, Azim MI, Osama MH, Harunarashid H, Das S
    Clin Ter, 2012;163(1):27-9.
    PMID: 22362230
    The incidence of infection following TEVAR is low. To the best of our knowledge, this is the first case report of post thoracic endovascular aortic repair (TEVAR) with Streptococcus viridans graft infection. A 54-year-old male underwent TEVAR for dissecting thoracic aneurysm with spinal ischaemia. He had an eventful recovery with prolonged period of stay in intensive care unit. Three months later, he presented with persistent chest discomfort and fever. Computed tomography (CT) of the thorax revealed evidence of graft infection and the blood culture grew Streptococcus viridans. The rarity of TEVAR graft infection due to Streptococcus viridans and its management are being discussed.
    Matched MeSH terms: Aortic Aneurysm, Thoracic/surgery*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links