Displaying publications 1 - 20 of 24 in total

Abstract:
Sort:
  1. Zuhdi AS, Mariapun J, Mohd Hairi NN, Wan Ahmad WA, Abidin IZ, Undok AW, et al.
    Ann Saudi Med, 2014 1 15;33(6):572-8.
    PMID: 24413861 DOI: 10.5144/0256-4947.2013.572
    BACKGROUND AND OBJECTIVES: Understanding the nature and pattern of young coronary artery disease (CAD) is important due to the tremendous impact on these patients' socio-economic and physical aspect. Data on young CAD in the southeast Asian region is rather patchy and limited. Hence we utilized our National Cardiovascular Disease Database (NCVD)-Percutaneous Coronary Intervention (PCI) Registry to analyze young patients who underwent PCI in the year 2007 to 2009.

    DESIGN AND SETTINGS: This is a retrospective study of all patients who had undergone coronary angioplasty from 2007 to 2009 in 11 hospitals across Malaysia.

    METHODS: Data were obtained from the NCVD-PCI Registry, 2007 to 2009. Patients were categorized into 2 groups-young and old, where young was defined as less than 45 years for men and less than 55 years for women and old was defined as more than or equals to 45 years for men and more than or equals to 55 years for women. Patients' baseline characteristics, risk factor profile, extent of coronary disease and outcome on dis.charge, and 30-day and 1-year follow-up were compared between the 2 groups.

    RESULTS: We analyzed 10268 patients, and the prevalence of young CAD was 16% (1595 patients). There was a significantly low prevalence of Chinese patients compared to other major ethnic groups. Active smoking (30.2% vs 17.7%) and obesity (20.9% vs 17.3%) were the 2 risk factors more associated with young CAD. There is a preponderance toward single vessel disease in the young CAD group, and they had a favorable clinical outcome in terms of all-cause mortality at discharge (RR 0.49 [CI 0.26-0.94]) and 1-year follow-up (RR 0.47 [CI 0.19-1.15]).

    CONCLUSION: We observed distinctive features of young CAD that would serve as a framework in the primary and secondary prevention of the early onset CAD.

    Matched MeSH terms: Coronary Artery Disease/therapy*
  2. Park SJ, Ahn JM, Kim YH, Park DW, Yun SC, Lee JY, et al.
    N Engl J Med, 2015 Mar 26;372(13):1204-12.
    PMID: 25774645 DOI: 10.1056/NEJMoa1415447
    BACKGROUND: Most trials comparing percutaneous coronary intervention (PCI) with coronary-artery bypass grafting (CABG) have not made use of second-generation drug-eluting stents.
    METHODS: We conducted a randomized noninferiority trial at 27 centers in East Asia. We planned to randomly assign 1776 patients with multivessel coronary artery disease to PCI with everolimus-eluting stents or to CABG. The primary end point was a composite of death, myocardial infarction, or target-vessel revascularization at 2 years after randomization. Event rates during longer-term follow-up were also compared between groups.
    RESULTS: After the enrollment of 880 patients (438 patients randomly assigned to the PCI group and 442 randomly assigned to the CABG group), the study was terminated early owing to slow enrollment. At 2 years, the primary end point had occurred in 11.0% of the patients in the PCI group and in 7.9% of those in the CABG group (absolute risk difference, 3.1 percentage points; 95% confidence interval [CI], -0.8 to 6.9; P=0.32 for noninferiority). At longer-term follow-up (median, 4.6 years), the primary end point had occurred in 15.3% of the patients in the PCI group and in 10.6% of those in the CABG group (hazard ratio, 1.47; 95% CI, 1.01 to 2.13; P=0.04). No significant differences were seen between the two groups in the occurrence of a composite safety end point of death, myocardial infarction, or stroke. However, the rates of any repeat revascularization and spontaneous myocardial infarction were significantly higher after PCI than after CABG.
    CONCLUSIONS: Among patients with multivessel coronary artery disease, the rate of major adverse cardiovascular events was higher among those who had undergone PCI with the use of everolimus-eluting stents than among those who had undergone CABG. (Funded by CardioVascular Research Foundation and others; BEST ClinicalTrials.gov number, NCT00997828.).
    Matched MeSH terms: Coronary Artery Disease/therapy*
  3. Leschke M, Waliszewski M, Pons M, Champin S, Nait Saidi L, Mok Heang T, et al.
    Catheter Cardiovasc Interv, 2016 Sep;88(3):358-66.
    PMID: 26650913 DOI: 10.1002/ccd.26261
    OBJECTIVES: This observational study assessed the 9-month clinical outcomes in an « all comers » population with a focus on patients with atrial fibrillation (AF) after thin strut bare metal stenting.

    BACKGROUND: Drug eluting stent (DES) implantation is the treatment of choice for coronary artery disease (CAD) leaving only marginal indications for the use of bare metal stents (BMS). However, selected treatment populations with DES contraindications such as patients who cannot sustain 6-12 months of dual antiplatelet therapy (DAPT) remain candidates for BMS implantations.

    METHODS: Thin strut bare metal stenting in a priori defined subgroups were investigated in a non-randomized, international, multicenter «all comers» observational study. Primary endpoint was the 9-month TLR rate whereas secondary endpoints included the 9-month MACE and procedural success rates.

    RESULTS: A total of 783 patients of whom 98 patients had AF underwent BMS implantation. Patient age was 70.4 ± 12.8 years. Cardiovascular risk factors in the overall population were male gender (78.2%, 612/783), diabetes (25.2%, 197/783), hypertension (64.1%, 502/783), cardiogenic shock (4.9%, 38/783) and end stage renal disease (4.9%, 38/783). In-hospital MACE was 4.1% (30/783) in the overall population. The 9-month TLR rate was 4.5% (29/645) in the non-AF group and 3.3% (3/90) in the AF group (P = 0.613). At 9 months, the MACE rate in the AF-group and non-AF group was not significantly different either (10.7%, 69/645 vs. 6.7%, 6/90; P = 0.237). Accumulated stroke rates were 0.3% (2/645) in the non-AF subgroup at baseline and 1.1% (1/90) in the AF subgroup (P = 0.264).

    CONCLUSION: Bare metal stenting in AF patients delivered acceptably low TLR and MACE rates while having the benefit of a significantly shorter DAPT duration in a DES dominated clinical practice. © 2015 Wiley Periodicals, Inc.

    Matched MeSH terms: Coronary Artery Disease/therapy*
  4. Liew HB, Rosli MA, Wan Azman WA, Robaayah Z, Sim KH, NCVD PCI investigators
    Med J Malaysia, 2008 Sep;63 Suppl C:41-4.
    PMID: 19230246
    The National Cardiovascular Database for Percutaneous Coronary Intervention (NCVD PCI) Registry is the first multicentre interventional cardiology project, involving the main cardiac centres in the country. The ultimate goal of NCVD PCI is to provide a contemporary appraisal of PCI in Malaysia. This article introduces the foundation, the aims, methodology, database collection and preliminary results of the first six-month database.
    Matched MeSH terms: Coronary Artery Disease/therapy*
  5. Haude M, Lee SWL, Worthley SG, Silber S, Verheye S, Rosli MA, et al.
    Catheter Cardiovasc Interv, 2020 05 01;95(6):1076-1084.
    PMID: 31489742 DOI: 10.1002/ccd.28483
    OBJECTIVES: To evaluate the long-term safety and efficacy of the novel combined sirolimus-eluting endothelial progenitor cell capture Combo stent (OrbusNeich, Fort Lauderdale, FL) at 5 years in the REMEDEE (Randomized study to Evaluate the safety and effectiveness of an abluMinal sirolimus coated bio-Engineered stEnt) trial.

    BACKGROUND: Drug-eluting stents have limited restenosis and reintervention but are complicated by late and very late thrombosis and accelerated neoatherosclerosis. Alternative or adjunctive technologies are needed to address these limitations.

    METHODS: A total of 183 patients with de novo lesions in native coronary arteries were randomized 2:1 to Combo (n = 124) or Taxus Liberté (n = 59). Primary endpoint was 9 month angiographic in-stent late lumen loss and the secondary endpoint was the occurrence of major adverse events (MACE) through 5-year follow-up.

    RESULTS: Compared with Taxus, after 5 years the Combo stent was associated with similar rates of MACE (18.3% vs. 16.9%, p = .89), cardiac death (0.8% vs. 5.1%, p = .07), myocardial infarction (4.1% vs. 3.4%, p = .81), target lesion (9.4% vs. 10.2%, p = .78), and target vessel revascularization (14.4% vs. 11.9%, p = .73). No cases of definite stent thrombosis were reported in the Combo group. The follow-up rate at 5 years was 97.7%.

    CONCLUSION: At 5-year follow-up, the Combo stent remained clinically safe and effective with an overall low rate of MACE comparable to Taxus.

    Matched MeSH terms: Coronary Artery Disease/therapy*
  6. Lee WL, Chinna K, Bulgiba A, Abdullah KL, Abidin IZ, Höfer S
    Qual Life Res, 2016 Feb;25(2):351-357.
    PMID: 26254801 DOI: 10.1007/s11136-015-1097-1
    OBJECTIVES: Heart Quality of Life (HeartQoL) is a new "hybrid" developed from the MacNew and two condition-specific questionnaires measuring health-related quality of life (HRQoL) in patients with ischemic heart disease (IHD). This study investigates test-retest reliability of HeartQoL (English version) according to international criteria (e.g., COSMIN, GRRAS). Findings on HeartQoL are compared to the published data on MacNew in view that both serve as the core IHD-specific HRQoL instrument.

    METHODS: Out of 105 patients with IHD, 76 completed self-administration of HeartQoL at the clinic followed by at home within a 2-week interval. In retest, patients responded using non-interview methods (phone messaging, email, fax, and post). Phone interviewing was reserved for non-respondents to reminder.

    RESULTS: Reliability of HeartQoL was good (intraclass correlation coefficients = 0.78-0.82), was supported in the Bland-Altman plot, and was comparable to five studies on MacNew of similar retest interval (MacNew-English = 0.70-0.75; translated MacNew = 0.72-0.91). Applicability of its standard error of measurement (0.20-0.25) and smallest detectable change (0.55-0.70) will depend on availability of normative data in future.

    CONCLUSION: The reliability of HeartQoL is comparable to its parent instrument, the MacNew. The HeartQoL is a potentially reliable core IHD-specific HRQoL instrument in measuring group change.

    Matched MeSH terms: Coronary Artery Disease/therapy
  7. Montefusco A, D'Ascenzo F, Gili S, Smolka G, Chieffo A, Baumbach A, et al.
    Catheter Cardiovasc Interv, 2019 02 01;93(2):208-215.
    PMID: 30298593 DOI: 10.1002/ccd.27809
    OBJECTIVES: To compare the effectiveness and safety of self-expandable, sirolimus-eluting Stentys stents (SES) and second-generation drug-eluting stents (DES-II) for the treatment of the unprotected left main (ULM).

    BACKGROUND: SES may provide a valuable option to treat distal ULM, particularly when significant caliber gaps with side branches are observed.

    METHODS: Patients from the multicenter SPARTA (clinicaltrials.gov: NCT02784405) and FAILS2 registries were included. Propensity-score with matching was performed to account for the lack of randomization. Primary end-point was the rate of major adverse cardiovascular events (MACE, a composite of all cause death, myocardial infarction, target lesion revascularization [TLR], unstable angina and definite stent thrombosis [ST]). Single components of MACE were the secondary end-points.

    RESULTS: Overall, 151 patients treated with SES and 1270 with DES-II were included; no differences in MACE rate at 250 days were observed (9.8% vs. 11.5%, P = 0.54). After propensity score with matching, 129 patients treated with SES and 258 with DES-II, of which about a third of female gender, were compared. After a follow-up of 250 days, MACE rate did not differ between the two groups (9.9% vs. 8.5%, P = 0.66), as well as the rate of ULM TLR (1.6% vs. 3.1%, P = 0.36) and definite ST (0.8% vs. 1.2%, P = 0.78). These results were consistent also when controlling for the treatment with provisional vs. 2-stents strategies for the ULM bifurcation.

    CONCLUSION: SES use for ULM treatment was associated with a similar MACE rate compared to DES-II at an intermediate-term follow-up. SES might represent a potential option in this setting.

    Matched MeSH terms: Coronary Artery Disease/therapy*
  8. Krackhardt F, Waliszewski M, Kočka V, Toušek P, Janek B, Hudec M, et al.
    Cardiovasc Drugs Ther, 2020 06;34(3):335-344.
    PMID: 32212061 DOI: 10.1007/s10557-020-06963-5
    OBJECTIVES: The objective of this post hoc analysis was to analyze real-world dual antiplatelet therapy (DAPT) regimens following polymer-free sirolimus-eluting stent (PF-SES) implantations in an unselected patient population.

    METHODS: Patient-level data from two all-comers observational studies (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled and analyzed in terms of their primary endpoint. During the data verification process, we observed substantial deviations from DAPT guideline recommendations. To illuminate this gap between clinical practice and guideline recommendations, we conducted a post hoc analysis of DAPT regimens and clinical event rates for which we defined the net adverse event rate (NACE) consisting of target lesion revascularization (TLR, primary endpoint of all-comers observational studies) all-cause death, myocardial infarction (MI), stent thrombosis (ST), and bleeding events. A logistic regression was utilized to determine predictors why ticagrelor was used in stable coronary artery disease (CAD) patients instead of the guideline-recommended clopidogrel.

    RESULTS: For stable CAD, the composite endpoint of clinical, bleeding, and stent thrombosis, i.e., NACE, between the clopidogrel and ticagrelor treatment groups was not different (5.4% vs. 5.1%, p = 0.745). Likewise, in the acute coronary syndrome (ACS) cohort, the NACE rates were not different between both DAPT strategies (9.2% vs. 9.3%, p = 0.927). There were also no differences in the accumulated rates for TLR, myocardial infarction ([MI], mortality, bleeding events, and stent thrombosis in elective and ACS patients. The main predictors for ticagrelor use in stable CAD patients were age

    Matched MeSH terms: Coronary Artery Disease/therapy*
  9. Rosenberg M, Waliszewski M, Chin K, Ahmad WAW, Caramanno G, Milazzo D, et al.
    Catheter Cardiovasc Interv, 2019 02 01;93(2):181-188.
    PMID: 30280482 DOI: 10.1002/ccd.27724
    OBJECTIVES: This prospective, observational all-comers registry assessed the safety and efficacy of a Drug Coated Balloon-only strategy (DCB-only) in patients with coronary lesions.

    BACKGROUND: Data regarding the performance of a DCB-only approach, especially in patients with previously untreated de-novo coronary artery disease (CAD), are still limited.

    METHODS: This study was conducted as an international, multicenter registry primarily enrolling patients with de-novo CAD. However, it was also possible to include patients with in-stent restenosis (ISR). The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) after 9 months.

    RESULTS: A total of 1,025 patients with a mean age of 64.0 ± 11.2 years were enrolled. The majority of treated lesions were de-novo (66.9%), followed by drug-eluting-stent ISR (DES-ISR; 22.6%) and bare-metal-stent ISR (BMS-ISR; 10.5%). The TLR rate was lower in the de-novo group (2.3%) when compared to BMS- (2.9%) and DES-ISR (5.8%) (P = 0.049). Regarding MACE, there was a trend toward fewer events in the de-novo group (5.6%) than in the BMS- (7.8%) and DES-ISR cohort (9.6%) (P = 0.131). Subgroup analyses revealed that lesion type (95% CI 1.127-6.587); P = 0.026) and additional stent implantation (95% CI 0.054-0.464; P = 0.001) were associated with higher TLR rates.

    CONCLUSIONS: Our results show that DCB-only angioplasty of de-novo coronary lesions is associated with low MACE and TLR rates. Thus, DCBs appear to be an attractive alternative for the interventional, stentless treatment of suitable de-novo coronary lesions.

    Matched MeSH terms: Coronary Artery Disease/therapy*
  10. Urban P, Meredith IT, Abizaid A, Pocock SJ, Carrié D, Naber C, et al.
    N Engl J Med, 2015 Nov 19;373(21):2038-47.
    PMID: 26466021 DOI: 10.1056/NEJMoa1503943
    BACKGROUND: Patients at high risk for bleeding who undergo percutaneous coronary intervention (PCI) often receive bare-metal stents followed by 1 month of dual antiplatelet therapy. We studied a polymer-free and carrier-free drug-coated stent that transfers umirolimus (also known as biolimus A9), a highly lipophilic sirolimus analogue, into the vessel wall over a period of 1 month.
    METHODS: In a randomized, double-blind trial, we compared the drug-coated stent with a very similar bare-metal stent in patients with a high risk of bleeding who underwent PCI. All patients received 1 month of dual antiplatelet therapy. The primary safety end point, tested for both noninferiority and superiority, was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy end point was clinically driven target-lesion revascularization.
    RESULTS: We enrolled 2466 patients. At 390 days, the primary safety end point had occurred in 112 patients (9.4%) in the drug-coated-stent group and in 154 patients (12.9%) in the bare-metal-stent group (risk difference, -3.6 percentage points; 95% confidence interval [CI], -6.1 to -1.0; hazard ratio, 0.71; 95% CI, 0.56 to 0.91; P<0.001 for noninferiority and P=0.005 for superiority). During the same time period, clinically driven target-lesion revascularization was needed in 59 patients (5.1%) in the drug-coated-stent group and in 113 patients (9.8%) in the bare-metal-stent group (risk difference, -4.8 percentage points; 95% CI, -6.9 to -2.6; hazard ratio, 0.50; 95% CI, 0.37 to 0.69; P<0.001).
    CONCLUSIONS: Among patients at high risk for bleeding who underwent PCI, a polymer-free umirolimus-coated stent was superior to a bare-metal stent with respect to the primary safety and efficacy end points when used with a 1-month course of dual antiplatelet therapy. (Funded by Biosensors Europe; LEADERS FREE ClinicalTrials.gov number, NCT01623180.).
    Matched MeSH terms: Coronary Artery Disease/therapy*
  11. Windecker S, Latib A, Kedhi E, Kirtane AJ, Kandzari DE, Mehran R, et al.
    N Engl J Med, 2020 03 26;382(13):1208-1218.
    PMID: 32050061 DOI: 10.1056/NEJMoa1910021
    BACKGROUND: Polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited.

    METHODS: In an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority.

    RESULTS: A total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority).

    CONCLUSIONS: Among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.).

    Matched MeSH terms: Coronary Artery Disease/therapy*
  12. Amin AM, Sheau Chin L, Teh CH, Mostafa H, Mohamed Noor DA, Abdul Kader MASK, et al.
    Eur J Pharm Sci, 2018 May 30;117:351-361.
    PMID: 29526765 DOI: 10.1016/j.ejps.2018.03.011
    Dual antiplatelet therapy (DAPT) of clopidogrel and aspirin is crucial for coronary artery disease (CAD) patients undergoing percutaneous coronary intervention (PCI). However, some patients may endure clopidogrel high on treatment platelets reactivity (HTPR) which may cause thromboembolic events. Clopidogrel HTPR is multifactorial with some genetic and non-genetic factors contributing to it. We aimed to use nuclear magnetic resonance (1H NMR) pharmacometabolomics analysis of plasma to investigate this multifactorial and identify metabolic phenotypes and pathways associated with clopidogrel HTPR. Blood samples were collected from 71 CAD patients planned for interventional angiographic procedure (IAP) before the administration of clopidogrel 600 mg loading dose (LD) and 6 h after the LD. Platelets function testing was done 6 h post-LD using VerifyNow® P2Y12 assay. Pre-dose and post-dose plasma samples were analysed using 1H NMR. Multivariate statistical analysis was used to indicate the discriminating metabolites. Two metabotypes, each with 34 metabolites (pre-dose and post-dose) were associated with clopidogrel HTPR. Pathway analysis of these metabotypes revealed that aminoacyl-tRNA biosynthesis, nitrogen metabolism and glycine-serine-threonine metabolism are the most perturbed metabolic pathways associated with clopidogrel HTPR. Furthermore, the identified biomarkers indicated that clopidogrel HTPR is multifactorial where the metabolic phenotypes of insulin resistance, type two diabetes mellitus, obesity, gut-microbiota and heart failure are associated with it. Pharmacometabolomics analysis of plasma revealed new insights on the implicated metabolic pathways and the predisposing factors of clopidogrel HTPR.
    Matched MeSH terms: Coronary Artery Disease/therapy*
  13. Sadiq MA, Azman W, Abidin IZ
    J Invasive Cardiol, 2012 Jan;24(1):E13-5.
    PMID: 22210591
    Permanent complete heart block (CHB) secondary to the loss of first septal perforator after percutaneous coronary intervention (PCI) of the left descending artery (LAD) is an extremely rare complication. We describe a case report where a patient underwent PCI of proximal LAD, complicated by loss of first septal perforator, septal infarction, and bifasicular block, which progressed to symptomatic delayed CHB. One week later, the patient required implantation of a permanent pacemaker following failure to wean off the transvenous temporary pacing maker.
    Matched MeSH terms: Coronary Artery Disease/therapy*
  14. Kaur S, Zainal NZ, Low WY, Ramasamy R, Sidhu JS
    Asia Pac J Public Health, 2015 May;27(4):450-60.
    PMID: 24807887 DOI: 10.1177/1010539514533719
    The Hospital Anxiety and Depression Scale (HADS) is a common screening instrument used to determine the levels of anxiety and depression experienced by a patient and has been extensively used in patients with coronary artery disease (CAD). This study aimed to establish the factor structure of HADS in a Malaysian sample of 189 patients with CAD. Factor analysis of HADS using principal component analysis with varimax rotation yielded 3 factors. Confirmatory factor analysis supported the use of HADS in assessing 3 distinct dimensions of psychological distress--namely, anxiety, anhedonia, and psychomotor retardation. The HADS showed good internal consistency and was found to be a valid measure of psychological distress among Malaysian patients with CAD. However, low mean scores on the original 2 factors--that is, anxiety and depression--and also on the 2 depression subscales--anhedonia and psychomotor retardation--suggests that the recommended cutoff score to screen for psychological distress among CAD patients be reevaluated. Further research to determine the generalizability and consistency for the tridimensional structure of the HADS in Malaysia is recommended.
    Matched MeSH terms: Coronary Artery Disease/therapy
  15. Kaul U, Patel TM, Zambahari R, Mullasari AS, Bahl VK, Stuteville M, et al.
    Indian Heart J, 2011 Sep-Oct;63(5):402-8.
    PMID: 23550416
    Asian patients have a uniquely high risk for heart disease compared to other ethnicities. Past drug eluting stent trials have examined mainly populations of European heritage. As a significant proportion of the real world population in the SPIRIT V single arm study is Asian, the study provides insight into how this population responds to stenting with the XIENCE V Everolimus Eluting Coronary Stent (EES).
    Matched MeSH terms: Coronary Artery Disease/therapy*
  16. Biswas M, Rahaman S, Biswas TK, Ibrahim B
    Expert Opin Drug Saf, 2020 Dec;19(12):1605-1616.
    PMID: 33040624 DOI: 10.1080/14740338.2020.1836152
    INTRODUCTION: The effects of the ABCB1 C3435T genetic polymorphism on clopidogrel responses are conflicting and inconclusive especially in patients undergoing percutaneous coronary intervention (PCI). This study examined the pooled risk of major adverse cardiovascular events (MACE) and bleeding events associated with the ABCB1 C3435T polymorphism in acute coronary syndrome or coronary artery disease patients undergoing PCI and treated with clopidogrel.

    AREAS COVERED: Literature was searched in different resources for eligible studies. The pooled risk ratio was measured using RevMan software, with p<0.05 (two-sided) set as statistically significant.

    EXPERT OPINION: The ABCB1 C3435T homozygous mutant (TT) was associated with significantly increased risk of MACE compared to either wild type genotype (CC) or the combination of wild type and heterozygous genotypes (TT vs. CC: RR 1.33; 95% CI 1.06-1.68; p=0.02; TT vs. CC+CT: RR 1.32; 95% CI 1.10-1.60; p=0.004). Safety outcomes, i.e. bleeding events were not significantly different between the genetic models investigated (TT vs. CC: RR 1.93; 95% CI 0.86-4.35; p=0.11; TT vs. CC+CT: RR 1.36; 95% CI 0.89-2.09; p=0.16; CT+TT vs. CC: RR 1.20; 95% CI 0.59-2.44; p=0.61). It is suggested that ABCB1 C3435T genotype should be tested for ACS/CAD patients undergoing PCI to ensure optimum therapy of clopidogrel.

    Matched MeSH terms: Coronary Artery Disease/therapy
  17. Jeger RV, Eccleshall S, Wan Ahmad WA, Ge J, Poerner TC, Shin ES, et al.
    JACC Cardiovasc Interv, 2020 06 22;13(12):1391-1402.
    PMID: 32473887 DOI: 10.1016/j.jcin.2020.02.043
    Although drug-eluting stents are still the default interventional treatment of coronary artery disease, drug-coated balloons (DCBs) represent a novel alternative therapeutic strategy in certain anatomic conditions. The effect of DCBs is based on the fast and homogenous transfer of antiproliferative drugs into the vessel wall during single balloon inflation by means of a lipophilic matrix without the use of permanent implants. Although their use is established for in-stent restenosis of both bare-metal and drug-eluting stents, recent randomized clinical data demonstrate a good efficacy and safety profile in de novo small-vessel disease and high bleeding risk. In addition, there are other emerging indications (e.g., bifurcation lesions, large-vessel disease, diabetes mellitus, acute coronary syndromes). Because the interaction among the different delivery balloon designs, doses, formulations, and release kinetics of the drugs used is important, there seems to be no "class effect" of DCBs. On the basis of the amount of recently published data, the International DCB Consensus Group provides this update of previous recommendations summarizing the historical background, technical considerations such as choice of device and implantation technique, possible indications, and future perspectives.
    Matched MeSH terms: Coronary Artery Disease/therapy*
  18. Wan Ahmad WA, Nakayoshi T, Mahmood Zuhdi AS, Ismail MD, Zainal Abidin I, Ino Y, et al.
    Heart Vessels, 2020 Apr;35(4):463-473.
    PMID: 31587103 DOI: 10.1007/s00380-019-01516-9
    Recent clinical trials have raised concerns about the safety and efficacy of ABSORB™ bioresorbable vascular scaffolds (BVS). The difference in the vascular healing process between SYNERGY™ bioabsorbable polymer-coated everolimus-eluting stents (BP-EES) and BVS remains unclear. The aim of the ENHANCE study was to compare vascular healing on BP-EES versus BVS by optical coherence tomography (OCT) and coronary angioscopy (CAS) at 4- and 12-month follow-ups. This is a prospective, non-randomized, single center clinical trial. Thirteen eligible patients with multivessel disease were enrolled. BP-EES and BVS were simultaneously implanted in the same patients, but in different coronary vessels. Imaging follow-up with both OCT and CAS was completed in 11 patients at 12 months. Neointimal coverage rates were similar between the two groups based on OCT measurements. The neointimal thickness of BP-EES was significantly thicker at the 12th month than at the 4th month, whereas the neointimal thickness of BVS did not change between the measurements taken at the 4th and 12th month. Existence of intra-stent thrombus was significantly higher in the BVS group, compared to the BP-EES group. On the other hand, CAS revealed that red-thrombi and yellow-plaque were more frequently observed in BVS at 4 months and up to 12-month follow-ups than in BP-EES. These findings suggested that the evidence of instability remained up to 12 months in the vascular healing with BVS, compared to that with BP-EES. Vascular healing of the stented wall was recognized at the very early phase after BP-EES implantation. However, vascular healing with BVS was still incomplete after 12 months.
    Matched MeSH terms: Coronary Artery Disease/therapy*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links