Displaying all 5 publications

Abstract:
Sort:
  1. Yong GY, Mohamed-Noor J, Ong PY, Suliman NB, Lim CW, Zahari M
    Eur J Ophthalmol, 2021 Feb 07.
    PMID: 33550831 DOI: 10.1177/1120672121992953
    PURPOSE: To report the clinical profile and effectiveness of oral doxycycline as a non-invasive treatment for glaucoma filtering surgery complications.

    METHOD: Prospective case series.

    RESULTS: Doxycycline is widely used in treating corneal melts, ocular surface diseases, meibomian gland disease, recurrent epithelial cell erosion, rosacea, and keratitis sicca. This prospective case series highlights the successful treatment of five patients with leaking blebs and conjunctiva erosion from glaucoma filtration surgery with the use of oral doxycycline. There was no adverse event reported in our cases.

    CONCLUSIONS: This study suggests that oral doxycycline may be a feasible non-surgical treatment modality due to its ability to inhibit collagenolysis, restore the Meibomian gland function, thereby stopping breakdown and promote conjunctival tissue healing.

    Matched MeSH terms: Filtering Surgery
  2. Samsudin A, Eames I, Brocchini S, Khaw PT
    J Glaucoma, 2016 Jan;25(1):e39-45.
    PMID: 25719236 DOI: 10.1097/IJG.0000000000000243
    PURPOSE: ExPress devices are available as P50 and P200 models, the numbers related to their luminal diameters in μm. We compared their Poiseuille's Law-based theoretical resistance values with experimental values and correlated these with their luminal dimensions derived from electron microscopy.

    METHODS: Scanning electron microscopy was performed on P50 and P200 devices. Bench-top flow studies were performed to find the resistances of the devices. Devices were also incorporated into a perfused, ex vivo porcine sclera model to test and compare their control of pressure, with and without overlying scleral flaps, and with trabeculectomies.

    RESULTS: The luminal dimensions of the P200 device were 206.4±3.3 and 204.5±0.9 μm at the subconjunctival space and anterior chamber ends, respectively. Those of the P50 device were 205.0±5.8 and 206.9±3.7 μm, respectively. There were no significant differences between the P200 and P50 devices (all P>0.05). The resistances of the P200 and P50 devices were 0.010±0.001 and 0.054±0.002 mm Hg/μL/min, respectively (P<0.05). Equilibrium pressures with overlying scleral flaps were 17.81±3.30 mm Hg for the P50, 17.31±4.24 mm Hg for the P200, and 16.28±6.67 mm Hg for trabeculectomies (P=0.850).

    CONCLUSIONS: The luminal diameters of both devices are externally similar. The effective luminal diameter of the P50 is much larger than 50 μm. Both devices have low resistance values, making them unlikely to prevent hypotony on their own. They lead to similar equilibrium pressures as the trabeculectomy procedure when inserted under the scleral flap.

    Matched MeSH terms: Filtering Surgery/instrumentation*
  3. Ooi, Edwin I.L., Safinaz, M.K., Ropilah, A.R
    MyJurnal
    This was a 28-year-old mentally-challenged girl with underlying congenital Rubella syndrome. She was bilaterally aphakic after congenital cataract surgery. She then developed bilateral aphakic glaucoma and had to undergo multiple glaucoma filtering surgeries. The most recent procedure she had undergone for her left eye was a second Ahmed valve implantation with an overlying sclera patch. Postoperatively, intraocular pressure was well controlled. However, nine months later, slit lamp examination revealed the tube was adherent to the overlying cornea with surrounding deep and superficial cornea vascularization. Siedel test was negative and intraocular pressure was normal. Subsequently the tube was removed but the plate was left in situ.
    Matched MeSH terms: Filtering Surgery
  4. Din NM, Talat L, Isa H, Tomkins-Netzer O, Barton K, Lightman S
    Graefes Arch Clin Exp Ophthalmol, 2016 Dec;254(12):2439-2448.
    PMID: 27495303
    PURPOSE: To determine whether the second eyes (SE) of patients with bilateral uveitic glaucoma undergoing filtration surgery have more glaucomatous progression in terms of visual acuity, visual field (VF) and optic nerve changes compared to the first eyes (FE).

    METHODS: This retrospective study analysed data of 60 eyes from 30 patients with bilateral uveitic glaucoma who had undergone glaucoma surgery in both eyes on separate occasions. Humphrey VF progression was assessed using the Progressor software.

    RESULTS: The pre-operative IOP between the FE (43.1 ± 7.7 mmHg) and SE (40 ± 8.7 mmHg) was not statistically significant (p = 0.15). IOP reduction was greater in the FE (64 %) than SE (59.7 %) post-operatively, but the mean IOP at the final visit in the FE (12.3 ± 3.9 mmHg) and SE (14.5 ± 7 mmHg) was not statistically different (p = 0.2). There was no significant change in mean logMAR readings pre and post-operatively (0.45 ± 0.6 vs 0.37 ± 0.6, p = 0.4) or between the FE and SE. The number of SE with CDR > 0.7 increased by 23 % compared to the FE. From 23 available VFs, five SE (21.7 %) progressed at a median of five locations (range 1-11 points) with a mean local slope reduction of 1.74 ± 0.45 dB/year (range -2.39 to -1.26), whereas only one FE progressed. However, there was no significant difference between mean global rate of progression between the FE (-0.9 ± 1.6 dB/year) and SE (-0.76 ± 2.1 dB/year, p = 0.17) in the Humphrey VF.

    CONCLUSION: In eyes with bilateral uveitic glaucoma requiring glaucoma surgery, the SEs had more progressed points on VF and glaucomatous disc progression compared to FEs at the final visit.

    Matched MeSH terms: Filtering Surgery/adverse effects*
  5. Mudassar Imran Bukhari S, Yew KK, Thambiraja R, Sulong S, Ghulam Rasool AH, Ahmad Tajudin LS
    Ther Adv Ophthalmol, 2019 08 22;11:2515841419868100.
    PMID: 31489400 DOI: 10.1177/2515841419868100
    Purpose: To determine the role of microvascular endothelial dysfunction as risk factor for primary open angle glaucoma.

    Methods: A cross-sectional study was conducted involving 114 Malay patients with POAG seen at the eye clinic of Hospital Universiti Sains Malaysia. Patients aged between 40 and 80 years who were diagnosed with other types of glaucoma, previous glaucoma filtering surgery or other surgeries except uncomplicated cataract surgery and pterygium surgery were excluded. A total of 101 patients who were followed up for dry eyes, age-related cataracts or post cataracts extraction surgery were recruited as control subjects. Those with family history of glaucoma or glaucoma suspect were excluded. Microvascular endothelial function was assessed using laser Doppler fluximetry and the process of iontophoresis. Iontophoresis with acetylcholine (ACh) and sodium nitroprusside (SNP) was used to measure microvascular endothelium-dependent and endothelium-independent vasodilatations, respectively.

    Results: In general, POAG patients demonstrated lower ACh% and AChmax values compared with controls. There was significant difference in microvascular endothelial function [ACh%: mean, 95% confidence interval = 503.1 (378.0, 628.3), and AChmax: mean, 95% confidence interval = 36.8 (30.2, 43.5)] between primary open angle glaucoma cases (p 

    Matched MeSH terms: Filtering Surgery
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links