Displaying all 4 publications

Abstract:
Sort:
  1. Glazier PS, Mehdizadeh S
    J Biomech, 2019 Sep 20;94:1-4.
    PMID: 31427095 DOI: 10.1016/j.jbiomech.2019.07.044
    The development of methods that can identify athlete-specific optimum sports techniques-arguably the holy grail of sports biomechanics-is one of the greatest challenges for researchers in the field. This 'perspectives article' critically examines, from a dynamical systems theoretical standpoint, the claim that athlete-specific optimum sports techniques can be identified through biomechanical optimisation modelling. To identify athlete-specific optimum sports techniques, dynamical systems theory suggests that a representative set of organismic constraints, along with their non-linear characteristics, needs to be identified and incorporated into the mathematical model of the athlete. However, whether the athlete will be able to adopt, and reliably reproduce, his/her predicted optimum technique will largely be dependent on his/her intrinsic dynamics. If the attractor valley corresponding to the existing technique is deep, or if the attractor valleys corresponding to the existing technique and the predicted optimum technique are in different topographical regions of the dynamic landscape, technical modifications may be challenging or impossible to reliably implement even after extended practice. The attractor layout defining the intrinsic dynamics of the athlete, therefore, needs to be determined to establish the likelihood of the predicted optimum technique being reliably attainable by the athlete. Given the limited set of organismic constraints typically used in mathematical models of athletes, combined with the methodological challenges associated with mapping the attractor layout of an athlete, it seems unlikely that athlete-specific optimum sports techniques will be identifiable through biomechanical optimisation modelling for the majority of sports skills in the near future.
    Matched MeSH terms: Patient-Specific Modeling*
  2. Kamangar S, Badruddin IA, Ameer Ahamad N, Soudagar MEM, Govindaraju K, Nik-Ghazali N, et al.
    Biomed Mater Eng, 2017;28(3):257-266.
    PMID: 28527189 DOI: 10.3233/BME-171672
    The current study investigates the effect of multi stenosis on the hemodynamic parameters such as wall pressure, velocity and wall shear stress in the realistic left coronary artery. Patients CT scan image data of normal and diseased left coronary artery was chosen for the reconstruction of 3D coronary artery models. The diseased 3D model of left coronary artery shows a narrowing of more than 70% and 80% of area stenosis (AS) at the left main stem (LMS) and left circumflex (LCX) respectively. The results show that the decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. The maximum pressure drop was noted across the 80% AS at the left circumflex branch. The recirculation zone was also observed immediate to the stenosis and highest wall shear stress was found across the 80% area stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding on the hemodynamics in realistic coronary artery.
    Matched MeSH terms: Patient-Specific Modeling*
  3. Basri AA, Zuber M, Basri EI, Zakaria MS, Aziz AFA, Tamagawa M, et al.
    Comput Math Methods Med, 2020;2020:9163085.
    PMID: 32454886 DOI: 10.1155/2020/9163085
    This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA.
    Matched MeSH terms: Patient-Specific Modeling/statistics & numerical data
  4. Pahl C, Zare M, Nilashi M, de Faria Borges MA, Weingaertner D, Detschew V, et al.
    J Biomed Inform, 2015 Jun;55:174-87.
    PMID: 25900270 DOI: 10.1016/j.jbi.2015.04.004
    This work investigates, whether openEHR with its reference model, archetypes and templates is suitable for the digital representation of demographic as well as clinical data. Moreover, it elaborates openEHR as a tool for modelling Hospital Information Systems on a regional level based on a national logical infrastructure. OpenEHR is a dual model approach developed for the modelling of Hospital Information Systems enabling semantic interoperability. A holistic solution to this represents the use of dual model based Electronic Healthcare Record systems. Modelling data in the field of obstetrics is a challenge, since different regions demand locally specific information for the process of treatment. Smaller health units in developing countries like Brazil or Malaysia, which until recently handled automatable processes like the storage of sensitive patient data in paper form, start organizational reconstruction processes. This archetype proof-of-concept investigation has tried out some elements of the openEHR methodology in cooperation with a health unit in Colombo, Brazil. Two legal forms provided by the Brazilian Ministry of Health have been analyzed and classified into demographic and clinical data. LinkEHR-Ed editor was used to read, edit and create archetypes. Results show that 33 clinical and demographic concepts, which are necessary to cover data demanded by the Unified National Health System, were identified. Out of the concepts 61% were reused and 39% modified to cover domain requirements. The detailed process of reuse, modification and creation of archetypes is shown. We conclude that, although a major part of demographic and clinical patient data were already represented by existing archetypes, a significant part required major modifications. In this study openEHR proved to be a highly suitable tool in the modelling of complex health data. In combination with LinkEHR-Ed software it offers user-friendly and highly applicable tools, although the complexity built by the vast specifications requires expert networks to define generally excepted clinical models. Finally, this project has pointed out main benefits enclosing high coverage of obstetrics data on the Clinical Knowledge Manager, simple modelling, and wide network and support using openEHR. Moreover, barriers described are enclosing the allocation of clinical content to respective archetypes, as well as stagnant adaption of changes on the Clinical Knowledge Manager leading to redundant efforts in data contribution that need to be addressed in future works.
    Matched MeSH terms: Patient-Specific Modeling
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links