METHODS: A questionnaire based on the Joint Commission International Accreditation Standards was electronically sent to 3 institutions each in 10 geographical regions across 9 Asian countries. Questions addressing 45 practices were divided into 3 categories. A five-tier scale with numerical scores was used to evaluate safety practices in each institution. Responses obtained from three institutions in the United States were used to validate the execution rate of each surveyed safety practice.
RESULTS: The institutional response rate was 70.0% (7 Asian regions, 21 institutions). 44 practices (all those surveyed except for the application of wrist tags for identifying patients with fall risks) were validated using the US participants. Overall, the Asian participants reached a consensus on 89% of the safety practices. Comparatively, most Asian participants did not routinely perform three pre-procedural practices in the examination appropriateness topic.
CONCLUSION: Based on the responses from 21 participating Asian institutions, most routinely perform standard practices during radiological examinations except when it comes to examination appropriateness. This study can provide direction for safety policymakers scrutinizing and improving regional standards of care.
ADVANCES IN KNOWLEDGE: This is the first multicenter survey study to elucidate pre-procedural safety practices in radiological examinations in seven Asian regions.
METHODS: 3317 raw digital mammograms were processed with Volpara(®) (Matakina Technology Ltd, Wellington, New Zealand) to obtain fibroglandular tissue volume (FGV), breast volume (BV) and VBD. Errors in parameters including CBT, kVp, filter thickness and mAs were simulated by varying them in the Digital Imaging and Communications in Medicine (DICOM) tags of the images up to ±10% of the original values. Errors in detector gain and offset were simulated by varying them in the Volpara configuration file up to ±10% from their default values. For image noise, Gaussian noise was generated and introduced into the original images.
RESULTS: Errors in filter thickness, mAs, detector gain and offset had limited effects on FGV, BV and VBD. Significant effects in VBD were observed when CBT, kVp, detector offset and image noise were varied (p
METHODS: The study comprised 106 chronic kidney disease (CKD) patients and 203 control subjects. Conventional ultrasound was performed to measure the kidney length and cortical thickness. SWE imaging was performed to measure renal parenchymal stiffness. Diagnostic performance of SWE and conventional ultrasound were correlated with serum creatinine, urea levels and eGFR.
RESULTS: Pearson's correlation coefficient revealed a negative correlation between YM measurements and eGFR (r = -0.576, p < 0.0001). Positive correlations between YM measurements and age (r = 0.321, p < 0.05), serum creatinine (r = 0.375, p < 0.0001) and urea (r = 0.287, p < 0.0001) were also observed. The area under the receiver operating characteristic curve for SWE (0.87) was superior to conventional ultrasound alone (0.35-0.37). The cut-off value of less or equal to 4.31 kPa suggested a non-diseased kidney (80.3% sensitivity, 79.5% specificity).
CONCLUSION: SWE was superior to renal length and cortical thickness in detecting CKD. A value of 4.31 kPa or less showed good accuracy in determining whether a kidney was diseased or not. Advances in knowledge: On SWE, CKD patients show greater renal parenchymal stiffness than non-CKD patients. Determining a cut-off value between normal and diseased renal parenchyma may help in early non-invasive detection and management of CKD.
METHODS: The imaging performance of the camera system was assessed quantitatively and qualitatively at different source depths, source to collimator distances (SCD), activity levels, acquisition times and source separations, utilising bespoke phantoms.
RESULTS: The system sensitivity and spatial resolution of the HGC for 125I were 0.41 cps/MBq (at SCD 48 mm) and 1.53 ± 0.23 mm (at SCD 10 mm) respectively. The camera was able to detect the 125I seed at a SCD of 63 mm (with no scattering material in place) in images recorded within a 1-min acquisition time. The detection of the seeds beneath scattering material (simulating deep-seated tumours) was limited to depths of less than 20 mm beneath the skin surface with a SCD of 63 mm and seed activity of 2.43 MBq. Subjective assessments of the hybrid images acquired showed the capability of the HGC for localising the 125I seeds.
CONCLUSION: This preliminary ex vivo study demonstrates that the HGC is capable of detecting 125I seeds and could be a useful tool in radioactive seed localisation with the added benefit of providing hybrid optical γ images for guiding breast conserving surgery.
ADVANCES IN KNOWLEDGE: The SFOV HGC could provide high resolution fused optical-gamma images of 125I radioactive seeds indicating the potential use in intraoperative surgical procedure such as RSL.
METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods.
RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp.
CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.
METHODS: 5 radiologists read 1 identical test set of 200 mammographic (180 normal cases and 20 abnormal cases) 3 times and were requested to adhere to 3 different recall rate conditions: free recall, 15% and 10%. The radiologists were asked to mark the locations of suspicious lesions and provide a confidence rating for each decision. An independent expert radiologist identified the various types of cancers in the test set, including the presence of calcifications and the lesion location, including specific mammographic density.
RESULTS: Radiologists demonstrated lower sensitivity and receiver operating characteristic area under the curve for non-specific density/asymmetric density (H = 6.27, p = 0.04 and H = 7.35, p = 0.03, respectively) and mixed features (H = 9.97, p = 0.01 and H = 6.50, p = 0.04, respectively) when reading at 15% and 10% recall rates. No significant change was observed on cancer characterized with stellate masses (H = 3.43, p = 0.18 and H = 1.23, p = 0.54, respectively) and architectural distortion (H = 0.00, p = 1.00 and H = 2.00, p = 0.37, respectively). Across all recall conditions, stellate masses were likely to be recalled (90.0%), whereas non-specific densities were likely to be missed (45.6%).
CONCLUSION: Cancers with a stellate mass were more easily detected and were more likely to continue to be recalled, even at lower recall rates. Cancers with non-specific density and mixed features were most likely to be missed at reduced recall rates. Advances in knowledge: Internationally, recall rates vary within screening mammography programs considerably, with a range between 1% and 15%, and very little is known about the type of breast cancer appearances found when radiologists interpret screening mammograms at these various recall rates. Therefore, understanding the lesion types and the mammographic appearances of breast cancers that are affected by readers' recall decisions should be investigated.
METHODS: 50 POAG patients and 50 normal subjects were recruited and an MRI brain with T1-magnetization-prepared rapid gradient-echo was performed. Medial temporal lobe and parietal lobe atrophy were by MTA and PCA/Koedam scoring. The score of the PCA and MTA were compared between the POAG group and the controls.
RESULTS: There was a significant statistical difference between PCA score in POAG and the healthy control group (p-value = 0.026). There is no statistical difference between MTA score in POAG compared to the healthy control group (p-value = 0.58).
CONCLUSION: This study suggests a correlation between POAG and PCA score. Potential application of this scoring method in clinical diagnosis and monitoring of POAG patients.
ADVANCES IN KNOWLEDGE: The scoring method used in AD may also be applied in the diagnosis and monitoring of POAGMRI brain, specifically rapid volumetric T1 spoiled gradient echo sequence, may be applied in POAG assessment.
METHODS: The review was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus database up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk-of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303.
RESULTS: A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in systematic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patients.
CONCLUSIONS: Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE reproducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful.
ADVANCES IN KNOWLEDGE: This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.
METHOD: Stereolithography (SLA) 3D Print technology using SLA resin and Anycubic SLA printer were employed. A plastic tubing was used to connect the 3D printed kidney and bladder as the ureter. This simulation model permits fluoroscopic guided filling of "pelvicalyceal system" with contrast as well as ureteric stenting, guidewire and drainage catheter manipulation. Effectiveness of the model to attain skills for nephrostomy exchange and ureteric stenting was obtained via questionnaire from trainees prior to and after utilising the model.
RESULT: The 3D printing simulation model of the kidney, ureter and bladder system enable trainees to perform nephrostomy exchange, nephrostogram and antegrade stenting. Participants felt more confident to perform the procedures as they were more familiar with the procedure. Besides that, participants felt their wire and catheter manipulation skills have improved after using the simulation model.
CONCLUSION: Neph-ex simulation model is safe and effective for hands-on training in improving proficiency of fluoroscopy-guided nephrostomy exchange and antegrade ureteric stenting.
METHODS:: A literature search was done for articles published between 2002 and 2017 on Medline electronic databases. Of 249 titles identified, 38 fulfilled the inclusion criteria, with 14 articles related to quantifiable imaging parameters (heterogeneity, vascularity, diffusion, cell density, infiltrations, perfusion, and metabolite changes) and 24 articles relevant to molecular biomarkers linked to imaging.
RESULTS:: Genes found to correlate with various imaging phenotypes were EGFR, MGMT, IDH1, VEGF, PDGF, TP53, and Ki-67. EGFR is the most studied gene related to imaging characteristics in the studies reviewed (41.7%), followed by MGMT (20.8%) and IDH1 (16.7%). A summary of the relationship amongst glioma morphology, gene expressions, imaging characteristics, prognosis and therapeutic response are presented.
CONCLUSION:: The use of radiogenomics can provide insights to understanding tumour biology and the underlying molecular pathways. Certain MRI characteristics that show strong correlations with EGFR, MGMT and IDH1 could be used as imaging biomarkers. Knowing the pathways involved in tumour progression and their associated imaging patterns may assist in diagnosis, prognosis and treatment management, while facilitating personalised medicine.
ADVANCES IN KNOWLEDGE:: Radiogenomics can offer clinicians better insight into diagnosis, prognosis, and prediction of therapeutic responses of glioma.
METHODS: We reviewed complications in a total of 85 consecutive patients who underwent cryoablation using a liquid nitrogen-based system in various lesions between April 2017 and October 2022. There were none liver and renal lesions. Complications were categorized using the Society of Interventional Radiology (SIR) classification.
RESULTS: 85 patients were treated for 96 lesions in the bone (36.4%; 35 of 96), lung (18.8%; 18 of 96), and soft tissue (44.8%; 43 of 96). The primary technical success rate was 97.7% (83 of 85). The total grade 2 and 1 complication rates were 5.2% (5/96) and 20.8% (20/96), respectively. Two patients had asymptomatic pulmonary embolisms incidentally noted at the 24-hour follow-up computed tomography (grade 2). The most frequent complications were simple and hemorrhagic pleural effusions (18.7%; 18 of 96). Lung procedures had the highest complication rate where 13 patients (72.2%; 13 of 18) reporting complications, including two cases of symptomatic hydropneumothorax requiring drainage (grade 2) and an additional two days of hospital stay. Eight patients (24.2%; 8 of 33) with bone lesions and four (9.3%; 4 of 43) with soft tissue lesions experienced complications.
CONCLUSION: Cryoablation using a liquid nitrogen-based system is safe, with only minor complications observed.
METHODS: Ninety-eight healthy volunteers were recruited. SWE was performed on quadriceps, suprapatellar, infrapatellar, and Achilles entheses. The stiffness measurements were measured in shear wave velocity (SWV).
RESULTS: Mann-Whitney test revealed insignificant difference in SWV among gender. Wilcoxon signed-rank test showed significant difference in SWV between left and right Achilles entheses. Spearman correlation test revealed moderate negative correlation between SWV and age group in quadriceps (ρ, -0.45, P