  1. Sidhu P, Shankargouda S, Dicksit DD, Mahdey HM, Muzaffar D, Arora S
    J Endod, 2016 Apr;42(4):622-5.
    PMID: 26850688 DOI: 10.1016/j.joen.2015.12.027
    INTRODUCTION: Use of mobile phone has been prohibited in many hospitals to prevent interference with medical devices. Electromagnetic radiation emitted from cellular phones might interfere with electronic working length determination. The purpose of this in vitro study was to evaluate the effect of a smart phone (Samsung Galaxy Note Edge) on working length determination of electronic apex locators (EALs) Propex II and Rootor.

    METHODS: Fifteen intact, non-carious single-rooted teeth were decoronated at the cementoenamel junction. Visually, working length was determined by using a #15 K-file under stereomicroscope (×20). The effect of cellular phones on electronic working length (EWL) was determined under 2 experimental settings: (1) in a closed room with poor signal strength and (2) in a polyclinic set up with good signal strength and 5 conditions: (1) electronically, without cellular phone in room; (2) electronically, with cellular phone in physical contact with EAL; (3) electronically, with mobile phone in physical contact with EAL and in calling mode for a period of 25 seconds; (4) electronically, mobile phone placed at a distance of 40 cm from the EAL; and (5) electronically, mobile phone placed at a distance of 40 cm and in calling mode for a period of 25 seconds. The EWL was measured 3 times per tooth under each condition. Stability of the readings was scored from 1 to 3: (1) good stability, (2) stable reading after 1 attempt, and (3) stable reading after 2 attempts. The data were compared by using analysis of variance.

    RESULTS: The EWL measurements were not influenced by the presence of cellular phone and could be determined under all experimental conditions.

    CONCLUSIONS: Within the limitations of this study, it can be concluded that mobile phones do not interfere with the EWL determination.

    Matched MeSH terms: Electrical Equipment and Supplies
  2. Lowther AH
    Matched MeSH terms: Equipment and Supplies, Hospital
  3. Mallepaddi PC, Lai MY, Podha S, Ooi CH, Liew JW, Polavarapu R, et al.
    Am J Trop Med Hyg, 2018 09;99(3):704-708.
    PMID: 29943720 DOI: 10.4269/ajtmh.18-0177
    The present study aims to develop a method for rapid diagnosis of malaria using loop-mediated isothermal amplification (LAMP) combined with a lateral flow device (LFD). By adding the biotin-labeled and fluorescein amidite-labeled loop primers to the LAMP reaction solution, the end product can be visualized on a LFD. The entire procedure takes approximately 42 minutes to complete, LAMP assay exhibited high sensitivity, as the detection limit was 0.01 pg/μL for all five Plasmodium species. It was demonstrated that all Plasmodium knowlesi (N = 90) and Plasmodium vivax (N = 56) were positively amplified by LAMP-LFD assay, whereas healthy donor samples (N = 8) were negative. However, not all mixed infections were positive, and other infected nonmalaria samples were negative. Loop-mediated isothermal amplification-LFD represents a robust approach with potential suitability for use in resource-constrained laboratories. We believe that LAMP-LFD has a potential to be developed as point-of-care diagnostic tool in future.
    Matched MeSH terms: Equipment and Supplies
  4. Ismail MT, Arshat H, Halim AJ
    Malays J Reprod Health, 1988 Dec;6(2):90-6.
    PMID: 12342172
    PIP: In 1986, single puncture laparoscopic application of the Filshie clip was introduced into Malaysia's National Population and Family Development Board's female sterilization program for an evaluation. A total of 42 female sterilizations were performed by this method between June 1986 and December 1986. Laparoscopy was performed on an outpatient basis under local anesthesia. In 37 cases, the sterilization was interval. Filshie clips were successfully applied to the fallopian tubes of 40 women; in the remaining 2 cases, the latching mechanism jammed and Falope rings were used instead. The average time from application of 1st clip to skin closure was 10 minutes. During clip application, technical problems (faulty applicator, clip fell into the pelvic cavity, failure of latching mechanism) were encountered in 4 cases and surgical difficulties (poor visualization, hydrosalpinx, and tubal adhesions) occurred in 10 cases. In general, complications were minimal: 1 patient developed cynosis after anesyhesia (Pethidine) injection, the omentum was torn during introduction of the trocar in another, and a 3rd patient developed thrombophlebitis at the intravenous site. Only 1 pregnancy was recorded during the follow-up period; this occurred 15 months postoperatively and was intrauterine. Given the facts that this procedure is easy to learn, fast and simple, associated with no more complications than other laparoscopic procedures, and is cosmetically more acceptable to women, its more widespread application is recommended.
    Matched MeSH terms: Equipment and Supplies
  5. Khalid HM, Helander MG, Hood NA
    Appl Ergon, 2013 Sep;44(5):671-9.
    PMID: 22944486 DOI: 10.1016/j.apergo.2012.06.005
    The purpose of this study was to analyze people's attitudes to disasters by investigating how people feel, behave and think during disasters. We focused on disasters induced by humans, such as terrorist attacks. Two types of textual information were collected - from Internet blogs and from research papers. The analysis enabled forecasting of attitudes for the design of proactive disaster advisory scheme. Text was analyzed using a text mining tool, Leximancer. The outcome of this analysis revealed core themes and concepts in the text concerning people's attitudes. The themes and concepts were sorted into three broad categories: Affect, Behaviour, and Cognition (ABC), and the data was visualized in semantic maps. The maps reveal several knowledge pathways of ABC for developing attitudinal ontologies, which describe the relations between affect, behaviour and cognition, and the sequence in which they develop. Clearly, terrorist attacks induced trauma and people became highly vulnerable.
    Matched MeSH terms: Equipment and Supplies
  6. Ho NK
    Singapore Med J, 1999 Sep;40(9):558-60.
    PMID: 10628240
    Matched MeSH terms: Equipment and Supplies, Hospital
  7. Phua KL
    New Solut, 2008;18(2):221-31.
    PMID: 18511398 DOI: 10.2190/NS.18.2.k
    When public health researchers study the health effects of disasters (whether "naturally-occurring," disasters due to failure of technology, or disasters due to terrorism), some aspects of the post-disaster situation of victims are often overlooked. Social science research has shown that the vast majority of people tend to behave altruistically during and after a disaster. Nevertheless, cases of victimization of survivors do occur. They can include post-disaster victimization of survivors by other individuals (including fellow survivors, opportunistic outsiders, and even unethical aid workers and rogue members of the police, armed forces or international organizations such as the United Nations), groups (such as organized criminal gangs) and institutions (through neglect, incompetence, bureaucratic inefficiency or through institutionalized discriminatory practices). In this article, various kinds of post-disaster victimization that can occur are discussed.
    Matched MeSH terms: Equipment and Supplies
  8. Arshat H, Puraviappan AP, Thambu J, Ali J, Harun R
    Malays J Reprod Health, 1984 Jun;2(1):14-9.
    PMID: 12267516
    Matched MeSH terms: Equipment and Supplies