Displaying publications 21 - 26 of 26 in total

Abstract:
Sort:
  1. Verghese I, Sivaraj R, Lai YK
    Aust N Z J Ophthalmol, 1996 May;24(2):117-20.
    PMID: 9199741
    PURPOSE: To determine if adequate anesthesia and akinesia could be obtained using an inferonasal quadrant sub-Tenons anaesthesia for cataract surgery.
    METHODS: The sub-Tenons method of local anaesthesia was used in 50 patients undergoing extracapsular cataract extraction and lens implantation. The technique following was that described by JD Stevens in his study of 50 patients. Posterior sub-Tenons space was approached through a conjunctival incision in the inferonasal quadrant and the anaesthetic solution delivered by an irrigating cannula. The patients were assessed for residual ocular movements just before surgery. Effectiveness of anaesthesia was assessed during surgery using a verbal pain rating score. Scoring was based on the concept of a visual analogue pain score chart.
    RESULTS: Total akinesia was obtained in 20% patients and total anaesthesia in 24% patients. The remainder of the patients had adequate akinesia and anaesthesia to proceed with and complete the surgery.
    CONCLUSION: This method provides satisfactory anaesthesia for cataract surgery.
    Matched MeSH terms: Eye Movements/drug effects
  2. Ng, Benjamin Han Sim, Prakash Supahiah, Goh, Siew Yuen
    MyJurnal
    Cerebral venous thrombosis (CVT) is a neurological condition occurring because of thrombosis involving the cerebral venous sinuses. This case report is an unusual clinical manifestation of cerebral venous thrombosis in a 76-year-old Chinese man who presented with restricted eye movement and double vision. Despite extensive investigation, there was no better explanation for his clinical symptom and sign apart from cerebral venous thrombosis which was confirmed by magnetic resonance venography (MRV) of the brain. Once cerebral venous thrombosis was diagnosed, he was initiated on anticoagulation and discharged with oral warfarin. This case emphasizes the need to consider cerebral venous thrombosis as one of the rare causes of complex ophthalmoplegia especially when typical cardiovascular risk factors are lacking in an individual.
    Matched MeSH terms: Eye Movements
  3. Petre-Quadens O, Hussain H, Balaratnan C
    Acta Neurol Belg, 1975 Mar;75(2):85-92.
    PMID: 168717
    The Temiars are a tribe of negroid pygmies of basically Proto-Malaysian affinities. Field-work in the Malaysian jungle provided some observations on the sleep-wakefulness cycle of two young Temiar adults. This cycle was monophasic circumstances permitting. Their rest-activity cycle at night was similar in the jungle and in the laboratory. Polygraphic total night-sleep recordings were made with both of them in the EEG laboratory in the Hospital Besar in Kuala Lumpur. The eye-movement frequencies of PS were compared with those from young adults of the West. Although the differences were not statistically significant, the Rem-densities of the Temiars were constantly at the low side. The significance of the results are being discussed.
    Matched MeSH terms: Eye Movements
  4. Zakaria MN, Abdullah R, Nik Othman NA
    Ear Hear, 2018 11 22;40(4):1039-1042.
    PMID: 30461445 DOI: 10.1097/AUD.0000000000000676
    OBJECTIVES: Post-auricular muscle response (PAMR) is a large myogenic potential that can be useful in estimating behavioral hearing thresholds when the recording protocol is optimal. The main aim of the present study was to determine the influence of stimulus repetition rate on PAMR threshold.

    DESIGN: In this repeated-measures study, 20 normally hearing adults aged between 18 and 30 years were recruited. Tone bursts (500, 1000, 2000, and 4000 Hz) were used to record PAMR thresholds at 3 different stimulus repetition rates (6.1/s, 11.1/s, and 17.1/s).

    RESULTS: Statistically higher PAMR thresholds were found for the faster stimulus rate (17.1/s) compared with the slower stimulus rate (6.1/s) (p < 0.05). For all stimulus rates and frequencies, significant correlations were found between PAMR and pure-tone audiometry thresholds (r = 0.62 to 0.82).

    CONCLUSIONS: Even though the stimulus rate effect was significant at most of the tested frequencies, the differences in PAMR thresholds between the rates were small (<5 dB). Nevertheless, based on the correlation results, we suggest the use of 11.1/s stimulus rate when recording PAMR thresholds.

    Matched MeSH terms: Eye Movements
  5. Teoh Y, Wallis E, Stephen ID, Mitchell P
    Cognition, 2017 02;159:48-60.
    PMID: 27886521 DOI: 10.1016/j.cognition.2016.11.003
    Past research tells us that individuals can infer information about a target's emotional state and intentions from their facial expressions (Frith & Frith, 2012), a process known as mentalising. This extends to inferring the events that caused the facial reaction (e.g. Pillai, Sheppard, & Mitchell, 2012; Pillai et al., 2014), an ability known as retrodictive mindreading. Here, we enter new territory by investigating whether or not people (perceivers) can guess a target's social context by observing their response to stimuli. In Experiment 1, perceivers viewed targets' responses and were able to determine whether these targets were alone or observed by another person. In Experiment 2, another group of perceivers, without any knowledge of the social context or what the targets were watching, judged whether targets were hiding or exaggerating their facial expressions; and their judgments discriminated between conditions in which targets were observed and alone. Experiment 3 established that another group of perceivers' judgments of social context were associated with estimations of target expressivity to some degree. In Experiments 1 and 2, the eye movements of perceivers also varied between conditions in which targets were observed and alone. Perceivers were thus able to infer a target's social context from their visible response. The results demonstrate an ability to use other minds as a window onto a social context that could not be seen directly.
    Matched MeSH terms: Eye Movements
  6. Wajih WA, Shaharuddin B, Razak NH
    J Oral Maxillofac Surg, 2011 Jun;69(6):1740-4.
    PMID: 21272979 DOI: 10.1016/j.joms.2010.07.053
    A normally restored orbital structure after reconstructive surgery would accelerate the return of orbital function. The aim of the present study was to compare the outcomes of 2 orbital implants: autogenous grafts and porous polyethylene (Medpor).
    Matched MeSH terms: Eye Movements
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links