Displaying publications 21 - 28 of 28 in total

Abstract:
Sort:
  1. Azlan A, Nasir NN, Shamsudin N, Rahman HA, Khoo HE, Razman MR
    BMC Public Health, 2015;15:683.
    PMID: 26194098 DOI: 10.1186/s12889-015-2044-3
    Exposure to PCDD/PCDF (dioxin and furan) through consumption of fish and shellfish is closely related to the occurrence of skin diseases, such as chloracne and hyperpigmentation. This study aimed to determine the exposure of PCDD/PCDF and its congeners in fish and shellfish obtained from different regions of the Straits of Malacca among the fishing community.
    Matched MeSH terms: Occupational Exposure/analysis*
  2. Aziz SA, Nuawi MZ, Nor MJ
    J Occup Health, 2015;57(6):513-20.
    PMID: 26269278 DOI: 10.1539/joh.14-0206-OA
    OBJECTIVE: The objective of this study was to present a new method for determination of hand-arm vibration (HAV) in Malaysian Army (MA) three-tonne truck steering wheels based on changes in vehicle speed using regression model and the statistical analysis method known as Integrated Kurtosis-Based Algorithm for Z-Notch Filter Technique Vibro (I-kaz Vibro).

    METHODOLOGY: The test was conducted for two different road conditions, tarmac and dirt roads. HAV exposure was measured using a Brüel & Kjær Type 3649 vibration analyzer, which is capable of recording HAV exposures from steering wheels. The data was analyzed using I-kaz Vibro to determine the HAV values in relation to varying speeds of a truck and to determine the degree of data scattering for HAV data signals.

    RESULTS: Based on the results obtained, HAV experienced by drivers can be determined using the daily vibration exposure A(8), I-kaz Vibro coefficient (Ƶ(v)(∞)), and the I-kaz Vibro display. The I-kaz Vibro displays also showed greater scatterings, indicating that the values of Ƶ(v)(∞) and A(8) were increasing. Prediction of HAV exposure was done using the developed regression model and graphical representations of Ƶ(v)(∞). The results of the regression model showed that Ƶ(v)(∞) increased when the vehicle speed and HAV exposure increased.

    DISCUSSION: For model validation, predicted and measured noise exposures were compared, and high coefficient of correlation (R(2)) values were obtained, indicating that good agreement was obtained between them. By using the developed regression model, we can easily predict HAV exposure from steering wheels for HAV exposure monitoring.

    Matched MeSH terms: Occupational Exposure/analysis*
  3. Armstrong RW, Rood MJ, Sani S, Mohamed M, Rashid M, Jab AT, et al.
    Asia Pac J Public Health, 2001;13(1):24-9.
    PMID: 12109256 DOI: 10.1177/101053950101300106
    The objective of this study was to establish baseline data about air pollutants potentially related to nasopharyngeal carcinoma (NPC) in the Federal Territory and Selangor, Malaysia. During 1991-1993, ambient air quality was monitored at 42 work sites representing ten industrial sectors: adhesive manufacturing, foundries, latex processing, metalworking, plywood/veneer milling, ricemilling, rubber tire manufacturing, sawmilling, shoemaking, and textile related industries. At each work site, aerosol particle size distributions and concentrations of formaldehyde, benzene, toluene, isopropyl alcohol, and furfural were measured. Mean aerosol particle concentrations ranged from 61 micrograms/m3 in foundries to 5,578 micrograms/m3 in ricemills, with five industries (adhesives, metalworking, ricemilling, sawmilling, and shoemaking) exceeding the US EPA 24-hr ambient air standard for PM-10. Formaldehyde concentrations exceeded the threshold limit value (TLV) in adhesives factories. Other vapours and elements measured were well below TLVs.
    Matched MeSH terms: Occupational Exposure/analysis*
  4. Daud R, Maeda S, Kameel NN, Ripin MY, Bakrun N, Md Zein R, et al.
    Ind Health, 2004 Apr;42(2):189-95.
    PMID: 15128168
    The purpose of this paper is to clarify the reference vibrotactile perception thresholds (VPT) for healthy people in Malaysia. The measurement equipment standard, ISO 13091-1, of the vibrotactile perception thresholds for the assessment of nerve dysfunction and the analysis and interpretation of measurements at the fingertips standard, ISO 13091-2, were published in ISO/TC108/SC4/WG8 on 2001 and 2003 individually. In the ISO 13091-2 standard, the reference VPT data were obtained from few research papers. Malaysian people's VPT data don't include to this standard. In Malaysia, when the VPT is using to diagnose of the hand-arm vibration syndrome, the reference VPT data need to compare with the worker's ones. But, Malaysia does not have the reference VPT data yet. So, in this paper, the VPT was measured by using ISO 13091-1 standard equipment to obtain the reference data for Malaysian people. And these data were compared with the ISO reference data on the ISO 13091-2 standard. From the comparison of these data, it was clear that the Malaysian healthy people's VPT data were consistent with the reference data of the ISO 13091-2 standard.
    Matched MeSH terms: Occupational Exposure/analysis
  5. Reuben U, Ismail AF, Ahmad AL, Maina HM, Daud A
    PMID: 31013942 DOI: 10.3390/ijerph16081334
    : The chemicals from laboratories pose a significant risk forinducing erythema, an abnormal redness of the skin, as a result of poor occupational and environmental factors that promote hypersensitivity to a chemical agent. The aim of this present study was to determine the occupational and environmental risk factors influencing the inducement of erythema in laboratory workers due to exposure to chemicals. This was a cross-sectional study on a population-based sample of Nigerian university laboratory workers. Data were collected using the erythema index meter and an indoor air control meter. The study included 287 laboratory workers. The laboratory workers who properly used personal protective equipment (PPE) were 60% less likely to have induced erythema (adjusted odds ratio (AOR) = 0.40; 95% confidence interval CI: 0.22-0.77; probability value p = 0.011). The chemical mixture exceeding the permissible exposure limit (PEL) was found to have a small effect in inducing the erythema (AOR = 4.22; 95%CI: 2.88-12.11; p = 0.004). Most of the sampled laboratories where the respondents worked had unsuitable temperatures (AOR = 8.21; 95% CI: 4.03-15.01; p = 0.001). Erythema was more frequently found in the respondents who spent 4-5h in the laboratory (AOR = 3.11; 95%CI: 1.77-9.23; p = 0.001). However, high levels of ventilation reduce the likelihood of erythema in a laboratory by 82% (0.18). Multiple logistic regressions revealed that PPE, PEL, exposure time, temperature, and ventilation were the probable predictive factors associated with the inducement of erythema. Providing better educational knowledge and improving the attitude towards hazards and safety in a laboratory would lead to reduced rates of new cases.
    Matched MeSH terms: Occupational Exposure/analysis*
  6. Al-Mohammed HI, Sulieman A, Mayhoub FH, Salah H, Lagarde C, Alkhorayef M, et al.
    Sci Rep, 2021 Jul 15;11(1):14557.
    PMID: 34267237 DOI: 10.1038/s41598-021-93342-1
    Worldwide, thyroid cancer accounts for some 10% of total cancer incidence, most markedly for females. Thyroid cancer radiotherapy, typically using 131I (T1/2 8.02 days; β- max energy 606 keV, branching ratio 89.9%), is widely adopted as an adjunct to surgery or to treat inoperable cancer and hyperthyroidism. With staff potentially receiving significant doses during source preparation and administration, radiation protection and safety assessment are required in ensuring practice complies with international guidelines. The present study, concerning a total of 206 patient radioiodine therapies carried out at King Faisal Specialist Hospital and Research Center over a 6-month period, seeks to evaluate patient and occupational exposures during hospitalization, measuring ambient doses and estimating radiation risk. Using calibrated survey meters, patient exposure dose-rate estimates were obtained at a distance of 30-, 100- and 300 cm from the neck region of each patient. Occupational and ambient doses were measured using calibrated thermoluminescent dosimeters. The mean and range of administered activity (AA, in MBq) for the thyroid cancer and hyperthyroidism treatment groups were 4244 ± 2021 (1669-8066), 1507.9 ± 324.1 (977.9-1836.9), respectively. The mean annual occupational doses were 1.2 mSv, that for ambient doses outside of the isolation room corridors were found to be 0.2 mSv, while ambient doses at the nursing station were below the lower limit of detection. Exposures to staff from patients being treated for thyroid cancer were less compared to hyperthyroidism patients. With a well-defined protocol, also complying with international safety requirements, occupational exposures were found to be relatively high, greater than most reported in previous studies.
    Matched MeSH terms: Occupational Exposure/analysis*
  7. LaDou J, Rohm T
    Int J Occup Environ Health, 1998 Jan-Mar;4(1):1-18.
    PMID: 10026464
    High-technology microelectronics has a major presence in countries such as China, India, Indonesia, and Malaysia, now the third-largest manufacturer of semiconductor chips. The migration of European, Japanese, and American companies accommodates regional markets. Low wage rates and limited enforcement of environmental regulations in developing countries also serve as incentives for the dramatic global migration of this industry. The manufacture of microelectonics products is accompanied by a high incidence of occupational illnesses, which may reflect the widespread use of toxic materials. Metals, photoactive chemicals, solvents, acids, and toxic gases are used in a wide variety of combinations and workplace settings. The industry also presents problems of radiation exposure and various occupational stressors, including some unresolved ergonomic issues. The fast-paced changes of the technology underlying this industry, as well as the stringent security precautions, have added to the difficulty of instituting proper health and safety measures. Epidemiologic studies reveal an alarming increase in spontaneous abortions among cleanroom manufacturing workers; no definitive study has yet identified its cause. Other health issues, including occupational cancer, are yet to be studied. The microelectronics industry is a good example of an industry that is exported to many areas of the world before health and safety problems are properly addressed and resolved.
    Matched MeSH terms: Occupational Exposure/analysis
  8. Hamzah NA, Mohd Tamrin SB, Ismail NH
    Int J Occup Environ Health, 2016 07;22(3):224-232.
    PMID: 27392157 DOI: 10.1080/10773525.2016.1207040
    BACKGROUND: Metallic dust is a heterogeneous substance with respiratory sensitizing properties. Its long term exposure adversely affected lung function, thus may cause acute or chronic respiratory diseases.

    METHODS: A cross-sectional study was conducted in a steel factory in Terengganu, Malaysia to assess the metal dust exposure and its relationship to lung function values among 184 workers. Metal dust concentrations values (Co, Cr, and Ni) for each worker were collected using air personal sampling. Lung function values (FEV1, FVC, and %FEV1/FVC) were determined using spirometer.

    RESULTS: Exposure to cobalt and chromium were 1-3 times higher than permissible exposure limit (PEL) while nickel was not exceeding the PEL. Cumulative of chromium was the predictor to all lung function values (FEV1, FVC, and %FEV1/FVC). Frequency of using mask was positively associated with FVC (Adj b = 0.263, P = 0.011) while past respiratory illnesses were negatively associated with %FEV1/FVC (Adj b = -1.452, P = 0.026). Only few workers (36.4%) were found to wear their masks all times during the working hours.

    CONCLUSIONS: There was an exposure-response relationship of cumulative metal dust exposure with the deterioration of lung function values. Improvement of control measures as well as proper and efficient use or personal protection equipment while at work could help to protect the respiratory health of workers.

    Matched MeSH terms: Occupational Exposure/analysis