Displaying publications 21 - 40 of 67 in total

Abstract:
Sort:
  1. Cheong YM, Jegathesan M, Ansary A, Othman M
    Med J Malaysia, 1990 Mar;45(1):42-8.
    PMID: 2152068
    The prevalence of Enterotoxigenic Escherichia coli (ETEC) in 433 stool samples from diarrhoeal cases of all ages was studied using two commercially available test kits for the detection of heat labile toxin (LT) and the infant mouse assay for the heat stable toxin (ST). 16 samples (3.7%) were positive for ETEC, of which nine were producing ST alone, six LT alone and only one was producing both LT and ST. Although the percentage of isolation rate was low, its occurrence was almost as common as the Shigella spp and Salmonella spp in the same study. Of the two test kits examined, the Phadebact ETEC-LT Test 50 (Pharmacia Diagnostics, Uppsala, Sweden) was found to be more suitable for use in a routine diagnostic laboratory. Ten out of 12 (83%) of the strains tested were resistant to one or more antibiotics.
    Matched MeSH terms: Reagent Kits, Diagnostic
  2. Ch'ng SL
    Med J Malaysia, 1987 Dec;42(4):225-9.
    PMID: 3454393
    Matched MeSH terms: Reagent Kits, Diagnostic*
  3. Fazlina N, Maha A, Zarina AL, Hamidah A, Zulkifli SZ, Cheong SK, et al.
    Malays J Pathol, 2008 Dec;30(2):87-93.
    PMID: 19291917
    Multidrug resistance (MDR) is believed to be responsible for poor response of patients towards chemotherapy particularly patients with acute myeloid leukemia (AML) and acute lymphoblastic leukemia (ALL). The best-characterized resistance mechanism is the one mediated by permeability-glycoprotein (P-gp) encoded by MDR1 gene, which is responsible for drug efflux. We studied P-gp and multidrug resistance-associated protein 1 (MRP1) expression and functional activities in 43 newly diagnosed acute leukemia cases (19 paediatric ALL cases and 24 adult AML cases). The expression and functional activities were examined using flow cytometry and MultiDrugQuant assay kit (involving calcein AM uptake and efflux). P-gp and MRP1 expression and its functional activities were observed in 68.4% of paediatric ALL. In adult AML cases, all cases expressed MRP1 and its functional activities but only 58.3% were positive for P-gp and its functional activities. We were able to show a significant correlation between the expression of the multidrug resistant protein (P-gp and MRP1) and their functional activity in adult AML and paediatric ALL samples.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  4. Ooi BG, Sinniah M, Ismail S, Baharuddin R
    Malays J Pathol, 1996 Dec;18(2):89-93.
    PMID: 10879228
    The Serodia-HCV Particle Agglutination (HCV-PA) for the detection of HCV antibodies was compared with the Enzyme Immunoassay Test (UBI HCV EIA) for possible in-house use. A total of 150 specimens were analysed using UBI HCV EIA and Serodia-HCV PA. Of these, 80 (53.3%) were both PA and EIA positive and 59 (39.3%) were negative by both techniques. Eleven sera (7.4%) were found to be EIA-positive but PA-negative. These 11 discordant sera were further tested by the LiaTek-HCV III Immunoassay (Organon Teknika). Ten were found to be line immunoassay negative and one was line immunoassay positive. Failure of the PA to detect the HCV positive serum meant that a small proportion of HCV antibody positives may be missed by the PA test. We conclude that (i) EIA should continue to be the first line screening test in our laboratory, (ii) PA with its 100% specificity could be a useful supplementary screen for all EIA-positive sera and finally (iii) line immunoassay could be used on sera to resolve discordant results in the EIA and PA assays.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  5. Khairullah NS
    Malays J Pathol, 1996 Jun;18(1):27-30.
    PMID: 10879221
    Two different preparations of monoclonal antibodies developed against respiratory viruses have been evaluated by the immunofluorescence antibody technique. The Chemicon monoclonal antibodies were found to be more efficient at picking up positive specimens with a high sensitivity and specificity than Imagen monoclonal antibodies. However, the overall concordance rate of the monoclonal antibodies was 92.3%-100%. Generally, when compared with cell culture isolation, the immunofluorescence antibody technique was found to be more sensitive. The high quality of the Chemicon monoclonal antibodies contribute to their value in providing definitive diagnosis, within a few hours of specimen collection, thus allowing early management of patients, their contacts and control of hospital infection.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  6. Lam SK
    Malays J Pathol, 1993 Jun;15(1):9-12.
    PMID: 8277797
    Matched MeSH terms: Reagent Kits, Diagnostic
  7. Koay AS, Cheong YM
    Malays J Pathol, 1993 Jun;15(1):69-73.
    PMID: 8277794
    Forty-four serum samples of various reactivities to rickettsial antigens demonstrated by the indirect immunoperoxidase technique were tested with INDX Dip-S-Ticks (INDX Integrated Diagnostics Inc., USA) Kit for the detection of tick borne diseases. The kit utilised Rickettsia rickettsii the causative agent of Rocky Mountain spotted fever (RMSF) as antigens. The samples positive for endemic typhus were also tested against R. typhi, the agent for endemic typhus by the same method. The aim of this study was to determine the extent of cross-reactivity of R. rickettsii with rickettsial infections in Malaysia. Nine out of 12 tick typhus, 4 out of 10 scrub typhus and 4 out of 12 endemic typhus samples cross reacted with R. rickettsii. Ten out of 12 endemic samples were positive with R. typhi by the same method. From the study, we concluded that the INDX Dip-S-Ticks Kit can be used as a rapid screening test to detect endemic and tick-borne rickettsial infections in Malaysia but a second serological test is strongly recommended on all weakly reactive cases.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  8. Fang R, Sinniah M, Kuen LS
    Malays J Pathol, 1992 Dec;14(2):117-20.
    PMID: 1304624
    Dengue fever/Dengue haemorrhagic fever (DF/DHF) has been a public health problem in Malaysia with an endemic level of about 7 per 100,000 population per year. In 1990, Malaysia experienced its most severe outbreak of DF/DHF with a record total of 5,590 cases referred to the Division of Virology, Institute for Medical Research (IMR). Of these, 1,880 were confirmed serologically to be DF/DHF. The conventional serological procedure, the Haemagglutination Inhibition (HI) test, for the diagnosis of DF/DHF is cumbersome and causes delay in diagnosis. Another problem associated with the HI test has been that it has often been difficult to obtain a second convalescent serum sample for an accurate diagnosis. This has raised an urgent need to establish a "rapid" test for diagnosis of DF/DHF. As such the authors recently carried out an evaluation of a newly available commercial rapid test, namely, the Dengue Blot Assay (Diagnostic Biotechnology Singapore Pte Ltd). The test is intended for use in laboratory confirmation of dengue virus infection. The evaluation was to determine if the test could be utilised as a routine laboratory test and to establish its sensitivity and specificity. Over 400 samples were tested against the Dengue Blot Assay. Results were checked against an in-house Dengue IgM ELISA and HI assay. Preliminary results indicate that the sensitivity and specificity of the Dengue Blot is satisfactory. Our results also indicate that the Dengue Blot has a useful role to play in a routine laboratory especially since it provides rapid results on single serum samples thereby reducing the workload in a busy diagnostic laboratory.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  9. Wan Nazaimoon WM, Satgunasingam N, Khalid B
    Malays J Pathol, 1990 Jun;12(1):13-20.
    PMID: 2090885
    A simple and sensitive double-antibody radioimmunoassay for human growth hormone (HGH) was developed, optimised and validated. The anti-hGH sera raised in 2 rabbits were highly specific with low cross-reactions of 0.19% and 0.3% with human placental lactogen and 0.21% and 0.13% with human prolactin. The mean sensitivity of the assay determined from 28 assays was found to be 0.4 +/- 0.2 mIU/L. Mean recovery of added exogenous hGH was 98.8 +/- 6.8%. Linearity studies of samples diluted at 1:2, 1:4 and 1:8 gave values of 101.3 +/- 5.3%, 109.6 +/- 13.4% and 97.3 +/- 13% respectively of those expected. The reproducibility of the assay was good; within assay coefficient of variation for serum samples with GH concentrations of 2.7, 13.6 and 28.2 mU/l ranged from 5.1 to 8.3% while the inter-assay precision varied from 4.9 to 10.3%. The in-house assay showed good correlation (r = 0.96, p less than 0.001) with a commercial HGH RIA kit (Dainabot, Japan). A reference normal adult fasting GH level of less than 7 mIU/l was established from 95 samples assayed by this method.
    Matched MeSH terms: Reagent Kits, Diagnostic
  10. Situ SF, Ding CH, Nawi S, Johar A, Ramli R
    Malays J Pathol, 2017 Apr;39(1):25-31.
    PMID: 28413202 MyJurnal
    BACKGROUND: Chlamydia trachomatis and Neisseria gonorrhoeae are important bacterial pathogens of sexually transmitted infections (STIs) worldwide. This study sought to compare the analytical sensitivity and specificity of conventional methods against a rapid molecular method in detecting STIs caused by these bacteria.

    METHODS: Ninety five first-time male attendees of the Genito-urinary Medicine Clinic in Hospital Kuala Lumpur were included in this cross-sectional study. The detection of C. trachomatis was achieved through direct fluorescence antibody (DFA) staining of urethral swabs and real-time polymerase chain reaction testing (Xpert® CT/NG assay) on urine specimens. N. gonorrhoeae was detected through Gram staining and culture of urethral swabs and Xpert® CT/ NG assay on urine specimens.

    RESULTS: From the Xpert® CT/NG results, 11 (11.6%) attendees had chlamydia, 23 (24.2%) had gonorrhoea and 8 (8.4%) had both STIs. The sensitivity and specificity of DFA in detecting chlamydia compared to Xpert® CT/NG were 5.3% (95% CI: 0-28) and 94.7% (95% CI: 86-98), respectively. For gonorrhoea, the sensitivity and specificity of Gram staining were 90.3% (95% CI: 73-98) and 95.3% (86-99), respectively, whereas the sensitivity and specificity of culture compared to Xpert® CT/NG were 32.2% (95% CI: 17-51) and 100% (95% CI: 93-100), respectively.

    CONCLUSION: Although Gram-stained urethral swab smears are sensitive enough to be retained as a screening tool for gonorrhoea, culture as well as DFA lack sensitivity and are poorly suited to screen for gonorrhoea and chlamydia, respectively. However, owing to their high specificity, conventional detection methods are still suitable as confirmatory tests for gonorrhoea and chlamydia.

    Matched MeSH terms: Reagent Kits, Diagnostic
  11. Zainol Rashid Z, Othman SN, Abdul Samat MN, Ali UK, Wong KK
    Malays J Pathol, 2020 Apr;42(1):13-21.
    PMID: 32342927
    INTRODUCTION: The World Health Organization (WHO) declared COVID-19 outbreak as a world pandemic on 12th March 2020. Diagnosis of suspected cases is confirmed by nucleic acid assays with real-time PCR, using respiratory samples. Serology tests are comparatively easier to perform, but their utility may be limited by the performance and the fact that antibodies appear later during the disease course. We aimed to describe the performance data on serological assays for COVID-19.

    MATERIALS AND METHODS: A review of multiple reports and kit inserts on the diagnostic performance of rapid tests from various manufacturers that are commercially available were performed. Only preliminary data are available currently.

    RESULTS: From a total of nine rapid detection test (RDT) kits, three kits offer total antibody detection, while six kits offer combination SARS-CoV-2 IgM and IgG detection in two separate test lines. All kits are based on colloidal gold-labeled immunochromatography principle and one-step method with results obtained within 15 minutes, using whole blood, serum or plasma samples. The sensitivity for both IgM and IgG tests ranges between 72.7% and 100%, while specificity ranges between 98.7% to 100%. Two immunochromatography using nasopharyngeal or throat swab for detection of COVID-19 specific antigen are also reviewed.

    CONCLUSIONS: There is much to determine regarding the value of serological testing in COVID-19 diagnosis and monitoring. More comprehensive evaluations of their performance are rapidly underway. The use of serology methods requires appropriate interpretations of the results and understanding the strengths and limitations of such tests.

    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  12. Hamilton RG, Adkinson NF
    J Allergy Clin Immunol, 1998 Sep;102(3):482-90.
    PMID: 9768592
    BACKGROUND: No characterized diagnostic natural rubber latex skin testing material is licensed for use in the United States.

    OBJECTIVE: We have conducted a multicenter clinical skin testing study to document the safety and diagnostic sensitivity and specificity of a candidate Hevea brasiliensis nonammoniated latex (NAL) extract. These data are intended to support the licensing of this reagent for the diagnosis of latex allergy in high-risk populations.

    METHODS: Three hundred twenty-four subjects (304 adults and 20 children) were classified by their clinical history as having latex allergy (LA group, 124 adults and 10 children) or having no latex allergy (NLA group, 180 adults and 10 children). All subjects provided blood samples and then received sequential puncture skin tests (PSTs) at 1, 100, or 1000 microg/mL protein with a bifurcated needle and NAL (Greer Laboratories) from Malaysian Hevea brasiliensis (clone 600) sap. A 2-stage glove provocation test was used to clarify latex allergy status of individuals with positive history/negative PST result and negative history/positive PST result mismatches.

    RESULTS: Twenty-four subjects (15%) originally designated as having LA on the basis of their initial clinical history were reclassified to the NLA group on the basis of a negative glove provocation test result. Of the 134 subjects with LA, 54 (40%) were highly sensitive to latex, with a positive PST result at 1 microg/mL NAL. The Greer NAL reagent produced a positive PST rate (sensitivity) of 95% and 99% in subjects with LA at 100 microg/mL and 1 mg/mL, respectively. The negative PST rate (specificity) in 190 subjects with a negative history with the NAL extract at 100 microg/mL and 1 mg/mL, was 100% and 96%, respectively. Immediately after the PST, mild systemic reactions (mainly pruritus) were recorded in 16.1 % of the adults in the LA group and 4.4% of the adults in the NLA group. No reactions required treatment with epinephrine. Only mild delayed reactions were observed in 9.6% (LA group) and 2.8% (NLA group) of subjects 24 to 48 hours after PST. Mean wheal and erythema diameters measured in the 10 children in the LA group with spina bifida at 100 microg/mL and 1 mg/mL were similar to those observed in the adults in the LA group, suggesting that children are not at increased risk for systemic reactions compared with adults.

    CONCLUSIONS: A suggestive clinical history is necessary but not sufficient for a definitive diagnosis of IgE-dependent latex allergy. These data support the safety and diagnostic efficacy of the Greer NAL, skin test reagent at 100 micro/mL and 1 mg/mL for confirmatory PSTs.

    Matched MeSH terms: Reagent Kits, Diagnostic
  13. Wang SM, Sekaran SD
    Am J Trop Med Hyg, 2010 Sep;83(3):690-5.
    PMID: 20810840 DOI: 10.4269/ajtmh.2010.10-0117
    A commercial Dengue Duo rapid test kit was evaluated for early dengue diagnosis by detection of dengue virus NS1 antigen and immunoglobulin M (IgM)/IgG antibodies. A total of 420 patient serum samples were subjected to real-time reverse transcription-polymerase chain reaction (RT-PCR), in-house IgM capture enzyme-linked immunosorbent assay (ELISA), hemagglutination inhibition assay, and the SD Dengue Duo rapid test. Of the 320 dengue acute and convalescent sera, dengue infection was detected by either serology or RT-PCR in 300 samples (93.75%), as compared with 289 samples (90.31%) in the combined SD Duo NS1/IgM. The NS1 detection rate is inversely proportional, whereas the IgM detection rate is directly proportional to the presence of IgG antibodies. The sensitivity and specificity in diagnosing acute dengue infection in the SD Duo NS1/IgM were 88.65% and 98.75%, respectively. The assay is sensitive and highly specific. Detection of both NS1 and IgM by SD Duo gave comparable detection rate by either serology or RT-PCR.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  14. Bhutta ZA, Mansurali N
    Am J Trop Med Hyg, 1999 Oct;61(4):654-7.
    PMID: 10548305
    We evaluated the diagnostic sensitivity and specificity of two dot-enzyme-linked immunoassays (Typhidot and Typhidot-M; Malaysian Biodiagnostic Research SDN BHD, Kuala Lumpur, Malaysia), assessing IgG and IgM antibodies against the outer membrane protein (OMP) of Salmonella typhi, and the Widal test in comparison with blood culture in a consecutive group of children with suspected typhoid fever. Of 97 children with suspected typhoid fever, the disease was confirmed bacteriologically in 46 (47%), whereas 25 (26%) were considered to have typhoid fever on clinical grounds. An alternative diagnosis was made in 26 (27%). The Typhidot and Typhidot-M were superior to the Widal test in their diagnostic sensitivity and specificity, although values (sensitivity = 85-94% and specificity = 77-89%) were significantly lower than in other regional reports. The lower specificity of the Typhidot in our series may represent regional differences in the genomic structure and plasticity of the OMP of S. typhi and merits further evaluation of these tests in diverse geographic locations.
    Matched MeSH terms: Reagent Kits, Diagnostic
  15. Kelly DJ, Wong PW, Gan E, Chye CT, Cowan D, Lewis GE
    Am J Trop Med Hyg, 1990 Sep;43(3):301-7.
    PMID: 2121057
    Scrub typhus is a major cause of febrile illness throughout the Asia-Pacific region. It is commonly undiagnosed, partly because of the lack of a simple, reliable diagnostic test which can be used in clinical laboratories. The indirect immunoperoxidase technique, configured into a test kit, was provided to technicians who were trained in its use. They used the kit during a 2 year field trial in their respective clinical hospital laboratories throughout Malaysia. In an evaluation using 1,722 consecutive sera tested in those laboratories, the kit was found to have a median sensitivity for IgG detection of 0.85 (range 0.33-0.95), a median specificity of 0.94 (range 0.88-1.00), reproducibility of 0.86, and efficiency of 0.92 when compared to the reference laboratory. In a proficiency survey in which 10 laboratories received 3 coded test samples, all but 2 laboratories had results within 1 dilution of the reference laboratory in quantitating specific IgG, whereas 7 laboratories were within 1 dilution in quantitating IgM. The shelf life of the kit was at least 1 year at 4 degrees C.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  16. Yunus MH, Tan Farrizam SN, Abdul Karim IZ, Noordin R
    Am J Trop Med Hyg, 2018 Jan;98(1):32-38.
    PMID: 29141740 DOI: 10.4269/ajtmh.17-0632
    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara-positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
    Matched MeSH terms: Reagent Kits, Diagnostic
  17. Sekhar WY, Soo EH, Gopalakrishnan V, Devi S
    Singapore Med J, 2000 Aug;41(8):370-5.
    PMID: 11256343
    The aim of the study was to look into the epidemiology of serodiagnosed cases of leptospirosis at the University Hospital and compare two commercial ELISA Assays to the Microscopic Agglutination Test (MAT). Demographic data for all serodiagnosed cases for the years 1991-1997 were collected. From this data, 104 sera (n = 104) were selected as samples for comparative evaluation of the commercial ELISAs (INDX Dip-S-Ticks and PanBio ELISA) to the MAT test. Thirty two (n = 32) negative control sera were selected from serodiagnosed cases of other differential diagnosis of leptospira infection. The MAT test is a standard test that detects agglutination antibodies to leptospira biflexa, while the INDX Dip-S-Ticks is an ELISA dot test assaying for total anti-leptospira antibodies. The PanBio ELISA is a colorometric assay in test well strips to detect anti-leptospira IgM. The sensitivity, specificity, and efficiency of tests were calculated at a MAT cut-off value of 1:320. Demographic data showed that leptospirosis peaks during March-May and Aug-Nov coinciding with the inter-monsoon period with more men being infected than women and more adults than children. The sensitivity, specificity, and efficiency of test for the INDX Dip-S-Ticks were 83.3%, 93.8% and 87.5% while the values for the PanBio ELISA were 54.2%, 96.9% and 71.3%. The suboptimal PanBio result could be related to the blocking effect of high IgG titres or could be related to the diagnostic MAT cut-off values used in this study. The data hence reflects a pattern of transmission that is related to "wet" occupational risk factors. The commercial assays evaluated, are easier to perform but interpretation of results should be based on level of endemicity. The INDX Dip-S-Ticks allows this flexibility and is a practical alternative to the MAT test.
    Matched MeSH terms: Reagent Kits, Diagnostic/standards*
  18. Wu LL, Sazali BS, Adeeb N, Khalid BA
    Singapore Med J, 1999 Jan;40(1):23-6.
    PMID: 10361481
    Clinical diagnosis of congenital hypothyroidism (CH) is difficult at birth without neonatal screening. In line with the priorities of the national health services in Malaysia towards preventive medicine, early diagnosis and treatment of CH is emphasised. We conducted a pilot study at Kuala Lumpur's Maternity Hospital between April 1995 and November 1995 to estimate the incidence of CH and also evaluated the problems associated with large-scale neonatal screening using a commercial TSH kit on cord bloodspots.
    Matched MeSH terms: Reagent Kits, Diagnostic
  19. Thevarajah MT, Nadarajah S, Chew YY, Chan PC
    Singapore Med J, 2008 Jun;49(6):454-7.
    PMID: 18581016
    We report the results of a laboratory evaluation of the BioRad Urinary Metanephrines Reagent Kit. The test was designed for the quantitative measurement of normetanephrine and metanephrine in urine by high performance liquid chromatography. The kit was evaluated in view of improving assay reliability and specificity as compared to the manual method based on cation exchange chromatography and spectrophotometry.
    Matched MeSH terms: Reagent Kits, Diagnostic*
  20. Kumarasamy V, Chua SK, Hassan Z, Wahab AH, Chem YK, Mohamad M, et al.
    Singapore Med J, 2007 Jul;48(7):669-73.
    PMID: 17609831
    INTRODUCTION: The aim of this report is to establish an accurate diagnosis of acute dengue virus infection early, in order to provide timely information for the management of patients and early public health control of dengue outbreak.
    METHODS: 224 serum samples from patients with a clinical diagnosis of acute dengue infection, which were subsequently confirmed by laboratory tests, were used to evaluate the performance of a commercially-available dengue NS1 antigen-capture ELISA kit.
    RESULTS: The dengue NS1 antigen-capture ELISA gave an overall sensitivity rate of 93.3 percent (209/224). The sensitivity rate was significantly higher in acute primary dengue (97.4 percent) than in acute secondary dengue (68.8 percent). In comparison, the virus isolation gave an overall positive isolation rate of 64.7 percent, with a positive rate of 70.8 percent and 28.1 percent, for acute primary dengue and acute secondary dengue, respectively. Molecular detection of dengue RNA by RT-PCR gave an overall positive detection rate of 63.4 percent, with a positive rate of 62.5 percent and 68.8 percent, for acute primary dengue and acute secondary dengue, respectively. Of the 224 acute serum samples from patients with laboratory-confirmed acute dengue infection, dengue IgM was detected in 88 specimens, comprising 68 acute primary dengue specimens and 20 acute secondary dengue specimens. NS1 antigen-capture ELISA kit gave an overall sensitivity rate of 88.6 percent in the presence of anti-dengue IgM and 96.3 percent in the absence of anti-dengue IgM.
    CONCLUSION: Of the 224 acute serum samples, the sample ages of 166 acute serum samples are known. The positive detection rate of dengue NS1 antigen-capture ELISA, on the whole, was higher than the other three established diagnostic test methods for laboratory diagnosis of acute dengue infection.
    Matched MeSH terms: Reagent Kits, Diagnostic
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links