Displaying publications 21 - 31 of 31 in total

Abstract:
Sort:
  1. Gholizadeh H, Abu Osman NA, Kamyab M, Eshraghi A, Lúvíksdóttir AG, Wan Abas WA
    Am J Phys Med Rehabil, 2012 Oct;91(10):894-8.
    PMID: 22173083
    The effects of Seal-In X5 and Dermo liner (Össur) on suspension and patient's comfort in lower limb amputees are unclear. In this report, we consider the case of a 51-yr-old woman with bilateral transtibial amputation whose lower limbs were amputated because of peripheral vascular disease. The subject had bony and painful residual limbs, especially at the distal ends. Two prostheses that used Seal-In X5 liners and a pair of prostheses with Dermo liners were fabricated, and the subject wore each for a period of 2 wks. Once the 2 wks had passed, the pistoning within the socket was assessed and the patient was questioned as to her satisfaction with both liners. This study revealed that Seal-In X5 liner decreased the residual limb pain experienced by the patient and that 1-2 mm less pistoning occurred within the socket compared with the Dermo liner. However, the patient needed to put in extra effort for donning and doffing the prosthesis. Despite this, it is clear that the Seal-In X5 liner offers a viable alternative for individuals with transtibial amputations who do not have enough soft tissue around the bone, especially at the end of the residual limb.
    Matched MeSH terms: Tibia/surgery*
  2. Abu Osman NA, Spence WD, Solomonidis SE, Paul JP, Weir AM
    Med Eng Phys, 2010 Sep;32(7):760-5.
    PMID: 20678997 DOI: 10.1016/j.medengphy.2010.04.020
    The purpose of this investigation was to vary the load on the patellar tendon bar and to study the subsequent effect this has on the pattern of the pressure distribution at the stump-socket interface. Ten male subjects from the Southern General Hospital in Glasgow, UK participated in this study. Measuring systems utilising strain gauge and electrohydraulic technologies were designed, developed and constructed to enable pressure measurements to be conducted. One transducer, the patellar tendon (PT) transducer, was attached to the patellar tendon bar of the socket such that the patellar tendon bar was capable of being translated by +/-10 mm towards or away from the tendon. The results of this study showed that the position of the patellar tendon bar had no significant effect on the pressure distribution around the socket indicating that it is an unnecessary feature, which, we propose, may be eliminated during manufacture of a trans-tibial socket.
    Matched MeSH terms: Tibia/surgery*
  3. Saravanan S, Vivek AS
    Med J Malaysia, 2007 Dec;62(5):418-9.
    PMID: 18705481 MyJurnal
    This is to report on the use of growing endoprosthesis, also known as lengthening prosthesis in the management of four patients in the paedriatic age group in the Orthopaedic Oncolgy Unit at University Malaya Medical Centre. These are custom made prosthesis, designed and made in India based on measured roentrograms. The ages of these patients vary from 6 to 13 years old. These are cases of Osteosarcoma and Ewing's sarcoma around the knee. This is the first time these custom made prosthesis have ever been used in Malaysia. We feel that this is a feasible option for limb salvage in the treatment of primary bone tumours in growing children.
    Matched MeSH terms: Tibia/surgery*
  4. Sulaiman AR, Munajat I, Liau KM, Salehuddin AY, Shukrimi A
    Med J Malaysia, 2006 Dec;61 Suppl B:48-50.
    PMID: 17600992
    Distraction osteogeneis over intramedullary nail has a benefit of decreasing the time for external fixation thus reducing the rate of associated complications. However, risk of panosteomyelitis is still the major worry. We are reporting two patients who underwent the procedure. The first case was a 13-year-old girl requiring 6 cm of femoral lengthening and the second case was a 17-year-old girl who required 5 cm of tibial lengthening. The healing index was 19.5 days/cm and 14.8 days/cm respectively, compared favorably to 30 days/cm with traditional method of distraction osteogenesis. There were mild pin tract infections and joint stiffness which responded to non-operative treatment.
    Matched MeSH terms: Tibia/surgery*
  5. Sulaiman AR, Nordin S, Faisham WI, Zulmi W, Halim AS
    J Orthop Surg (Hong Kong), 2006 Apr;14(1):64-6.
    PMID: 16598090
    Resection and reconstruction using a vascularised fibular graft is a viable alternative treatment for congenital pseudarthrosis of the tibia, although distal junctional nonunion and residual deformity are known complications that are difficult to treat. We illustrate 2 cases in which bony union was achieved following a technique using fibular grafting and intramedullary nailing, without additional bone grafting. This technique was feasible because of hypertrophy of the fibular graft.
    Matched MeSH terms: Tibia/surgery*
  6. Kwan MK, Penafort R, Saw A
    Med J Malaysia, 2004 Dec;59 Suppl F:39-41.
    PMID: 15941159
    Joint stiffness is one of the complications of limb procedure. It developes as a result of failure of knee flexors to lengthen in tandem with the bone, especially when there is inadequate physical therapy to provide active and passive mobilization of the affected joint. We are reporting four patients who developed fixed flexion contracture of their knees during bone lengthening procedure for the tibia with Ilizarov external fixator. Three of them were treated for congenital pseudoarthrosis and one was for fibular hemimelia. None of them were able to visit the physiotherapist even on a weekly basis. A splint was constructed from components of Ilizarov external fixator and applied on to the existing frame to passively extend the affected knee. Patients and their family members were taught to perform this exercise regularly and eventually near complete correction were achieved. With this result, we would like to recommend the use of this "Passive Knee Extension Splint" to avoid knee flexion Contracture during limb lengthening procedures with Ilizarov external fixators.
    Matched MeSH terms: Tibia/surgery*
  7. Imran Y, Zulmi W, Halim AS
    Med J Malaysia, 2004 Dec;59 Suppl F:35-8.
    PMID: 15941158
    Long bone reconstruction using vascularized fibula graft is becoming more popular despite the difficulties and its post-operative complications. We reviewed our early experience dealing with vascularized fibula graft for the management of massive long bone defect. Thirteen patients had undergone long bone reconstruction using vascularized fibula graft. Early complications that had been encountered include superficial wound infection (23%), transient common peroneal nerve palsy (23%), stage 1 bed sore (7.7%), anastomotic venous thrombosis (30.8%), DIVC (15.4%), flap loss and amputation (7.7%), and reactive psychiatric problem (7.7%). The early complications following this procedure are comparable with other major orthopaedic surgery and most of them are minor and treatable. The complication rates are also comparable with similar surgery done elsewhere.
    Matched MeSH terms: Tibia/surgery
  8. Khadijah K, Mashita M, Saidu MF, Fazilah F, Khalid KA
    Med J Malaysia, 2004 May;59 Suppl B:123-4.
    PMID: 15468849
    This study is to qualitatively evaluate a locally produced hydroxyapatite (HA), made by AMREC-SIRIM in an experimental animal bone defect using New Zealand White (NZW) rabbits. HA cylindrical blocks measuring 2.5 mm (D) x 1.0 mm (H) were implanted in the rabbits' left tibia. The tibias were harvested within one to three weeks post-implantation. The implantion site was cut into thin undecalcified sections of about 30 microm to 60 microm and stained with Toluidine Blue and Goldner's Masson Trichrome. Microscopic examinations using standard light microscopy of these slides were performed.
    Matched MeSH terms: Tibia/surgery
  9. Najafpour HD, Suzina AH, Nizam A, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:121-2.
    PMID: 15468848
    There was a significant increased in Absolute Contact Length measurements of endosteal bone growth along the Nickel-Titanium (NiTi) implant coated with the natural coral powder and Hydroxyapatite (HA) compared to the non-calcium coated implants. This study demonstrated that coated implants seemed to show earlier and higher osseointergration phenomena compared to non coated ones. Furthermore, there was significantly greater bone-to-implant contact at the apical 1/3rd of the coated implants.
    Matched MeSH terms: Tibia/surgery
  10. Pan KL, Mourougayah V, Jayamalar T
    Med J Malaysia, 2003 Dec;58(5):783-5.
    PMID: 15190672
    We present an elderly patient with a squamous cell carcinoma over the subcutaneous aspect of the leg involving the tibia. En bloc resection of the tumour together with a 10 centimetre segment of the tibia was done. The resected bone was autoclaved, replaced in its original position and stabilized with bone cement and a locked nail. This allowed early ambulation with minimal cost.
    Matched MeSH terms: Tibia/surgery*
  11. Devgan A, Marya KM, Kundu ZS, Sangwan SS, Siwach RC
    Med J Malaysia, 2003 Mar;58(1):62-8.
    PMID: 14556327
    To retrospectively study the long term results of high tibial valgus osteotomy in management of primary medial compartment osteoarthritis, with special reference to patient satisfaction and functional assessment, we conducted this study in radiologically established 50 knees of patients with primary osteoarthrosis of knee. In these patients with medial compartment disease (varus knee), medial open wedge osteotomy was performed using full thickness iliac crest grafts. These were called for follow-up after average 7.5 years and clinico-radiological assessment was done. Although many surgeons of the west do not favour this osteotomy, we found the procedure to be quite acceptable to our patients in whom the primary concerns of cost and squatting habits are well taken care of. The authors feel that this osteotomy is still relevant in the third world. Results do deteriorate with time but most patients consider the surgery satisfactory.
    Matched MeSH terms: Tibia/surgery*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links