Displaying publications 21 - 26 of 26 in total

Abstract:
Sort:
  1. Munajat M, Mohd Nordin NA, Mohamad Yahya NH, Zulkifly AH
    Medicine (Baltimore), 2019 Sep;98(36):e17045.
    PMID: 31490397 DOI: 10.1097/MD.0000000000017045
    INTRODUCTION: The presence of significant pain and swelling during the acute stage following total knee arthroplasty (TKA) may limit the patients' ability to cooperate in intensive physiotherapy interventions. Low-intensity pulsed ultrasound is one of the modalities that can be used for acute pain and swelling management. However, only one study investigated the effect of this modality in patients with TKA. There is limited documentation of the effects of combining low-intensity pulsed ultrasound in TKA rehabilitation in the recovery of physical impairments and how these influence the recovery of function after TKA. Therefore, this study is proposed with the aim to evaluate the effects of low-intensity pulsed ultrasound as an adjunct to conventional physiotherapy on the recovery of physical impairments, functional performance and quality of life after TKA surgery.

    METHODS: This is an assessor-blinded quasi-experimental study comparing two approaches of physiotherapy, namely pulsed ultrasound-added physiotherapy and conventional physiotherapy. Total number of participants with TKA required for this study will be calculated based on the result of a pilot study. Participants will be alternately allocated into either pulsed ultrasound-added physiotherapy group (low-intensity pulsed ultrasound and conventional physiotherapy) or control group (conventional physiotherapy). Pulsed ultrasound-added physiotherapy group will receive low-intensity pulsed ultrasound starting at post-operative day 2 (4-5 times for the first-week after surgery and 2-3 times a week for a further 2 weeks). Both groups will receive conventional physiotherapy 4 to 5 times for the first-week after surgery and 2 to 3 times a week for a further 11 weeks. This procedure and process will be tested and established in a pilot study. Primary outcomes of interest are pain level, swelling, active range of knee motion, and quadriceps strength. The secondary outcomes are functional performance and quality of life.

    DISCUSSION: This study will fill the gaps in knowledge relating the benefits of including low-intensity pulsed ultrasound into conventional physiotherapy for patients with TKA.

    TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry, ACTRN12618001226291.

    Matched MeSH terms: Ultrasonic Waves*
  2. Qamruddin I, Alam MK, Mahroof V, Karim M, Fida M, Khamis MF, et al.
    Pain Res Manag, 2021;2021:6624723.
    PMID: 34035871 DOI: 10.1155/2021/6624723
    Objective: Low-intensity pulsed ultrasound (LIPUS) is a noninvasive modality to stimulate bone remodeling (BR) and the healing of hard and soft tissues. This research evaluates the biostimulatory effect of LIPUS on the rate of orthodontic tooth movement (OTM) and associated pain, when applied at 3-week intervals.

    Methods: Twenty-two patients (11 males and 11 females; mean age 19.18 ± 2.00 years) having Angle's Class II division 1 malocclusion needing bilateral extractions of maxillary first bicuspids were recruited for this split-mouth randomized clinical trial. After the initial stage of alignment and leveling with contemporary edgewise MBT (McLaughlin-Bennett-Trevisi) prescription brackets (Ortho Organizers, Carlsbad, Calif) of 22 mil, followed by extractions of premolars bilaterally, 6 mm nickel-titanium spring was used to retract the canines separately by applying 150 g force on 0.019 × 0.025-in stainless steel working archwires. LIPUS (1.1 MHz frequency and 30 mW/cm2 intensity output) was applied for 20 minutes extraorally and reapplied after 3 weeks for 2 more successive visits over the root of maxillary canine on the experimental side whereas the other side was placebo. A numerical rating scale- (NRS-) based questionnaire was given to the patients on each visit to record their weekly pain experience. Impressions were also made at each visit before the application of LIPUS (T1, T2, and T3). Models were scanned with a CAD/CAM scanner (Planmeca, Helsinki, Finland). Mann-Whitney U test was applied for comparison of canine movement and pain intensity between both the groups.

    Results: No significant difference in the rate of canine movement was found among the experimental (0.90 mm ± 0.33 mm) and placebo groups (0.81 mm ± 0.32 mm). There was no difference in pain reduction between experimental and placebo groups (p > 0.05).

    Conclusion: Single-dose application of LIPUS at 3-week intervals is ineffective in stimulating the OTM and reducing associated treatment pain.

    Matched MeSH terms: Ultrasonic Waves/adverse effects*
  3. Sergeev A, Motyakin M, Barashkova I, Zaborova V, Krasulya O, Yusof NSM
    Ultrason Sonochem, 2021 Sep;77:105673.
    PMID: 34311321 DOI: 10.1016/j.ultsonch.2021.105673
    The effect of ultrasound treatment on molecular mobility and organization of the main components in raw goat milk was studied by EPR and NMR spectroscopies. NMR relaxation studies showed an increase in the spin-lattice T1 and spin-spin T2 relaxation times in goat milk products (cream, anhydrous fat) and change in the diffusion of proton-containing molecules during ultrasound treatment. The diffusion became more uniform and could be rather accurately approximated by one effective diffusion coefficient Deff, which indicates homogenization of goat milk components, dispersion of globular and supermicellar formations under sonication. EPR studies have shown that molecular mobility and organization of hydrophobic regions in goat milk are similar to those observed in micellar formations of surfactants with a hydrocarbon chain length C12-C16. Ultrasound treatment did not affect submicellar and protein globule organization. Free radicals arising under ultrasound impact of milk reacted quickly with components of goat milk (triglycerides, proteins, fatty acids) and were not observed by spin trapping method.
    Matched MeSH terms: Ultrasonic Waves*
  4. Shahinuzzaman M, Akhtar P, Amin N, Ahmed Y, Anuar FH, Misran H, et al.
    Sci Rep, 2021 Jun 14;11(1):12503.
    PMID: 34127747 DOI: 10.1038/s41598-021-91913-w
    In this study, the extraction conditions extracted maximize amounts of phenolic and bioactive compounds from the fruit extract of Ficus auriculata by using optimized response surface methodology. The antioxidant capacity was evaluated through the assay of radical scavenging ability on DPPH and ABTS as well as reducing power assays on total phenolic content (TPC). For the extraction purpose, the ultrasonic assisted extraction technique was employed. A second-order polynomial model satisfactorily fitted to the experimental findings concerning antioxidant activity (R2 = 0.968, P 
    Matched MeSH terms: Ultrasonic Waves
  5. Tahmasebi-Boldaji R, Hatamipour MS, Khanahmadi M, Sadeh P, Najafipour I
    Ultrason Sonochem, 2019 Oct;57:89-97.
    PMID: 31208622 DOI: 10.1016/j.ultsonch.2019.05.018
    This paper presents the successful application of ultrasound-assisted packed-bed (UAE-PB) method for the extraction of hypericin from the Hypericum perfuratum L. The Soxhlet system was utilized for the determination of suitable solvent from ethanol, methanol or from the mixture of different proportions of ethanol-methanol. The mixture of 50:50 v/v ethanol-methanol was obtained to be the most suitable solvent since it led to the highest extraction amount of hypericin. The extraction amount of hypericin increased by 13.6% and 21.4% when the solvent changed from pure methanol to the mixture of 50:50 v/v ethanol-methanol for the extraction time of 3 and 8 h, respectively. Subsequently, the extraction was conducted through the UAE-PB, and the effects of temperature, time, and the ratio of solvent to the dried plant were studied. The response surface method (RSM) was used to investigate the effect of parameters on the extraction in the UAE-PB system. At the temperature of 60 °C, extraction time of 105 min, and the solvent to plant ratio of 15.3, the maximum extraction yield of hypericin was achieved. In the optimal conditions, the amount of extraction was 0.112 mg hypericin/g dried plant, which was in accordance with the optimized predicted value (0.111 mg hypericin/g dried plant) from Design-Expert software.
    Matched MeSH terms: Ultrasonic Waves*
  6. Tao Y, Li D, Siong Chai W, Show PL, Yang X, Manickam S, et al.
    Ultrason Sonochem, 2021 Apr;72:105410.
    PMID: 33341708 DOI: 10.1016/j.ultsonch.2020.105410
    This study aimed at investigating the performances of air drying of blackberries assisted by airborne ultrasound and contact ultrasound. The drying experiments were conducted in a self-designed dryer coupled with a 20-kHz ultrasound probe. A numerical model for unsteady heat and mass transfer considering temperature dependent diffusivity, shrinkage pattern and input ultrasonic energies were applied to explore the drying mechanism, while the energy consumption and quality were analyzed experimentally. Generally, both airborne ultrasound and contact ultrasound accelerated the drying process, reduced the energy consumption and enhanced the retentions of blackberry anthocyanins and organic acids in comparison to air drying alone. At the same input ultrasound intensity level, blackberries received more ultrasound energies under contact sonication (0.299 W) than airborne sonication (0.245 W), thus avoiding the attenuation of ultrasonic energies by air. The modeling results revealed that contact ultrasound was more capable than airborne ultrasound to intensify the inner moisture diffusion and heat conduction, as well as surface exchange of heat and moisture with air. During air drying, contact ultrasound treatment eliminated the gradients of temperature and moisture inside blackberry easier than airborne ultrasound, leading to more homogenous distributions. Moreover, the total energy consumption under air drying with contact ultrasound assistance was 27.0% lower than that with airborne ultrasound assistance. Besides, blackberries dehydrated by contact ultrasound contained more anthocyanins and organic acids than those dried by airborne ultrasound, implying a higher quality. Overall, direct contact sonication can well benefit blackberry drying in both energy and quality aspects.
    Matched MeSH terms: Ultrasonic Waves*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links