METHODS: This was a cross-sectional study involving 195 women, participants of the Dunedin arm of the ProLong study (PROlapse and incontinence LONG-term research study) seen 20 years after their index birth. Assessment included a standardized questionnaire, ICS POP-Q and 4D translabial ultrasound. Post-imaging analysis of LAM and EAS integrity was undertaken blinded against other data. Statistical analysis was performed using Fisher's exact test and results were expressed as odds ratios (OR).
RESULTS: LAM avulsion and EAS defects were diagnosed in 31 (16%) and 24 (12.4%) women respectively. No significant difference in the prevalence of levator avulsion and EAS defects between primiparous (VP1) and multiparous (VP2+) women who had delivered vaginally (OR 1.9, 95% CI 0.72-5.01, p = 0.26) and (OR 1.2, 95% CI 0.4-3.8, p = 0.76) respectively.
CONCLUSIONS: Most LAM avulsions and EAS defects seem to be caused by the first vaginal birth. Subsequent vaginal deliveries after the first were unlikely to cause further LAM trauma.
METHODS: A qualitative phenomenological approach with in-depth interview method was conducted in two tertiary hospitals in Kelantan, Malaysia. All women admitted to labour room, obstetrics and gynaecology wards and intensive care units in 2014 were screened for the presence of any vital organ dysfunction or failure based on the World Health Organization criteria for maternal near miss. Pregnancy irrespective of the gestational age was included. Women younger than 18 years old, with psychiatric disorder and beyond 42 days of childbirth were excluded.
RESULTS: Thirty women who had experienced maternal near miss events were included in the analysis. All were Malays between the ages of 22 and 45. Almost all women (93.3%) had secondary and tertiary education and 63.3% were employed. The women's perceptions of the quality of their care were influenced by the competency and promptness in the provision of care, interpersonal communication, information-sharing and the quality of physical resources. The predisposition to seek healthcare was influenced by costs, self-attitude and beliefs.
CONCLUSIONS: Self-appraisal of maternal near miss, their perception of the quality of care, their predisposition to seek healthcare and the social support received were the four major themes that emerged from the experiences and perceptions of women with maternal near miss. The women with maternal near miss viewed their experiences as frightening and that they experienced other negative emotions and a sense of imminent death. The factors influencing women's perceptions of quality of care should be of concern to those seeking to improve services at healthcare facilities. The addition of a maternal near miss case review programme, allows for understanding on the factors related to providing care or to the predisposition to seek care; if addressed, may improve future healthcare and patient outcomes.
AIMS: Our objective was to investigate long-term association between delivery mode, LAM avulsion and obstetric anal sphincter injuries (OASIS) in women at least 20 years after their first birth.
METHODS: All women recruited at 'index birth' of the Dunedin (New Zealand) arm of ProLong (PROlapse and incontinence LONG-term research) Study, were invited to have translabial and transperineal ultrasound assessment of LAM and anal sphincters. Post-processing analysis of imaging data was performed blinded against delivery data. Statistical analysis was performed using the χ2 test and results are expressed as odds ratios (OR).
RESULTS: Of the initial 1250 participants, 196 women returned for examination. Mean age was 50.8 years with a mean body mass index of 27.6 and median parity was three. They were seen on average 23 years after their first delivery. Four data sets were unavailable and one declined ultrasound assessment, leaving 191 for analysis. LAM avulsion was diagnosed in 29 (15.2%), and 24 women (12.6%) had significant anal sphincter defect. LAM avulsion was associated with forceps delivery (OR 2.45, 95% CI 1.04-5.80, P = 0.041). Forceps conveyed a greater risk of OASIS (21%) compared to a spontaneous vaginal delivery (11%) but did not reach statistical significance.
CONCLUSIONS: Forceps delivery is associated with long-term injurious effect on pelvic floor structures. Discussions of the long-term negative impact of pelvic floor structures and their functions are necessary to achieve an informed consent toward an operative vaginal delivery.
AIMS: This study aimed to assess the pelvic floor ultrasound characteristics of Ugandan women suffering with obstetric fistula, unrepaired fourth degree obstetric tears and pelvic organ prolapse, and determine whether obstructed labour resulting in obstetric fistula causes more levator muscle defects compared to parous women without a history of obstructed labour.
MATERIALS AND METHODS: This was a prospective study in western Uganda assessing 82 women with obstetric fistula, unrepaired fourth degree obstetric tears and pelvic organ prolapse with a pelvic floor ultrasound scan.
RESULTS: Demographic characteristics were significantly different, with women suffering pelvic organ prolapse being older and more parous. Hiatal area on Valsalva was significantly smaller in the obstetric fistula group (mean 21.45 cm2 ) compared to non-obstetric fistula group (unrepaired fourth degree obstetric tears and pelvic organ prolapse; mean 30.44 cm2 ); a mean difference of 9.0 cm2 (95% CI: 5.4-12.6 cm2 , P