Displaying publications 21 - 22 of 22 in total

Abstract:
Sort:
  1. Tan NH, Fung SY, Yap YH
    PMID: 21983189 DOI: 10.1016/j.cbpb.2011.09.009
    A thrombin-like enzyme (termed albolabrase) was isolated in purified form from the venom of Cryptelytrops albolabris (white-lipped tree viper) using high performance anion ion exchange and gel filtration chromatography. The molecular mass of albolabrase was 33.7 kDa as determined by SDS-PAGE and 35.8 kDa as determined by Superose gel filtration chromatography. The N-terminal sequence was determined to be VVGGDECNINE which is homologous to many snake venom thrombin-like enzymes. Albolabrase exhibits both arginine ester hydrolase and arginine amidase activities and the enzyme is fastidious towards tripeptide chromogenic anilide substrates. The fibrinogen clotting activity was optimum at 3mg/mL bovine fibrinogen, and showed distinct species differences in the following decreasing order: bovine fibrinogen>dog fibrinogen≈human fibrinogen>goat fibrinogen. The enzyme failed to clot both rabbit and cat fibrinogens. Reversed-phase HPLC analysis on the breakdown products of fibrinogenolytic action of albolabrase indicated that the enzyme belongs to the AB class of snake venom thrombin-like enzyme. In the indirect ELISA, IgG anti-albolabrase reacted extensively with most crotalid venoms, except with Tropidolaemus wagleri and Calloselasma rhodostoma venoms. The double sandwich ELISA, however, showed that anti-albolabrase reacted strongly only with venoms from the Trimeresurus complex, and that the results support the proposed new taxonomy changes concerning the Trimeresurus complex.
    Matched MeSH terms: Viper Venoms/enzymology*
  2. Baig MA, Swamy KB
    Indian J Pathol Microbiol, 2021 1 13;64(1):123-127.
    PMID: 33433421 DOI: 10.4103/IJPM.IJPM_900_19
    Background: In the laboratory, factor VIII can be measured by three different methodologies, such as one-stage clotting assay, two-stage clotting assay, and chromogenic assay. These assays differ in ease of use, variety of reagents available, sensitivity to mild hemophilia A, and interference from lupus anticoagulants (LACs). Certain factor VIII gene mutations can cause discrepancy in results between one-stage activated partial thromboplastin time (APTT) and chromogenic assays.

    Materials and Methods: The coagulometer for factor VIII assay is Sysmex CS-5100. All data were expressed as mean ± standard deviation (SD).

    Results: A total of 135 cases were studied. Of these, 100 cases were of mild hemophilia A diagnosed by molecular genetics and, 15 cases were positive for LAC, which were confirmed by dilute Russell Viper venom test. Clot-based one-stage APTT assay showed 65% sensitivity and 80% specificity in diagnosing mild hemophilia A cases and out of 15 LAC cases, it showed false positivity in five cases. Chromogenic assay showed 85% sensitivity and 90% specificity in diagnosing mild hemophilia cases and was 100% specific in excluding LAC cases.

    Conclusions: One-stage APTT assay is the most commonly used test for determining factor VIII levels but chromogenic assay are considered as the gold standard and recommended as the reference method by European Pharmacopoeia and ISTH subcommittee. Mild hemophilia A patients with missense mutations show discrepancy between the one-stage clot-based APTT assay and chromogenic assays for determination of factor VIII level and this can lead to misdiagnosis or misclassification of mild hemophilia A. Therefore, it is recommended that both the assays should be used in the evaluation of mild hemophilia cases.

    Matched MeSH terms: Viper Venoms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links