Displaying publications 41 - 44 of 44 in total

Abstract:
Sort:
  1. Lim TW, Abuzaid MM, Muhammad Zulhisham MFAH, Muhamad Hanafiah NN, Mohd Zahari HL, Mahmud M, et al.
    J Dent, 2025 Mar;154:105585.
    PMID: 39828021 DOI: 10.1016/j.jdent.2025.105585
    OBJECTIVE: The present study aimed to investigate the impact of utilizing an innovative and comprehensive patient-centered digital clinical decision aid designed to facilitate shared decision-making in missing tooth replacement between dental students and their patients.

    METHODS: A qualitative study using interview approach was conducted in Hong Kong SAR and Malaysia. Thirty dental undergraduate students, each with one patient from the Faculty of Dentistry at The University of Hong Kong (n = 15) and Universiti Teknologi MARA (n = 15), were introduced to a digitally designed decision aid in missing tooth replacement prior to their treatment appointments. Semi-structured interviews were conducted with each student and patient, adhering to the interview protocol. Each interview was audio-recorded, transcribed, and subsequently coded to investigate the perceptions and potential advantages of this decision aid.

    RESULTS: Thematic analysis identified three key themes from the dental students' perspective: communication, utilization, and satisfaction. From patients' perceptions, four central themes emerged: communication, treatment information, uncertainty, and utilization. Detailed examination of the data highlighted an enhancement in patients' confidence and trust in their dental care providers, as well as a marked increase in both student and patient satisfaction levels upon implementing this novel approach. The average satisfaction rates for students were 83 % for Hong Kong SAR and 82 % for Malaysia.

    CONCLUSION: This patient-centered clinical decision aid helped to enhance communication between dental students and patients in both regions, ultimately leading to heightened patient satisfaction levels. Nonetheless, to address the present study's limitations, future studies should consider diversifying participant backgrounds, including patients without prior treatment discussions with students.

    CLINICAL SIGNIFICANCE: Clinical decision aids are valuable tools in clinical teaching due to their enhancement of communication between clinicians and patients. They promote shared decision-making, leading to more personalized and evidence-driven treatment plans, ultimately improving patient care.

  2. Mustafa NWNA, Ahmad R, Ahmad Khushaini MA, Kamar Affendi NH, Ab Ghani SM, Tan SK, et al.
    ACS Biomater Sci Eng, 2024 Jan 08;10(1):405-419.
    PMID: 38040671 DOI: 10.1021/acsbiomaterials.3c01551
    This study assessed the corrosion resistance, intracutaneous reactivity, acute systemic toxicity, and in situ tissue effect of the implantation of porous NiTi fabricated by metal injection molding in animal models. For the intracutaneous reactivity study, five intracutaneous injections were administered per site with and without the tested extract in polar and nonpolar solutions. The extract was also delivered via intravenous and intraperitoneal routes for acute systemic toxicity. TiAl6 V4 (control) and porous NiTi were implanted in rabbit femora for a period of 13 weeks to evaluate the in situ tissue response. Corrosion was evaluated through open and cyclic polarization in PBS, while biocompatibility was investigated by assessing the general conditions, skin irritation score (edema and erythema), and histopathology. No active dissolution or hysteresis loop was observed in the corrosion study. None of the animals exhibited death, moribundity, impending death, severe pain, self-mutilation, or overgrooming. No edema was observed at injection sites. Only the positive control showed an erythematous reaction at 24, 48, and 72 h observations (p < 0.001). Porous NiTi showed a low in situ biological response for inflammation, neovascularization, and fibrosis in comparison to the control implant (p = 0.247, 0.005, and 0.011, respectively). Porous NiTi also demonstrated high pitting corrosion resistance while causing no acute hypersensitivity or acute systemic toxicity. The study concludes that porous NiTi implants were unlikely to cause local sensitization, acute systemic toxicity, or chronic inflammatory reactions in an animal model. Porous NiTi also exhibited osseointegration equivalent to Ti6AI4 V of known biocompatibility.
  3. Chan NY, Orchard J, Agbayani MJ, Boddington D, Chao TF, Johar S, et al.
    J Arrhythm, 2022 Feb;38(1):31-49.
    PMID: 35222749 DOI: 10.1002/joa3.12669
    In this paper, the Asia Pacific Heart Rhythm Society (APHRS) sought to provide practice guidance on AF screening based on recent evidence, with specific considerations relevant to the Asia-Pacific region. A key recommendation is opportunistic screening for people aged ≥65 years (all countries), with systematic screening to be considered for people aged ≥75 years or who have additional risk factors (all countries).
  4. Wijedasa LS, Jauhiainen J, Könönen M, Lampela M, Vasander H, Leblanc MC, et al.
    Glob Chang Biol, 2017 03;23(3):977-982.
    PMID: 27670948 DOI: 10.1111/gcb.13516
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links