Displaying publications 61 - 67 of 67 in total

Abstract:
Sort:
  1. Lee SV, Tai ES, Mutalib AR, Khairani-Bejo S, Bahaman AR
    Trop Biomed, 2011 Dec;28(3):497-505.
    PMID: 22433877 MyJurnal
    A simple and reliable tool for the early diagnosis of leptospirosis is urgently needed. We report the development of a lyophilized reagent-based polymerase chain reaction (PCR) assay targeting lipL32 gene, which is present only in pathogenic leptospires. To determine the effectiveness of the newly developed assay in the early diagnosis of leptospirosis, the sensitivity and specificity was evaluated. In simulated clinical samples, the assay was able to detect 10² and 10³ leptospires/ml in spiked urine and blood samples, respectively. In experimentally infected animals, leptospiral DNA could be detected in blood and lung samples as early as Day 1 post infection. This assay was also shown to be stable and remained sensitive for up to five months at ambient temperature. Hence, this lyophilized reagent-based PCR assay with high specificity, sensitivity and stability would provide a simple, rapid and reliable method in diagnosing acute leptospirosis, especially in the field of veterinary medicine.
    Matched MeSH terms: Reagent Kits, Diagnostic
  2. Situ SF, Ding CH, Nawi S, Johar A, Ramli R
    Malays J Pathol, 2017 Apr;39(1):25-31.
    PMID: 28413202 MyJurnal
    BACKGROUND: Chlamydia trachomatis and Neisseria gonorrhoeae are important bacterial pathogens of sexually transmitted infections (STIs) worldwide. This study sought to compare the analytical sensitivity and specificity of conventional methods against a rapid molecular method in detecting STIs caused by these bacteria.

    METHODS: Ninety five first-time male attendees of the Genito-urinary Medicine Clinic in Hospital Kuala Lumpur were included in this cross-sectional study. The detection of C. trachomatis was achieved through direct fluorescence antibody (DFA) staining of urethral swabs and real-time polymerase chain reaction testing (Xpert® CT/NG assay) on urine specimens. N. gonorrhoeae was detected through Gram staining and culture of urethral swabs and Xpert® CT/ NG assay on urine specimens.

    RESULTS: From the Xpert® CT/NG results, 11 (11.6%) attendees had chlamydia, 23 (24.2%) had gonorrhoea and 8 (8.4%) had both STIs. The sensitivity and specificity of DFA in detecting chlamydia compared to Xpert® CT/NG were 5.3% (95% CI: 0-28) and 94.7% (95% CI: 86-98), respectively. For gonorrhoea, the sensitivity and specificity of Gram staining were 90.3% (95% CI: 73-98) and 95.3% (86-99), respectively, whereas the sensitivity and specificity of culture compared to Xpert® CT/NG were 32.2% (95% CI: 17-51) and 100% (95% CI: 93-100), respectively.

    CONCLUSION: Although Gram-stained urethral swab smears are sensitive enough to be retained as a screening tool for gonorrhoea, culture as well as DFA lack sensitivity and are poorly suited to screen for gonorrhoea and chlamydia, respectively. However, owing to their high specificity, conventional detection methods are still suitable as confirmatory tests for gonorrhoea and chlamydia.

    Matched MeSH terms: Reagent Kits, Diagnostic
  3. Hussein NS, Sadiq SM, Kamaliah MD, Norakmal AW, Gohar MN
    Saudi J Kidney Dis Transpl, 2013 May;24(3):630-7.
    PMID: 23640651
    Urolithiasis is a common disease with increasing incidence and prevalence world-wide, probably more common in industrialized countries. The metabolic evaluation of 24-h urine collection has been considered as part of the management of urinary stone patients. The aim of this study was to evaluate the 24-h urine constituents in stone formers and its relation to demographic data in the northeast part of Peninsular Malaysia. One hundred and six patients were recruited in this study from two hospitals in the same geographical region; 96 patients fulfilled the inclusion criteria and an informed consent was obtained from all subjects. The 24-h urine was collected in sterile bottles with a preservative agent and calcium, oxalate, citrate, uric acid, magnesium and phosphate were tested using commercial kits on a Roche Hitachi 912 chemistry analyzer. The age (mean ± SD) of 96 patients was 56.45 ± 13.43 years and 82.3% of the patients were male while 17.7% were female. The 24-h urine abnormalities were hypercalciuria (14.5%), hyperoxaluria (61.4%), hypocitraturia (57.2%), hyperuricouria (19.7%), hypomagnesuria (59.3%) and hyperphosphaturia (12.5%). Hyperoxaluria (61.4%) was the most common abnormality detected during the analysis of 24-h urine constituents in contradiction to industrial countries, where hypercalciuria was the most common finding. The high frequencies of hypomagnesuria and hypocitraturia reflect the important role of magnesium and citrate in stone formation and their prophylactic role in the treatment of urinary stone disease in the given population.
    Matched MeSH terms: Reagent Kits, Diagnostic
  4. Saville M, Hawkes D, Keung M, Ip E, Silvers J, Sultana F, et al.
    J Clin Virol, 2020 06;127:104375.
    PMID: 32361328 DOI: 10.1016/j.jcv.2020.104375
    BACKGROUND: In the last decade, human papillomavirus (HPV) testing has been evaluated extensively for cervical screening, with studies finding increased sensitivity compared to cytology. Another advantage of HPV based-screening is the ability to test vaginal samples that can be collected by women themselves. Self-collection has the potential to extend cervical screening coverage by increasing participation rates, particularly among women who are under-screened or have never screened. This could have a significant impact on cervical cancer prevention, as the majority of invasive cervical cancer cases occur among under-screened women. Both the Netherlands and Australia have transitioned their national programs from cytology to HPV as the primary screening test and both countries include a pathway for self-collection.

    OBJECTIVES: We evaluated the relative sensitivity for HPV detection of self-collection compared with practitioner-collected cervical specimens in the context of the Australian National Cervical Screening Program (NCSP).

    STUDY DESIGN: 303 women aged ≥18 years attending a single tertiary referral centre took their own sample using a flocked-swab, and then had a practitioner-collected sample taken at colposcopy. All samples were tested at a single laboratory on the six PCR-based HPV assays which can be utilised in the NCSP; Roche cobas 4800 and cobas, Abbott RealTime, BD Onclarity, Cepheid Xpert, and Seegene Anyplex.

    RESULTS: HPV16/18 results had high observed agreement between self- and practitioner-collected samples on all assays (range: 0.94-0.99), with good agreement for non-HPV16/18 oncogenic HPV types (range: 0.64-0.73).

    CONCLUSIONS: Self-collection for HPV-based cervical screening shows good concordance and relative sensitivity when compared to practitionercollected samples across assays in the NCSP.

    Matched MeSH terms: Reagent Kits, Diagnostic
  5. Zeehaida M, Wan Nor Amilah WA, Amry AR, Hassan S, Sarimah A, Rahmah N
    Trop Biomed, 2008 Dec;25(3):209-16.
    PMID: 19287359
    Amoebic serodiagnosis at Hospital Universiti Sains Malaysia (HUSM), Kelantan employs an indirect haemagglutination assay (IHA) which detects anti-Entamoeba histolytica antibodies in patients' serum samples. In an amoebiasis endemic area such as Kelantan, interpretation of a positive IHA result can be problematic due to the high background antibody levels. The TechLab E. histolytica II ELISA is a commercial kit for detection of specific Gal/GalNAc lectin antigen in stool samples, and has been reported to be able to detect the antigen in serum samples from patients with amoebic liver abscess (ALA). Thus in this study we investigated the usefulness of TechLab E. histolytica II ELISA for diagnosis of ALA by comparing it with IHA. This is a cross sectional study involving 58 suspected ALA patients who were admitted to the surgical ward, HUSM, Kelantan. The diagnosis of ALA was established based on clinical symptoms and signs, ultrasound and/or CT scan results. The serum specimens obtained from the patients were tested with IHA (Dade Behring Diagnostics, Marburg, Germany) and TechLab E. histolytica II ELISA (Techlab, Blacksburg, Virginia, USA) according to the manufacturers' instructions. Of the 58 patients, 72.4% (42) were positive by IHA and only 8.6% (5) were positive by the TechLab E. histolytica II ELISA. Agreement between the IHA and ELISA was poor (kappa value 0.019, p=0.691). There was also no correlation between ELISA results and IHA antibody titers. The TechLab E. histolytica II ELISA was not sensitive in detecting amoebic antigen in samples from ALA patients. In addition the results of the test did not correlate with the IHA anti-E. histolytica antibody titres. Therefore, the TechLab E. histolytica II ELISA was found not to be useful for serological diagnosis of ALA at HUSM.
    Matched MeSH terms: Reagent Kits, Diagnostic
  6. Yatabe Y, Kerr KM, Utomo A, Rajadurai P, Tran VK, Du X, et al.
    J Thorac Oncol, 2015 Mar;10(3):438-45.
    PMID: 25376513 DOI: 10.1097/JTO.0000000000000422
    The efficacy of epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors in EGFR mutation-positive non-small-cell lung cancer (NSCLC) patients necessitates accurate, timely testing. Although EGFR mutation testing has been adopted by many laboratories in Asia, data are lacking on the proportion of NSCLC patients tested in each country, and the most commonly used testing methods.
    Matched MeSH terms: Reagent Kits, Diagnostic
  7. Loganathan R, Selvaduray KR, Nesaretnam K, Radhakrishnan AK
    Cell Prolif, 2013 Apr;46(2):203-13.
    PMID: 23510475 DOI: 10.1111/cpr.12014
    OBJECTIVES: Tocotrienols and tocopherols are members of the vitamin E family, with similar structures; however, only tocotrienols have been reported to achieve potent anti-cancer effects. The study described here has evaluated anti-cancer activity of vitamin E to elucidate mechanisms of cell death, using human breast cancer cells.

    MATERIALS AND METHODS: Anti-cancer activity of a tocotrienol-rich fraction (TRF) and a tocotrienol-enriched fraction (TEF) isolated from palm oil, as well as pure vitamin E analogues (α-tocopherol, α-, δ- and γ-tocotrienols) were studied using highly aggressive triple negative MDA-MB-231 cells and oestrogen-dependent MCF-7 cells, both of human breast cancer cell lines. Cell population growth was evaluated using a Coulter particle counter. Cell death mechanism, poly(ADP-ribose) polymerase cleavage and levels of NF-κB were determined using commercial ELISA kits.

    RESULTS: Tocotrienols exerted potent anti-proliferative effects on both types of cell by inducing apoptosis, the underlying mechanism of cell death being ascertained using respective IC50 concentrations of all test compounds. There was marked induction of apoptosis in both cell lines by tocotrienols compared to treatment with Paclitaxel, which was used as positive control. This activity was found to be associated with cleavage of poly(ADP-ribose) polymerase (a DNA repair protein), demonstrating involvement of the apoptotic cell death signalling pathway. Tocotrienols also inhibited expression of nuclear factor kappa-B (NF-κB), which in turn can increase sensitivity of cancer cells to apoptosis.

    CONCLUSION: Tocotrienols induced anti-proliferative and apoptotic effects in association with DNA fragmentation, poly(ADP-ribose) polymerase cleavage and NF-κB inhibition in the two human breast cancer cell lines.

    Matched MeSH terms: Reagent Kits, Diagnostic
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links