  1. Banjade DP, Tajuddin AA, Shukri A
    Appl Radiat Isot, 2001 Aug;55(2):235-43.
    PMID: 11393765
    Protocols developed for high-energy dosimetry IAEA (Technical Reports Series No. 277, 1997), AAPM (Med. Phys. 10 (1983) 741: Med. Phys. 18 (1991) 73: Med. Phys. 21 (1994) 1251), IPEMB (Phys. Med. Biol. 41 (1996) 2557), and HPA (Phys. Med. Biol. 28 (1983) 1097) have continued to enhance precision in dose measurements and the optimization of radiotherapy procedures. While recent dosimetry protocols, including those due to the IAEA and IPEMB, have made a number of improvements compared with previous protocols, it is further desirable to develop absolute dosimetry methods of dose measurements. Measurements based on careful implementation of procedures contained within the various protocols have been carried out in an effort to determine the extent to which discrepancies exist among the protocols. Dose in water at dmax was measured using cylindrical and parallel-plate ionization chambers for 6 MV photon beams and 5 and 12 MeV electron beams. Results obtained from the use of the AAPM and HPA protocols for 6 MV photon beams were found to be 0.9% larger and 0.1% smaller, respectively, than those measured following the IAEA protocol. Calibration dose measurements for 5 and 12 MeV electron beams in water phantoms were found to agree to within 1%, this being well within recommendations from the ICRU and other sources regarding the accuracy of dose delivery.
  2. Ashraf A, Saion E, Gharibshahi E, Kamari HM, Kong YC, Hamzah MS, et al.
    Appl Radiat Isot, 2016 Jan;107:17-23.
    PMID: 26405840 DOI: 10.1016/j.apradiso.2015.09.004
    A study was carried out on the concentration of REEs (Dy, Sm, Eu,Yb, Lu, La and Ce) that are present in the core marine sediments of East Malaysia from three locations at South China Sea and one location each at Sulu Sea and Sulawesi Sea. The sediment samples were collected at a depth of between 49 and 109 m, dried, and crushed to powdery form. The entire core sediments prepared for Instrumental Neutron Activation Analysis (INAA) were weighted approximately 0.0500 g to 0.1000 g for short irradiation and 0.1500 g to 0.2000 g for long irradiation. The samples were irradiated with a thermal neutron flux of 4.0×10(12) cm(-2) s(-1) in a TRIGA Mark II research reactor operated at 750 kW. Blank samples and standard reference materials SL-1 were also irradiated for calibration and quality control purposes. It was found that the concentration of REEs varies in the range from 0.11 to 36.84 mg/kg. The chondrite-normalized REEs for different stations suggest that all the REEs are from similar origins. There was no significant REEs contamination as the enrichment factors normalized for Fe fall in the range of 0.42-2.82.
  3. Ashraf A, Saion E, Gharibshahi E, Kamari HM, Yap CK, Hamzah MS, et al.
    Appl Radiat Isot, 2017 Apr;122:96-105.
    PMID: 28129589 DOI: 10.1016/j.apradiso.2017.01.006
    A study was carried out on the distribution and enrichment of trace elements in the core marine sediments of East Malaysia from three stations at South China Sea and one station each at Sulu Sea and Sulawesi Sea. Five stations of sediment cores were recovered and the vertical concentration profiles of six elements namely Br, Cs, Hf, Rb, Ta, and V were determined using the instrumental neutron activation analysis. The enrichment factor, geoaccumulation index and the modified degree of contamination were used to calculate the anthropogenic and pollution status of the elements in the samples. Except for Cs and Hf, which by the enrichment factor are categorized from minimum enrichment to moderate enrichment in all stations and for V and Rb in Sulu Sea and Sulawesi Sea, which are categorized minimum enrichment, other elements are found to be no enrichment at all stations. The geoaccumulation index of Hf in one station shows moderately polluted and for other elements are unpolluted. However, the modified degree values of all samples are less than 1, suggesting very low contamination of elements found in all the stations.
  4. Ashraf A, Saion E, Gharibshahi E, Yap CK, Kamari HM, Elias MS, et al.
    Appl Radiat Isot, 2018 Feb;132:222-231.
    PMID: 29183762 DOI: 10.1016/j.apradiso.2017.11.012
    Fifty-five core marine sediments from three locations at South China Sea and one location each at Sulu Sea and Sulawesi Sea of coastal East Malaysia were analyzed for heavy metals by instrumental neutron activation analysis and inductively coupled plasma mass spectroscopy. The enrichment factor and the modified degree of contamination were used to calculate the anthropogenic and pollution status of the elements in the samples. The enrichment factor of As, Cd, Cr, Cu, Ni, Pb, and Zn varied from 0.42-4.26, 0.50-2.34, 0.31-0.82, 0.20-0.61, 0.91-1.92, 0.23-1.52, and 0.90-1.28, respectively, with the modified degree of contamination values below 0.6. Comparative data showed that coastal East Malaysia has low levels of contamination.
  5. Ashhar Z, Ahmad Fadzil MF, Md Safee Z, Aziz F, Ibarhim UH, Nik Afinde NMF, et al.
    Appl Radiat Isot, 2024 Mar;205:111161.
    PMID: 38163386 DOI: 10.1016/j.apradiso.2023.111161
    Due to increased demand, cyclotron has an expanding role in producing Gallium-68 (68Ga) radiopharmaceuticals using solid and liquid targets. Though the liquid target produces lower end-of-bombardment activity compared to the solid target, our study presents the performance of 68Ga radiopharmaceuticals production using the liquid target by evaluating the end-of-bombardment activity and the end-of-purification activity of [68Ga]GaCl3. We also present the effect of increasing irradiation time, which significantly improves the end-of-synthesis yield. From the result obtained, the end-of-bombardment activity produced was 4.48 GBq, and the [68Ga]GaCl3 end-of-purification activity produced was 2.51 GBq with below-limit metallic impurities. Increasing the irradiation time showed a significant increase in the end-of-synthesis activity from 1.33 GBq to 1.95 GBq for [68Ga]Ga-PSMA-11 and from 1.13 GBq to 1.74 GBq for [68Ga]Ga-DOTA-TATE. Based on the improvements made, the liquid target production of 68Ga radiopharmaceuticals is feasible and reproducible to accommodate up to 5 patients per production. In addition, this work also discusses the issues encountered, together with the possible corrective and preventative measures.
  6. Asfahani J, Samuding K, Mostapa R, Othman O
    Appl Radiat Isot, 2021 Jan;167:109296.
    PMID: 33022484 DOI: 10.1016/j.apradiso.2020.109296
    Natural gamma ray well logging technique is used to characterize the radioactivity (GR) laterally and vertically in Banting district, SW of Malaysia. Seven drilled boreholes, along N-S profile with their natural gamma ray records are utilized to compute the heat production (HP) parameter, based on the Bucker and Rybach relationship.The analysis of 3467 measured points in those boreholes indicates that GR varies between 6.24 API and 358.4 API with an average of 79.95 API, while HP varies between 0.086 and 5.65 μw/m3 with an average of 1.25 μw/m3.The multi-fractal Concentration-Number (C-N) is used to characterize the radioactivity and heat production variations and to isolate different GR and HP populations in the study region. The high radioactivity and heat production ranges are mainly related to the silty clay layers, accompanied by uranium and thorium.
  7. Amrani D, Tahtat M
    Appl Radiat Isot, 2001 Apr;54(4):687-9.
    PMID: 11225705
    Samples of natural and manufactured building materials collected from Algiers have been analysed for 226Ra, 232Th and 40K using a high-resolution HPGe gamma-spectrometry system. The specific concentrations for 226Ra, 232Th and 40K, from the selected building materials, ranged from (12-65 Bq kg(-1)), (7-51 B qkg(-1)) and (36-675 Bq kg(-1)), respectively. The measured activity concentrations for these natural radionuclides were compared with the reported data of other countries and with the world average activity of soil. Radium-equivalent activities were calculated for the measured samples to assess the radiation hazards arising from using those materials in the construction of dwellings. All building materials showed Ra(eq) activities lower than the limit set in the OECD report (370 Bq kg(-1)), equivalent to external gamma-dose of 1.5 mSv yr(-1).
  8. Amin YM, Khandaker MU, Shyen AK, Mahat RH, Nor RM, Bradley DA
    Appl Radiat Isot, 2013 Oct;80:109-16.
    PMID: 23891979 DOI: 10.1016/j.apradiso.2013.06.014
    Current study concerns measurement of radioactivity levels in areas surrounding a 2420 MW thermal power plant fueled predominantly by bituminous coal. The concentrations of (226)Ra, (232)Th and (40)K in onsite bottom-ash were found to be 139 Bq/kg, 108 Bq/kg and 291 Bq/kg, respectively, the levels for these radiolnuclides in soil decreasing with distance from the power plant. At the plant perimeter the respective radionuclide concentrations were 87 Bq/kg, 74 Bq/kg and 297 Bq/kg. In a nearby town, the corresponding concentrations were 104 Bq/kg, 52 Bq/kg and 358 Bq/kg, suggestive of use of TENORM affected soils. The mean radium equivalent activities (Raeq) in soil and ash sample in the town were 205 Bq/kg and 316 Bq/kg, respectively. The Kapar plant ash/slag appears to contain a higher level of TENORM than the world average. The degree of contamination is much higher inside the town where slag has been mixed with topsoil as landfill or as simple domestic waste. For the prevailing levels of exposure and a worst case senario, the predicted committed effective dose due to ingestion and inhalation for intake durations of 1- and 30 years would be 4.2 μSv and 220 μSv, respectively.
  9. Alyahyawi A, Alanazi AH, Almurayshid M, Alshahri S, Almeshari M, Bradley DA
    Appl Radiat Isot, 2021 Dec;178:109953.
    PMID: 34560514 DOI: 10.1016/j.apradiso.2021.109953
    In respect of radiation exposure assessments, thermoluminescent dosimeters (TLD) represent a notable and important subset of passive detector technology, gaining widespread use over a period of many decades, not least for medical applications. TLDs are available in a range of physical and chemical forms, in particular the popularity of phosphor-based commercial products arising from features that include availability down to low mm dimensions, soft-tissue equivalence in some cases, and relatively low TL fading. Novel doped silica glass TL material fabricated as fibres also offer favourable responses, recent developments in co-doping leading to their ability to also provide for diagnostic radiology applications, adding to the attractive features of being impervious to water, of good sensitivity, and generally offering wide dynamic range. Thus said, doping and fibre fabrication involve relatively high costs. Accordingly, herein exploratory investigations are made of the cost-effective colourless silica-based glass medium from which marbles are made, reduced into chip form for ease of application, examining sensitivity to dose. In particular, the study focuses on the computerised tomography clinical application regime, 80- to 140 kVp, with excellent response being shown for doses within the range 2- to 50 mGy.
  10. Alyahyawi A, Jupp T, Alkhorayef M, Bradley DA
    Appl Radiat Isot, 2018 Aug;138:45-49.
    PMID: 28780202 DOI: 10.1016/j.apradiso.2017.07.011
    In the modern clinical practice of diagnostic radiology there is a growing demand for radiation dosimetry, it also being recognized that with increasing use of X-ray examinations additional population dose will result, accompanied by an additional albeit low potential for genetic consequences. At the doses typical of diagnostic radiology there is also a low statistical risk for cancer induction; in adhering to best practice, to be also implied is a low but non-negligible potential for deterministic sensitive organ responses, including in regard to the skin and eyes. Risk reduction is important, in line with the principle of ALARP, both in regard to staff and patients alike; for the latter modern practice is usually guided by Dose Reference Levels (DRL) while for the former and members of the public, legislated controls (supported by safe working practices) pertain. As such, effective, reliable and accurate means of dosimetry are required in support of these actions. Recent studies have shown that Ge-doped-silica glass fibres offer several advantages over the well-established phosphor-based TL dosimeters (TLD), including excellent sensitivity at diagnostic doses as demonstrated herein, low fading, good reproducibility and re-usability, as well as representing a water impervious, robust dosimetric system. In addition, these silica-based fibres show good linearity over a wide dynamic range of dose and dose-rate and are directionally independent. In the present study, we investigate tailor made doped-silica glass thermoluminescence (TL) for applications in medical diagnostic imaging dosimetry. The aim is to develop a dosimeter of sensitivity greater than that of the commonly used LiF (Mg,Ti) phosphor. We examine the ability of such doped glass media to detect the typically low levels of radiation in diagnostic applications (from fractions of a mGy through to several mGy or more), including, mammography and dental radiology, use being made of x-ray tubes located at the Royal Surrey County Hospital. We further examine dose-linearity, energy response and fading.
  11. Alsadig AA, Abbas S, Kandaiya S, Ashikin NARNN, Qaeed MA
    Appl Radiat Isot, 2017 Nov;129:130-134.
    PMID: 28843699 DOI: 10.1016/j.apradiso.2017.08.021
    Phantoms are devices that simulate human tissues including soft tissues, lungs, and bones in medical and health physics. The purpose of this work was to investigate the differential dose absorption in several commercially available low-cost materials as substitutes to human tissues using Gafchromic XR-QA2 film. The measurement of absorbed dose by different materials of various densities was made using the film to establish the relationship between the absorbed dose and the material density. Materials investigated included soft board materials, Perspex, chicken bone, Jeltrate, chalk, cow bone, marble, and aluminum, which have varying densities from 0.26 to 2.67gcm-3. The absorbed dose increased as the density and atomic number of the material increased. The absorbed dose to the density can be well represented by a polynomial function for the materials used.
  12. Alqahtani A, Sani SFA, Narissa NHA, Alanazi A, Podolyak Z, Nisbet A, et al.
    Appl Radiat Isot, 2020 Jun;160:109132.
    PMID: 32351224 DOI: 10.1016/j.apradiso.2020.109132
    As a result of the various evolving needs, thermoluminescence dosimetry is constantly under development, with applications intended in environmental and personal radiation monitoring through to the sensing of radiotherapy and radiation processing doses. In radiotherapy dosimetry challenges include small-field profile evaluation, encompassing the fine beams of radiosurgery, evaluations confronting the steep dose gradients of electronic brachytherapy and the high dose rates of FLASH radiotherapy. Current work concerns the thermoluminescent dosimetric properties of commercial low-cost borosilicate glass in the form of thin (sub-mm to a few mm) plates, use being made of microscope cover-slips irradiated using clinical external-beam radiotherapy facilities as well as through use of 60Co gamma irradiators. In using megavoltage photons and MeV electrons, characterization of the dosimetric response has been made for cover-slips of thicknesses up to 4 mm. Reproducibility to within +/5% has been obtained. In particular, for doses up to 10 Gy, the borosilicate cover-slips have been demonstrated to have considerable potential for use in high spatial resolution radiotherapy dosimetry, down to 0.13 mm in present work, with a coefficient of determination in respect of linearity of >0.99 for the thinner cover-slips. Results are also presented for 0.13- and 1.00-mm thick cover slips irradiated to 60Co gamma-ray doses, initially in the range 5- to 25 Gy, subsequently extended to 5 kGy-25 kGy, again providing linear response.
  13. Alnaaimi M, Sulieman A, Tamam N, Alkhorayef M, Alduaij M, Mohammedzein T, et al.
    Appl Radiat Isot, 2021 Dec;178:109965.
    PMID: 34688024 DOI: 10.1016/j.apradiso.2021.109965
    The positron emitters (18F-Sodium Fluoride (NaF)) and X-rays used in Positron emission tomography (PET) combined with computed tomography (PET/CT) imaging have a high radiation dose, which results in a high patient dose. The present research intends to determine the radiation dose and risks associated with PET/CT- 18F-Sodium fluoride examinations in patients. The 18F-NaF PET/CT was used to investigate the doses of 86 patients. Patient exposure parameters and ImPACT software were used to calculate mean effective doses. The administered activity of 185 MBq (5.0 mCi) per procedure has a mean and range based on the patient's BMI (BMI). The range of patient effective doses per procedure was found to be 4-10 mSv, with a radiation risk of 1 × 10-5 per procedure. Patient doses are determined by the patient's size, scanner type, imaging protocol, and reconstruction method. For further dose reduction, proper justification and radiation dose optimization is required.
  14. Almugren KS, Sani SFA, Wandira R, Wahib N, Rozaila ZS, Khandaker MU, et al.
    Appl Radiat Isot, 2019 Sep;151:102-110.
    PMID: 31163392 DOI: 10.1016/j.apradiso.2019.04.027
    Present research concerns the TL signal stored in chalk of the variety commercially available for writing on blackboards. Samples of this have been subjected to x-ray irradiation, the key dosimetric parameters investigated including dose and energy response, sensitivity, fading and glow curve analysis. Three types of chalk have been investigated, each in five different colours. The samples were annealed at 323 K prior to irradiation. For all three chalk types and all five colours, the dose response has been found linear over the investigated dose range, 0-9 Gy. Regardless of type or colour, photoelectric energy dependency is apparent at the low energy end down to the lowest investigated accelerating potential of 30 kV. Crayola (Yellow) has shown the greatest TL sensitivity, thus selection has been made to limit further analysis to this medium alone, specifically in respect of glow curve and fading study. In addition, elemental compositional and structural change characterizations were made for the same medium, utilizing Energy Dispersive X-Ray (EDX) and Raman spectroscopy, respectively.
  15. Almayahi BA, Tajuddin AA, Jaafar MS
    Appl Radiat Isot, 2012 Nov;70(11):2652-60.
    PMID: 22982603 DOI: 10.1016/j.apradiso.2012.07.021
    The radioactivity quantity and quality were determined in soil and water samples in Northern Malaysian Peninsula (NMP) using HPGe spectroscopy and GR-135 spectrometer. The (226)Ra, (232)Th and (40)K concentrations in soil samples are 57±2, 68±4 and 427±17 Bq kg(-1), respectively, whereas in water samples were found to be 2.86±0.79, 3.78±1.73 and 152±12 Bq l(-1), respectively. These concentrations are within those reported from literature in other countries in the world. The radiological hazard indices of the samples were also calculated. The mean values obtained from soil samples are 186 Bq kg(-1), 88 nGy h(-1), 108 μSv y(-1), 0.50 and 0.65 for Radium Equivalent Activity (Ra(eq)), Absorbed Dose Rates (D(R)), Annual Effective Dose Rates (ED), External Hazard Index (H(ex)) and Internal Hazard Index (H(in)) respectively, whereas, for water samples were found to be 20, 10, 13, 0.05 and 0.06, respectively. All the health hazard indices are well below their recommended limits, except in two soil sampling sites which were found to be (*)025 (1.1 H(ex)) and (*)026 (1.1 H(ex), 1.6 H(in)). The calculated and the measured gamma dose rates had a good correlation coefficient, R=0.88. Moreover, the average value radon is 20 (in the range of 7-64) Bq m(-3), a positive correlation (R=0.81) was observed between the (222)Rn and (226)Ra concentrations in samples measured by the SNC continuous radon monitor (model 1029, Sun Nuclear Corporation) and HPGe detector, respectively. Some soils in this study with H(in) and H(ex)<1 are suitable for use in agriculture and as building materials. Also, in this study H(in) and H(ex)<1 for water samples, therefore, water after processing and filtration is safe and suitable for use in household and industrial purposes.
  16. Alkhorayef M, Sulieman A, Alzahrani K, Abuzaid M, Alomair OI, Almuwannis M, et al.
    Appl Radiat Isot, 2021 Feb;168:109520.
    PMID: 33307438 DOI: 10.1016/j.apradiso.2020.109520
    The various technological advancements in computed tomography (CT) have resulted in remarkable growth in the use of CT imaging in clinical practice, not the least of which has been its establishment as the most valuable imaging examination for the assessment of cardiovascular system disorders. The objective of this study was to assess the effective radiation dose and radiation risk for patients during cardiac CT procedures, based on studies from four different hospitals equipped with 128 slice CT equipment. A total of eighty-three patients were investigated in this study with different clinical indications. Effective doses were also calculated using software based on Monte Carlo simulation. The mean patient age (years), weight (kg), and body mass index (BMI (kg/m2)) were 49 ± 11, 82 ± 12, and 31 ± 6, respectively. The results of the study revealed that the tube voltage (kVp) and tube current-exposure time product (mAs) ranged between 100 to 140 and 50 to 840 respectively. The overall average patient dose values for the volume CT dose index [(CTDIvol), in mGy)] and dose length product (DLP) (in mGy·cm) were 34.8 ± 15 (3.7-117.0) and 383.8 ± 354 (46.0-3277.0) respectively. The average effective dose (mSv) was 15.2 ± 8 (1.2-61.8). The radiation dose values showed wide variation between different hospitals and even within the same hospital. The results indicate the need to optimize radiation dose and to establish diagnostic reference levels (DRLs) for patients undergoing coronary computed tomography angiography (CCTA), also to harmonize the imaging protocols to ensure reduced radiation risk.
  17. Alkhorayef M, Sulieman A, Mohamed-Ahmed M, Al-Mohammed HI, Alkhomashi N, Sam AK, et al.
    Appl Radiat Isot, 2018 Nov;141:270-274.
    PMID: 30145016 DOI: 10.1016/j.apradiso.2018.07.014
    With associated cure rates in excess of 90%, targeted 131I radioactive iodine therapy has clearly improved thyroid cancer survival. Thus said, potential radiation risks to staff represent a particular concern, current study seeking to determine the radiation exposure of staff from 131I patients during hospitalization, also estimating accumulated dose and related risk to staff during preparation of the radioactive iodine. In present study made over the three-month period 1st February to 1st May 2017, a total of 69 patient treatments were investigated (comprising a cohort of 46 females and 23 males), this being a patient treatment load typically reflective of the workload at the particular centre for such treatments. The patients were administered sodium iodide 131I, retained in capsules containing activities ranging from 370 to 5550 MBq at the time of calibration, radioiodine activity depends on many factors such as gender, clinical indication, body mass index and age. The staff radiation dose arising from each patient treatment was measured on three consecutive days subsequent to capsule administration. In units of µSv, the mean and dose-rates range at distances from the patients of 5 cm, 1 m and 2 m were 209 ± 73 (165-294), 6.8 ± 2 (5.3-9.5) and 0.9 ± 0.3 (0.7-1.2). The annual dose (also measured in units of µSv), based on annual records of doses, for medical physicists, technologists and nurses were 604, 680 and 1000 µSv respectively. In regard to current practice and workload, staff exposures were all found to be below the annual dose limit for radiation workers.
  18. Alkhorayef M, Sulieman A, Babikir E, Daar E, Alnaaimi M, Alduaij M, et al.
    Appl Radiat Isot, 2018 Aug;138:14-17.
    PMID: 28830729 DOI: 10.1016/j.apradiso.2017.08.010
    A pacemaker, which is used for heart resynchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of pacemaker implantation procedures has increased to more than 50% worldwide. During this procedure, patients can be exposed to excessive radiation exposure. Wide range of doses has been reported in previous studies, suggesting that optimization of this procedure has not been fulfilled yet. The current study evaluated patient radiation exposure during cardiac pacemaker procedures and quantified the patient effective dose. A total of 145 procedures were performed for five pacemaker procedures (VVI, VVIR, VVD, VVDR, and DDDR) at two hospitals. Patient doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from the National Radiological Protection Board (NRPB, now The Health Protection Agency). The effective dose values were used to estimate cancer risk from the pacemaker procedure. Patient demographic data and exposure parameters for fluoroscopy and radiography were quantified. The mean patient doses ± SD per procedure (Gycm2) for VVI, VVIR, VVD, VVDR, and DDDR were 1.52 ± 0.13 (1.43-1.61), 3.28 ± 2.34 (0.29-8.73), 3.04 ± 1.67 (1.57-4.86), 6.04 ± 2.326 3.29-8.58), and 8.8 ± 3.6 (4.5-26.20), respectively. The overall patient effective dose was 1.1mSv per procedure. It is obvious that the DDDR procedure exposed patients to the highest radiation dose. Patient dose variation can be attributed to procedure type, exposure parameter settings, and fluoroscopy time. The results of this study showed that patient doses during different pacemaker procedures are lower compared to previous reported values. Patient risk from pacemaker procedure is low, compared to other cardiac interventional procedures. Patients' exposures were mainly influenced by the type of procedures and the clinical indication.
  19. Ali SKI, Khandaker MU, Al-Mugren KS, Latif SA, Bradley DA, Okhunov AA, et al.
    Appl Radiat Isot, 2021 Jul;173:109735.
    PMID: 33915407 DOI: 10.1016/j.apradiso.2021.109735
    Copper-67 (T1/2 = 61.83 h, Eβ-mean=141 keV, Iβ-total=100%; Eγ = 184.577 keV, Iγ = 48.7%) is a promising radionuclide for theranostic applications especially in radio immunotherapy. However, one of the main drawbacks for its application is related to its limited availability. Various nuclear reaction routes investigated in the last years can result in 67Cu production, although the use of proton beams is the method of choice taken into account in this work. The goal of this work is a revision of the cross-sections aimed at 67Cu yield, which were evaluated for the 68Zn(p,2p)67Cu reaction route up to 80 MeV proton energy. A well-defined statistical procedure, i.e., the Simultaneous Evaluation on KALMAN (SOK), combined with the least-squares concept, was used to obtain the evaluated data together with the covariance matrix. The obtained evaluated data were also compared to predictions provided by the nuclear reaction model codes TALYS and EMPIRE, and a partial agreement among them has been found. These data may be useful for both existing and potential applications in nuclear medicine, to achieve an improvement and validation of the various nuclear reaction models, and may also find applications in other fields (e.g., activation analysis and thin layer activation).
  20. Ali SKI, Khandaker MU, Kassim HA
    Appl Radiat Isot, 2018 May;135:239-250.
    PMID: 29448240 DOI: 10.1016/j.apradiso.2018.01.035
    186
    Re (T1/2= 89.24 h, [Formula: see text] 346.7 keV, [Formula: see text] ), an intense beta-emitter shows great potential to be used as an active material in therapeutic radiopharmaceuticals due to its suitable physico-chemical properties.186Re can be produced in several ways, however charged-particle induced reactions show to be promising towards no carrier added production. In this work, production cross-sections of186Re were evaluated following the light-charged particle induced reactions on tungsten. An effective evaluation technique such as Simultaneous Evaluation on KALMAN code combined with least squares concept was used to obtain the evaluated data together with covariances. Knowledge of the underlying uncertainties in evaluated nuclear data, i.e., covariances are useful to improve the accuracy of nuclear data.