Displaying publications 161 - 169 of 169 in total

Abstract:
Sort:
  1. Mehboob H, Tarlochan F, Mehboob A, Chang SH, Ramesh S, Harun WSW, et al.
    J Mater Sci Mater Med, 2020 Aug 20;31(9):78.
    PMID: 32816091 DOI: 10.1007/s10856-020-06420-7
    The current study is proposing a design envelope for porous Ti-6Al-4V alloy femoral stems to survive under fatigue loads. Numerical computational analysis of these stems with a body-centered-cube (BCC) structure is conducted in ABAQUS. Femoral stems without shell and with various outer dense shell thicknesses (0.5, 1.0, 1.5, and 2 mm) and inner cores (porosities of 90, 77, 63, 47, 30, and 18%) are analyzed. A design space (envelope) is derived by using stem stiffnesses close to that of the femur bone, maximum fatigue stresses of 0.3σys in the porous part, and endurance limits of the dense part of the stems. The Soderberg approach is successfully employed to compute the factor of safety Nf > 1.1. Fully porous stems without dense shells are concluded to fail under fatigue load. It is thus safe to use the porous stems with a shell thickness of 1.5 and 2 mm for all porosities (18-90%), 1 mm shell with 18 and 30% porosities, and 0.5 mm shell with 18% porosity. The reduction in stress shielding was achieved by 28%. Porous stems incorporated BCC structures with dense shells and beads were successfully printed.
    Matched MeSH terms: Prosthesis Design
  2. Pirouzi G, Abu Osman NA, Ali S, Davoodi Makinejad M
    Proc Inst Mech Eng H, 2017 Dec;231(12):1127-1132.
    PMID: 28985696 DOI: 10.1177/0954411917735082
    Prosthetic alignment is an essential process to rehabilitate patients with amputations. This study presents, for the first time, an invented device to read and record prosthesis alignment data. The digital device consists of seven main parts: the trigger, internal shaft, shell, sensor adjustment button, digital display, sliding shell, and tip. The alignment data were read and recorded by the user or a computer to replicate prosthesis adjustment for future use or examine the sequence of changes in alignment and its effect on the posture of the patient. Alignment data were recorded at the anterior/posterior and medial/lateral positions for five patients. Results show the high level of confidence to record alignment data and replicate adjustments. Therefore, the device helps patients readjust their prosthesis by themselves, or prosthetists to perform adjustment for patients and analyze the effects of malalignment.
    Matched MeSH terms: Prosthesis Design
  3. Gholizadeh H, Abu Osman NA, Lúvíksdóttir Á, Eshraghi A, Kamyab M, Wan Abas WA
    Prosthet Orthot Int, 2011 Dec;35(4):360-4.
    PMID: 21975850 DOI: 10.1177/0309364611423130
    Good suspension lessens the pistoning (vertical displacement) of the residual limb inside the prosthetic socket. Several methods are used for measuring the pistoning.
    Matched MeSH terms: Prosthesis Design/instrumentation*; Prosthesis Design/methods*
  4. Haider KG, Lewis GR
    Quintessence Int, 1994 Jan;25(1):23-6.
    PMID: 8190877
    A variety of problems faces the prosthodontist attempting reconstruction of maxillary defects. There are various treatment options for patients requiring a partial maxillectomy and an obturator prosthesis. Reduced adaptability makes it difficult for the patient to learn to use a new appliance, unless existing skills can be employed. It is therefore helpful to reproduce familiar features of a patient's existing obturator, especially if this has been used successfully over a transition period.
    Matched MeSH terms: Prosthesis Design; Dental Prosthesis Design/methods*
  5. Gholizadeh H, Abu Osman NA, Eshraghi A, Arifin N, Chung TY
    Prosthet Orthot Int, 2016 Aug;40(4):509-16.
    PMID: 25583929 DOI: 10.1177/0309364614564022
    BACKGROUND: This article describes a total surface bearing prosthetic socket for a patient (25-year-old female) with a bulbous stump.

    CASE DESCRIPTION AND METHODS: The subject had unstable excessive soft tissue at the distal end of the residuum. After 2 years of prosthetic use, she experienced several problems, including pain in the residual limb and knee joint. Pressure distribution was evaluated during ambulation. We also designed a total surface bearing socket with Velcro as suspension system to distribute the load evenly on the residual limb, and to facilitate donning procedure.

    FINDINGS AND OUTCOMES: The main site of weight bearing in the old prosthesis (patellar tendon bearing) was anterior proximal region of the residual limb, especially the patellar tendon. The pressure was almost 10 times higher than the distal region during level walking. Pressures were distributed more evenly with the total surface bearing socket design, and the donning was much easier.

    CONCLUSION: Pressure distribution within the socket could be affected by socket design and suspension system. Using the total surface bearing socket and Velcro as suspension system might facilitate donning of prosthesis and reduce traction at the end of residual limb during the swing phase of gait.

    CLINICAL RELEVANCE: Proper socket design and suspension system based on the amputees' need can facilitate rehabilitation process and lead to the amputee's satisfaction. The pressure is distributed more uniformly over the residual limb by the total surface bearing socket compared to the patellar tendon bearing socket for lower limb amputees with unusual stump shape.

    Matched MeSH terms: Prosthesis Design*
  6. Lui JL
    Dent Traumatol, 2001 Oct;17(5):227-30.
    PMID: 11678543
    The composite reinforcement technique has been used clinically to salvage damaged root-filled teeth compromised by caries, trauma, developmental abnormalities, internal resorption and iatrogenic causes. This clinical case report describes the use of the technique to reattach a fractured fragment in a compromised endodontically treated root besides reinforcing it for continued function in the mouth. Factors of clinical importance related to this additional application; including reattachment of tooth fragments, post crown retention, coronal microleakage and fracture resistance and strength, are also briefly discussed.
    Matched MeSH terms: Dental Prosthesis Design
  7. Shankargouda SB, Sidhu P, Kardalkar S, Desai PM
    J Prosthodont, 2017 Feb;26(2):168-171.
    PMID: 26479878 DOI: 10.1111/jopr.12385
    Residual ridge resorption is a rapid, progressive, irreversible, and inevitable process of bone resorption. Long-standing teeth and implants have been shown to have maintained the bone around them without resorption. Thus, overdenture therapy has been proven to be beneficial in situations where few remaining teeth are present. In addition to the various advantages seen with tooth-supported telescopic overdentures, a few shortcomings can also be expected, including unseating of the overdenture, increased bulk of the prosthesis, secondary caries, etc. The precise transfer of the secondary telescopic copings to maintain the spatial relationship, without any micromovement, remains the most critical step in ensuring the success of the tooth-supported telescopic prosthesis. Thus, a simple and innovative technique of splinting the secondary copings was devised to prevent distortion and micromovement and maintain its spatial relationship.
    Matched MeSH terms: Dental Prosthesis Design*
  8. Chandrasekhar J, Kalkman DN, Aquino MB, Sartori S, Hájek P, Atzev B, et al.
    Int J Cardiol, 2020 05 15;307:17-23.
    PMID: 32111358 DOI: 10.1016/j.ijcard.2020.01.045
    BACKGROUND: The COMBO drug-eluting stent combines sirolimus-elution from a biodegradable polymer with an anti-CD34+ antibody coating for early endothelialization.

    OBJECTIVE: We investigated for geographical differences in outcomes after percutaneous coronary intervention (PCI) with the COMBO stent among Asians and Europeans.

    METHODS: The COMBO Collaboration is a pooled patient-level analysis of the MASCOT and REMEDEE registries of all-comers undergoing attempted COMBO stent PCI. The primary outcome was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (TV-MI) and target lesion revascularization (TLR).

    RESULTS: This study included 604 Asians (17.9%) and 2775 Europeans (82.1%). Asians were younger and included fewer females, with a higher prevalence of diabetes mellitus but lower prevalence of other comorbidities than Europeans. Asians had a higher prevalence of ACC/AHA C type lesions and received longer stent lengths. More Asians than Europeans were discharged on clopidogrel (86.5% vs 62.8%) rather than potent P2Y12 inhibitors. One-year TLF occurred in 4.0% Asians and 4.1% of Europeans, p = 0.93. The incidence of cardiac death was higher in Asians (2.8% vs. 1.3%, p = 0.007) with similar rates of TV-MI (1.5% vs. 1.2%, p = 0.54) and definite stent thrombosis (0.3% vs. 0.5%, p = 0.84) and lower incidence of TLR than Europeans (1.0% vs. 2.5%, p = 0.025). After adjustment, differences for cardiac death and TLR were no longer significant.

    CONCLUSIONS: In the COMBO collaboration, although 1-year TLF was similar regardless of geography, Asians experienced higher rates of cardiac death and lower TLR than Europeans, while incidence of TV-MI and ST was similar in both regions. Adjusted differences did not reach statistical significance. CLINICALTRIAL.

    GOV IDENTIFIER-NUMBERS: NCT01874002 (REMEDEE Registry), NCT02183454 (MASCOT registry).

    Matched MeSH terms: Prosthesis Design
  9. Chandrasekhar J, Zeebregts D, Kalkman DN, Sartori S, Roumeliotis A, Aquino MB, et al.
    Cardiovasc Revasc Med, 2020 12;21(12):1542-1547.
    PMID: 32507695 DOI: 10.1016/j.carrev.2020.05.002
    BACKGROUND: Small vessel diameter is associated with higher risk of target lesion revascularization (TLR) after percutaneous coronary intervention (PCI). The COMBO sirolimus-eluting biodegradable-polymer stent has a proprietary anti-CD34 antibody layer to enhance homogeneous endothelialization, which may be advantageous in treating small vessels.

    OBJECTIVE: We examined for differences in 1-year clinical outcomes after PCI by maximum implanted stent diameter from the COMBO collaboration.

    METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset of patients undergoing PCI with COMBO stents in the MASCOT and REMEDEE multicenter registries. Stent diameter was available in 3590 (99.3%) patients. We compared patients receiving COMBO stents <3 mm versus ≥3 mm. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI) or clinically driven TLR. Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods.

    RESULTS: The study included 792 (22%) patients with small stents <3 mm and 2798 (78%) patients with large stents ≥3 mm. Small stent patients included more women with lower body mass index and higher prevalence of diabetes but similar prevalence of acute coronary syndrome. Risk of 1-year TLF was similar in small and large stent groups (4.4% vs. 3.8%, HR 1.12, 95% CI 0.74-1.72, p = 0.58). There were no differences in the rates of cardiac death (1.7% vs. 1.5%, p = 0.74), TV-MI (1.4% vs. 1.2%, p = 0.58) or TLR (2.7% vs. 2.1%, p = 0.31). Definite or probable ST occurred in 1.3% of the small stent and 0.7% of the large stent PCI patients, p = 0.14, HR 2.13, 95% CI 0.93-5.00, p = 0.07.

    CONCLUSIONS: One-year ischemic outcomes after COMBO PCI were similar irrespective of stent diameter in this all-comers international cohort.

    Matched MeSH terms: Prosthesis Design
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links