Displaying all 3 publications

Abstract:
Sort:
  1. Alshishani A, Salhimi SM, Saad B
    PMID: 29241085 DOI: 10.1016/j.jchromb.2017.12.013
    A new salting-out assisted liquid-liquid extraction (SALLE) sample preparation method for the determination of the polar anti-diabetic biguanide drugs (metformin, buformin and phenformin) in blood plasma, urine and lake water samples were developed. The SALLE was performed by mixing samples (plasma (0.2mL), urine or lake water (1.0mL)) with acetonitrile (0.4mL for plasma, 0.5mL for urine or lake water), sodium hydroxide powder was then added for the phase separation. The effects of type of salting-out reagent, type of extraction solvent, volumes of acetonitrile and sample, amount of sodium hydroxide, vortexing and centrifugation times on the extraction efficiency were investigated. The upper layer, containing the biguanides, was directly injected into a HPLC unit using ZIC-HILIC column (150mm×2.1mm×3.5μm) and was detected at 236nm. The method was validated and calibration curves were linear with r2>0.99 over the range of 20-2000μgL-1for plasma and 5-2000μgL-1for urine and lake water samples. The limits of detection were in the range (3.8-5.6)μgL-1, (0.8-1.5)μgL-1and (0.3-0.8)μgL-1for plasma, urine and lake water, respectively. The accuracies in the three matrices were within 87.3-103%, 87.4-109%, 82.2-109% of the nominal concentration for metformin, buformin and phenformin, respectively. The relative standard deviation for inter- and intra -day precision were in the range of 1.0-17% for all analytes in the three matrices.
  2. Sazali NH, Alshishani A, Saad B, Chew KY, Chong MM, Miskam M
    R Soc Open Sci, 2019 Aug;6(8):190952.
    PMID: 31598260 DOI: 10.1098/rsos.190952
    In this study, salting-out assisted liquid-liquid extraction (SALLE) as a simple and efficient extraction technique followed by high-performance liquid chromatography (HPLC) was employed for the determination of vitamin D3 in milk samples. The sample treatment is based on the use of water-miscible acetonitrile as the extractant and acetonitrile phase separation under high-salt conditions. Under the optimum conditions, acetonitrile and ammonium sulfate were used as the extraction solvent and salting-out agent, respectively. The vitamin D3 extract was separated using Hypersil ODS (250x i.d 4.6 mm, 5 µm) HPLC column that was coupled with diode array detector. Vitamin D2 was used as internal standard (IS) to offset any variations in chromatographic conditions. The vitamin D3 and the IS were eluted in 18 min. Good linearity (r2 > 0.99) was obtained within the range of 25-600 ng g-1 with the limit of detection of 15 ng g-1 and limit of quantification of 25 ng g-1. The validated method was applied for the determination of vitamin D3 in milk samples. The recoveries for spiked samples were from 94.4 to 113.5%.
  3. Alshishani A, Makahleh A, Yap HF, Gubartallah EA, Salhimi SM, Saad B
    Talanta, 2016 Dec 01;161:398-404.
    PMID: 27769423 DOI: 10.1016/j.talanta.2016.08.067
    A new sample preparation method, ion-pair vortex assisted liquid-liquid microextraction (VALLME-BE), for the determination of a highly polar anti-diabetic drug (metformin) in plasma sample was developed. The VALLME-BE was performed by diluting the plasma in borate buffer and extracted to 150µL 1-octanol containing 0.2M di-(2-ethylhexyl)phosphoric acid as intermediate phase. The drug was next back-extracted into 20µL of 0.075M HCl solution. The effects of pH, ion-pair concentration, type of organic solvent, volume of extraction phases, ionic strength, vortexing and centrifugation times on the extraction efficiency were investigated. The optimum conditions were at pH 9.3, 60s vortexing and 2min centrifugation. The microextract, contained metformin and buformin (internal standard), was directly injected into a HPLC unit using C1 column (250mm×4.6mm×10µm) and detected at 235nm. The method was validated and calibration curve was linear with r2>0.99 over the range of 20-2000µgL-1. The limits of detection and quantitation were 1.4 and 4.1µgL-1, respectively. The accuracy was within 94.8-108% of the nominal concentration. The relative standard deviation for inter- and intra-day precision was less than 10.8%. The method was conveniently applied for the determination of metformin in plasma samples.