Displaying all 3 publications

Abstract:
Sort:
  1. Azizan A, Büchs J
    J Biol Eng, 2017;11:28.
    PMID: 28785308 DOI: 10.1186/s13036-017-0070-7
    BACKGROUND: Biotechnological development in shake flask necessitates vital engineering parameters e.g. volumetric power input, mixing time, gas liquid mass transfer coefficient, hydromechanical stress and effective shear rate. Determination and optimization of these parameters through experiments are labor-intensive and time-consuming. Computational Fluid Dynamics (CFD) provides the ability to predict and validate these parameters in bioprocess engineering. This work provides ample experimental data which are easily accessible for future validations to represent the hydrodynamics of the fluid flow in the shake flask.

    RESULTS: A non-invasive measuring technique using an optical fluorescence method was developed for shake flasks containing a fluorescent solution with a waterlike viscosity at varying filling volume (VL = 15 to 40 mL) and shaking frequency (n = 150 to 450 rpm) at a constant shaking diameter (do = 25 mm). The method detected the leading edge (LB) and tail of the rotating bulk liquid (TB) relative to the direction of the centrifugal acceleration at varying circumferential heights from the base of the shake flask. The determined LB and TB points were translated into three-dimensional (3D) circumferential liquid distribution plots. The maximum liquid height (Hmax) of the bulk liquid increased with increasing filling volume and shaking frequency of the shaking flask, as expected. The toroidal shapes of LB and TB are clearly asymmetrical and the measured TB differed by the elongation of the liquid particularly towards the torus part of the shake flask.

    CONCLUSION: The 3D liquid distribution data collected at varying filling volume and shaking frequency, comprising of LB and TB values relative to the direction of the centrifugal acceleration are essential for validating future numerical solutions using CFD to predict vital engineering parameters in shake flask.

  2. Azizan A, Sieben M, Wandrey G, Büchs J
    Biotechnol Bioeng, 2019 11;116(11):2983-2995.
    PMID: 31350917 DOI: 10.1002/bit.27132
    Shake flasks are still the most relevant experimental tool in the development of viscous fermentation processes. The phase number, which defines the onset of the unfavorable out-of-phase (OP) phenomenon in shake flasks, was previously defined via specific power input measurements. In the OP state, the bulk liquid no longer follows the orbital movement of the imposed centrifugal force, which is for example, detrimental to oxygen transfer. In this study, an optical fluorescence technique was used to measure the three-dimensional liquid distribution in shake flasks. Four new optically derived evaluation criteria for the phase transition between the in-phase and OP condition were established: (a) thickness of the liquid film left on the glass wall by the rotating bulk liquid, (b) relative slope of the leading edge of bulk liquid (LB) lines, (c) trend of the angular position of LB, and (d) very high angular position of the leading edge. In contrast to the previously applied power input measurements, the new optical evaluation criteria describe the phase transition in greater detailed. Instead of Ph = 1.26, a less conservative value of Ph = 0.91 is now suggested for the phase transfer, which implies a broader operating window for shake flask cultivations with higher viscosities.
  3. Dinter C, Gumprecht A, Menze MA, Azizan A, Niehoff PJ, Hansen S, et al.
    Sci Rep, 2024 Feb 13;14(1):3658.
    PMID: 38351095 DOI: 10.1038/s41598-024-53980-7
    Computational fluid dynamics (CFD) has recently become a pivotal tool in the design and scale-up of bioprocesses. While CFD has been extensively utilized for stirred tank reactors (STRs), there exists a relatively limited body of literature focusing on CFD applications for shake flasks, almost exclusively concentrated on fluids at waterlike viscosity. The importance of CFD model validation cannot be overstated. While techniques to elucidate the internal flow field are necessary for model validation in STRs, the liquid distribution, caused by the orbital shaking motion of shake flasks, can be exploited for model validation. An OpenFOAM CFD model for shake flasks has been established. Calculated liquid distributions were compared to suitable, previously published experimental data. Across a broad range of shaking conditions, at waterlike and moderate viscosity (16.7 mPa∙s), the CFD model's liquid distributions align excellently with the experimental data, in terms of overall shape and position of the liquid relative to the direction of the centrifugal force. Additionally, the CFD model was used to calculate the volumetric power input, based on the energy dissipation. Depending on the shaking conditions, the computed volumetric power inputs range from 0.1 to 7 kW/m3 and differed on average by 0.01 kW/m3 from measured literature data.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links