Displaying all 5 publications

Abstract:
Sort:
  1. Chan PWK, Norzila MZ, Bilkis AA, Mazidad A
    Med J Malaysia, 2002 Dec;57(4):482-6.
    PMID: 12733174
    Accessibility of research done locally to clinicians remains limited unless it is in the published form. The publication rate of research presentations at the Annual Malaysian Paediatric Association, Perinatal Society of Malaysia and Academy of Medicine Malaysia in 1997 and 1998 was determined. One hundred and five (95.5%) of 110 research presentations were carried out in Malaysia. Thirty-seven (35.2%) presentations were published. University-affiliated institutions were more likely to publish their research presentations as compared to Ministry of Health hospitals (OR 3.1 95% CI 1.4-6.8, p < 0.01). There is a need to encourage publication of local research presentations. University-affiliated institutions performed better due to institution pressure for career advancement.
  2. Boo NY, Mohd-Amin I, Bilkis AA, Yong-Junina F
    Singapore Med J, 2006 Sep;47(9):763-8.
    PMID: 16924357
    Introduction: The aim of this study was to determine predictors of failed closure of patent ductus arteriosus (PDA) following a single course of indomethacin in symptomatic preterm infants.
    Methods: This prospective observational study was carried out on 60 preterm infants weighing less than 1,750 g with symptomatic PDA confirmed by echocardiography. At a median age of 7.0 days (interquartile range 4.0), they were given indomethacin of 0.1 mg/kg/day intravenously daily for six days. Closure of PDA was reassessed by echocardiography upon completion of therapy.
    Results: The PDA of 40 percent (n=24) of these infants remained patent. Forward logistic regression analysis showed that the only significant predictors of failed PDA closure in these infants were: PDA size (adjusted odds-ratio [OR] is 7.0; 95 percent confidence interval [CI] of OR is 2.0, 24.8; p-value is 0.002), birth weight (adjusted OR is 0.996; 95 percent CI of OR is 0.993, 1.000; p-value is 0.03) and platelet count (adjusted OR is 0.987; 95 percent CI is 0.975, 1.000; p-value is 0.045). Gestational age, maternal age and left atrium/aorta ratios were not significant predictors.
    Conclusion: Larger PDA, lower birth weight and lower platelet count were significant predictors of high failure in indomethacin therapy given late at one week of life.
  3. Chelliah KK, Faizah MZ, Dayang AA, Bilkis AA, Shareena I, Mazli M
    Case Rep Radiol, 2012;2012:564036.
    PMID: 22792503 DOI: 10.1155/2012/564036
    Conjoined twins are rare and present a unique challenge to pediatric surgeons and radiologists. An imaging strategy to accurately define anatomic fusion, vascular anomalies, and other associated abnormalities is important for surgical planning and prognostic information. A conjoined female twin with a combined weight of 2.8 kg was born by emergency caeserean. Hence, a computed tomography scan of the thorax and entire abdomen at 1.25 mm slice thickness was performed to delineate the internal structures of the twins. CT-angiography defined specific vascular supply which determined the distribution of shared structures between the twins. An echocardiogram showed four heart chambers with atrioventricular septal defect. To further evaluate the heart chambers, the twin was planned for gated cardiac magnetic resonance imaging. Unfortunately, they succumbed 6 hours apart due to complication of septicemia. Magnetic resonance imaging and CT scan provide excellent anatomic detail, demonstrating organ position, shared viscera, and limited vascular anatomy, whilst angiography defined specific vascular supply, useful in determining the distribution of shared structures between the twins in planning for surgery.
  4. Alwi M, Geetha K, Bilkis AA, Lim MK, Hasri S, Haifa AL, et al.
    J Am Coll Cardiol, 2000 Feb;35(2):468-76.
    PMID: 10676696
    We compared the result of radiofrequency (RF)-assisted valvotomy and balloon dilation with closed surgical valvotomy and Blalock Taussig (BT) shunt as primary treatment in selected patients with pulmonary atresia and intact ventricular septum (PA-IVS).
  5. Bilkis AA, Alwi M, Hasri S, Haifa AL, Geetha K, Rehman MA, et al.
    J Am Coll Cardiol, 2001 Jan;37(1):258-61.
    PMID: 11153748 DOI: 10.1016/s0735-1097(00)01094-9
    Objectives: The aim of the study was to assess the safety and efficacy of the Amplatzer ductal occluder (ADO) in transcatheter occlusion of patent ductus arteriosus (PDA).
    Background: Transcatheter closure of small to moderate sized PDAs is an established procedure. The ADO is a self-expandable device with a number of salutary features, notably its retrievability, ease of delivery via small 5F to 7F catheters and a range of sizes suitable even for the larger PDAs.
    Methods: Between November 1997 and August 1999, the ADO was successfully implanted in 205 of 209 patients with PDA. The inclusion criteria for this device occlusion method were patients with clinical and echocardiographic features of moderate to large PDA, weighing > or =3.5 kg as well as asymptomatic adolescents and adults with PDA measuring > or =5.0 mm on two-dimensional (2D) echocardiogram. Occlusion was achieved via the antegrade venous approach. Follow-up evaluations were performed with 2D echocardiogram, color-flow mapping and Doppler measurement of the descending aorta and left pulmonary artery velocity at 24 h and 1, 3, 6 and 12 months after implantation.
    Results: Two hundred and five patients had successful PDA occlusion using this device. The patients were between two months and 50 years (median 1.9) and weighed between 3.4 kg and 63.2 (median 8.4). Infants made up 26% of the total patients. The PDA measured from 1.8 to 12.5 mm (mean 4.9) at the narrowest diameter. Forty-four percent of patients achieved immediate complete occlusion. On color Doppler the closure rates at 24 h and 1 month after implant were 66% and 97%, respectively. At 6 and 12 months all except one patient attained complete occlusion. Device embolization occurred in three patients; in two this was spontaneous, and in the other it was due to catheter manipulation during postimplant hemodynamic measurement. Mild aortic narrowing was seen in an infant.
    Conclusions: Patent ductus arteriosus occlusion using ADO is safe and efficacious. It is particularly useful in symptomatic infants and small children with relatively large PDA. Embolization can be minimized by selection of appropriate sized devices, and caution should be exercised in infants <5 kg.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links