Displaying all 6 publications

Abstract:
Sort:
  1. Chandrasekhar J, Zeebregts D, Kalkman DN, Sartori S, Roumeliotis A, Aquino MB, et al.
    Cardiovasc Revasc Med, 2020 12;21(12):1542-1547.
    PMID: 32507695 DOI: 10.1016/j.carrev.2020.05.002
    BACKGROUND: Small vessel diameter is associated with higher risk of target lesion revascularization (TLR) after percutaneous coronary intervention (PCI). The COMBO sirolimus-eluting biodegradable-polymer stent has a proprietary anti-CD34 antibody layer to enhance homogeneous endothelialization, which may be advantageous in treating small vessels.

    OBJECTIVE: We examined for differences in 1-year clinical outcomes after PCI by maximum implanted stent diameter from the COMBO collaboration.

    METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset of patients undergoing PCI with COMBO stents in the MASCOT and REMEDEE multicenter registries. Stent diameter was available in 3590 (99.3%) patients. We compared patients receiving COMBO stents <3 mm versus ≥3 mm. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI) or clinically driven TLR. Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods.

    RESULTS: The study included 792 (22%) patients with small stents <3 mm and 2798 (78%) patients with large stents ≥3 mm. Small stent patients included more women with lower body mass index and higher prevalence of diabetes but similar prevalence of acute coronary syndrome. Risk of 1-year TLF was similar in small and large stent groups (4.4% vs. 3.8%, HR 1.12, 95% CI 0.74-1.72, p = 0.58). There were no differences in the rates of cardiac death (1.7% vs. 1.5%, p = 0.74), TV-MI (1.4% vs. 1.2%, p = 0.58) or TLR (2.7% vs. 2.1%, p = 0.31). Definite or probable ST occurred in 1.3% of the small stent and 0.7% of the large stent PCI patients, p = 0.14, HR 2.13, 95% CI 0.93-5.00, p = 0.07.

    CONCLUSIONS: One-year ischemic outcomes after COMBO PCI were similar irrespective of stent diameter in this all-comers international cohort.

  2. Chandrasekhar J, Kalkman DN, Aquino MB, Sartori S, Hájek P, Atzev B, et al.
    Int J Cardiol, 2020 05 15;307:17-23.
    PMID: 32111358 DOI: 10.1016/j.ijcard.2020.01.045
    BACKGROUND: The COMBO drug-eluting stent combines sirolimus-elution from a biodegradable polymer with an anti-CD34+ antibody coating for early endothelialization.

    OBJECTIVE: We investigated for geographical differences in outcomes after percutaneous coronary intervention (PCI) with the COMBO stent among Asians and Europeans.

    METHODS: The COMBO Collaboration is a pooled patient-level analysis of the MASCOT and REMEDEE registries of all-comers undergoing attempted COMBO stent PCI. The primary outcome was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (TV-MI) and target lesion revascularization (TLR).

    RESULTS: This study included 604 Asians (17.9%) and 2775 Europeans (82.1%). Asians were younger and included fewer females, with a higher prevalence of diabetes mellitus but lower prevalence of other comorbidities than Europeans. Asians had a higher prevalence of ACC/AHA C type lesions and received longer stent lengths. More Asians than Europeans were discharged on clopidogrel (86.5% vs 62.8%) rather than potent P2Y12 inhibitors. One-year TLF occurred in 4.0% Asians and 4.1% of Europeans, p = 0.93. The incidence of cardiac death was higher in Asians (2.8% vs. 1.3%, p = 0.007) with similar rates of TV-MI (1.5% vs. 1.2%, p = 0.54) and definite stent thrombosis (0.3% vs. 0.5%, p = 0.84) and lower incidence of TLR than Europeans (1.0% vs. 2.5%, p = 0.025). After adjustment, differences for cardiac death and TLR were no longer significant.

    CONCLUSIONS: In the COMBO collaboration, although 1-year TLF was similar regardless of geography, Asians experienced higher rates of cardiac death and lower TLR than Europeans, while incidence of TV-MI and ST was similar in both regions. Adjusted differences did not reach statistical significance. CLINICALTRIAL.

    GOV IDENTIFIER-NUMBERS: NCT01874002 (REMEDEE Registry), NCT02183454 (MASCOT registry).

  3. Chandrasekhar J, de Winter VC, Kalkman DN, Sartori S, Chandiramani R, Aquino MB, et al.
    Cardiovasc Drugs Ther, 2021 04;35(2):309-320.
    PMID: 33515411 DOI: 10.1007/s10557-020-07087-6
    PURPOSE: The COMBO biodegradable polymer sirolimus-eluting stent includes endothelial progenitor cell capture (EPC) technology for rapid endothelialization, which may offer advantage in acute coronary syndromes (ACS). We sought to analyze the performance of the COMBO stent by ACS status and ACS subtype.

    METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset from the MASCOT and REMEDEE registries. We evaluated outcomes by ACS status, and ACS subtype in patients with ST segment elevation myocardial infarction (STEMI) or non-STEMI (NSTEMI) versus unstable angina (UA). The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Secondary outcomes included stent thrombosis (ST).

    RESULTS: We compared 1965 (54%) ACS and 1649 (46.0%) non-ACS patients. ACS presentations included 40% (n = 789) STEMI, 31% (n = 600) NSTEMI, and 29% (n = 576) UA patients. Risk of 1-year TLF was greater in ACS patients (4.5% vs. 3.3%, HR 1.51 95% CI 1.01-2.25, p = 0.045) without significant differences in definite/probable ST (1.1% vs 0.5%, HR 2.40, 95% CI 0.91-6.31, p = 0.08). One-year TLF was similar in STEMI, NSTEMI, and UA (4.8% vs 4.8% vs. 3.7%, p = 0.60), but definite/probable ST was higher in STEMI patients (1.9% vs 0.5% vs 0.7%, p = 0.03). Adjusted outcomes were not different in MI versus UA patients.

    CONCLUSIONS: Despite the novel EPC capture technology, COMBO stent PCI was associated with somewhat greater risk of 1-year TLF in ACS than in non-ACS patients, without significant differences in stent thrombosis. No differences were observed in 1-year TLF among ACS subtypes.

  4. Chandrasekhar J, Kerkmeijer LS, Kalkman DN, Sartori S, Aquino MB, Woudstra P, et al.
    Catheter Cardiovasc Interv, 2021 04 01;97(5):797-804.
    PMID: 32198837 DOI: 10.1002/ccd.28853
    BACKGROUND: The COMBO drug eluting stent is a novel device with luminal endothelial progenitor cell capture technology for rapid homogeneous endothelialization.

    METHODS AND RESULTS: We examined for sex differences in 1-year outcomes after COMBO stenting from the COMBO collaboration, a pooled patient-level dataset from the MASCOT and REMEDEE multicenter registries. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI), or clinically driven target lesion revascularization (CD-TLR). Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods. The study included 861 (23.8%) women and 2,753 (76.2%) men. Women were older with higher prevalence of several comorbidities including diabetes mellitus. Risk of 1-year TLF was similar in both sexes (3.8% vs. 3.9%, HR 0.92, 95% CI 0.59-1.42, p = .70), without sex differences in the incidence of cardiac death (1.6% vs. 1.5%, p = .78), TV-MI (1.5% vs. 1.1%, p = .32), or CD-TLR (2.0% vs. 2.2%, p = .67). Definite or probable ST occurred in 0.4% women and 1.0% men (HR 0.26, 95% CI 0.06-1.11, p = .069).

    CONCLUSIONS: Despite greater clinical risks at baseline, women treated with COMBO stents had similarly low 1-year TLF and other ischemic outcomes compared to men.

  5. Chandrasekhar J, Sartori S, Aquino MB, Baber U, Hájek P, Atzev B, et al.
    Am J Cardiol, 2020 07 15;127:1-8.
    PMID: 32418717 DOI: 10.1016/j.amjcard.2020.04.014
    Older patients who undergo coronary interventions are at greater risk of ischemic events and less likely to tolerate prolonged dual antiplatelet therapy (DAPT) due to bleeding risk. The COMBO biodegradable polymer sirolimus-eluting stent promotes rapid endothelialization through endothelial progenitor cell capture technology which may be advantageous in elderly patients. We compared 1-year clinical outcomes and DAPT cessation events in patients >75 versus ≤75 years from the MASCOT registry. MASCOT was a prospective, multicenter cohort study of all-comers undergoing attempted COMBO stenting. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, myocardial infarction (MI) not clearly attributed to a nontarget vessel or clinically driven target lesion revascularization. Bleeding was adjudicated using the Bleeding Academic Research Consortium criteria. Adjusted outcomes were analyzed using Cox regression methods. The study included 18% (n = 479) patients >75 years and 72% (n = 2,135) patients ≤75 years. One-year TLF occurred in 4.6% patients >75 years versus 3.1% patients ≤75years of age, p = 0.10; adj hazard ratio 1.36, 95% confidence intervals 0.77 to 2.38, p = 0.29. There were no significant differences in cardiac death (1.7% vs 1.3%, p = 0.55), MI (2.1% vs 1.2%, p = 0.14), target lesion revascularization (1.7% vs 1.4%, p = 0.60) and definite stent thrombosis (0.8% vs 0.4%, p = 0.19). Major Bleeding Academic Research Consortium 3,5 bleeding (3.1% vs 1.5%, p = 0.01) and DAPT cessation rates (32.4% vs 23.0%, p <0.001) were significantly higher in elderly patients. In conclusion, elderly patients >75 years treated with COMBO stents had similar TLF but significantly greater incidence of bleeding than younger patients and DAPT cessation in one-third of patients over 1 year.
  6. Chandrasekhar J, Baber U, Sartori S, Aquino MB, Hájek P, Atzev B, et al.
    Int J Cardiol Heart Vasc, 2020 Dec;31:100605.
    PMID: 32953969 DOI: 10.1016/j.ijcha.2020.100605
    Background: The COMBO stent is a biodegradable-polymer sirolimus-eluting stent with endothelial progenitor cell capture technology for faster endothelialization.

    Objective: We analyzed COMBO stent outcomes in relation to bleeding risk using the PARIS bleeding score.

    Methods: MASCOT was an international registry of all-comers undergoing attempted COMBO stent implantation. We stratified patients as low bleeding-risk (LBR) for PARIS score ≤ 3 and intermediate-to-high (IHBR) for score > 3 based on baseline age, body mass index, anemia, current smoking, chronic kidney disease and need for triple therapy. Primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, myocardial infarction (MI) not clearly attributed to a non-target vessel or clinically-driven target lesion revascularization (TLR). Bleeding was adjudicated using the Bleeding Academic Research Consortium (BARC) definition. Dual antiplatelet therapy (DAPT) cessation was independently adjudicated.

    Results: The study included 56% (n = 1270) LBR and 44% (n = 1009) IHBR patients. Incidence of 1-year TLF was higher in IHBR patients (4.1% vs. 2.6%, p = 0.047) driven by cardiac death (1.7% vs. 0.7%, p = 0.029) with similar rates of MI (1.8% vs. 1.1%, p = 0.17), TLR (1.5% vs. 1.6%, p = 0.89) and definite/ probable stent thrombosis (1.2% vs. 0.6%, p = 0.16). Incidence of 1-year major BARC 3 or 5 bleeding was significantly higher in IHBR patients (2.3% vs. 0.9%, p = 0.0094), as was the incidence of DAPT cessation (29.3% vs. 22.8%, p 

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links