PURPOSE: To evaluate the prevalence of ocular surface disease (OSD) in glaucoma and nonglaucoma subjects using different clinical tests and to determine the effect of number of antiglaucoma medications and preservatives on OSD.
METHODS: This is a cross-sectional, case-comparison study at the Eye Clinic of the University of Malaya Medical Centre, Malaysia, between June 2012 and January 2013. Glaucoma subjects (n = 105) using topical antiglaucoma medications were compared with control subjects (n = 102) who were not on any topical medications. The presence of OSD was assessed using the tear film breakup time (TBUT) test, corneal staining, Schirmer test, and Ocular Surface Disease Index (OSDI) questionnaire grading.
RESULTS: The prevalence of OSD varied from 37 to 91% in the glaucoma group, depending on the type of clinical test. More subjects in the glaucoma group had corneal staining (63% vs. 36%, p = 0.004), abnormal Schirmer tests (39% vs. 25%, p = 0.049), and moderate OSDI symptoms (17% vs. 7%, p = 0.028). The percentage with abnormal TBUT increased with higher numbers of topical medications and was high with both benzalkonium chloride-containing and preservative-free eye drops (90% and 94%, respectively, both p < 0.001). Benzalkonium chloride was associated with a nearly three times higher odds ratio of showing abnormal OSDI.
CONCLUSIONS: Ocular surface disease is common in those using topical antiglaucoma medications. Abnormal TBUT is associated with increasing number of eye drops and benzalkonium chloride-containing eye drops, although this also occurs with the use of preservative-free eye drops.
Study site: Eye Clinic, University of Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia,
To determine the accuracy of intraocular lens (IOL) calculations in eyes undergoing phacoemulsification cataract surgery with IOL implantation using immersion A-scan ultrasound (US) and Lenstar LS 900(®) biometry. In this prospective study, 200 eyes of 200 patients were randomized to undergo either Lenstar LS 900(®) or immersion A-scan US biometry to determine the IOL dioptric power prior to phacoemulsification cataract surgery. Post-operative refractive outcomes of these two groups of patients were compared. The result showed no significant difference between the target spherical equivalent (SE) and the post-operative SE value by the Lenstar LS 900(®) (p value = 0.632) or immersion A-scan US biometry (p value = 0.438) devices. The magnitude of difference between the two biometric devices were not significantly different (p value = 0.868). There was no significant difference in the predicted post-operative refractive outcome between immersion A-scan US biometry and Lenstar LS 900(®). Based on the results, the immersion A-scan US technique is as accurate as Lenstar LS 900(®) in the hands of an experienced operator.